메뉴 건너뛰기




Volumn 25, Issue 2, 2009, Pages 201-204

Breath-hold target localization with simultaneous kilovoltage/megavoltage cone-beam CT and fast reconstruction

Author keywords

Cone beam CT; Fast tomographic reconstruction; Image guided radiotherapy; Kilovoltage megavoltage imaging; Treatment verification

Indexed keywords

BIOMEDICAL ENGINEERING; DIAGNOSIS; LINEAR ACCELERATORS; MEDICAL IMAGING; MEDICAL PHYSICS; RADIOTHERAPY;

EID: 77950882538     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03879-2_57     Document Type: Conference Paper
Times cited : (1)

References (10)
  • 1
    • 34248329093 scopus 로고    scopus 로고
    • Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms
    • Dobler B, Walter C, Knopf A et al. (2006) Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms. Radiat Oncol 1(4)
    • (2006) Radiat Oncol , vol.1 , pp. 4
    • Dobler, B.1    Walter, C.2    Knopf, A.3
  • 2
    • 0034212293 scopus 로고    scopus 로고
    • Set-up error in radiotherapy: On-line correction using electronic kilovoltage and megavoltage radiographs
    • Pisani LJ, Lockman D, Jaffray DA et al. (2000) Set-up error in radiotherapy: On-line correction using electronic kilovoltage and megavoltage radiographs. Int J Radiat Oncol Biol Phys 47(3):825-839
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , Issue.3 , pp. 825-839
    • Pisani, L.J.1    Lockman, D.2    Jaffray, D.A.3
  • 3
    • 34547828780 scopus 로고    scopus 로고
    • Four-dimensional treatment planning for stereotactic body radiotherapy
    • Guckenberger M, Wilbert J, Krieger T et al. (2007) Four-dimensional treatment planning for stereotactic body radiotherapy. Int J Radiat Oncol Biol Phys 69(1):276-285
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , Issue.1 , pp. 276-285
    • Guckenberger, M.1    Wilbert, J.2    Krieger, T.3
  • 4
    • 39749101847 scopus 로고    scopus 로고
    • Accuracy of ultrasound-based (BAT) prostate-repositioning: A three-dimensional on-line fiducial-based assessment with cone-beam computed tomography
    • Boda-Heggemann J, Koehler FM, Kuepper B et al. (2008) Accuracy of ultrasound-based (BAT) prostate-repositioning: a three-dimensional on-line fiducial-based assessment with cone-beam computed tomography. Int J Radiat Oncol Biol Phys 70(4):1247-1255
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , Issue.4 , pp. 1247-1255
    • Boda-Heggemann, J.1    Koehler, F.M.2    Kuepper, B.3
  • 5
    • 33646000817 scopus 로고    scopus 로고
    • Digital tomosynthesis with an on-board kilovoltage imaging device
    • Godfrey DJ, Yin FF, Oldham M at al. (2006) Digital tomosynthesis with an on-board kilovoltage imaging device. Int J Radiat Oncol Biol Phys 65(1):8-15
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , Issue.1 , pp. 8-15
    • Godfrey, D.J.1    Yin, F.F.2    Oldham, M.3
  • 6
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image guided radiation therapy
    • Jaffray DA, Siewertsen JH, Wong JW et al. (2002) Flat-panel cone-beam computed tomography for image guided radiation therapy. Int J Radiat Oncol Biol Phys 53(5):1337-1349
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , Issue.5 , pp. 1337-1349
    • Jaffray, D.A.1    Siewertsen, J.H.2    Wong, J.W.3
  • 8
    • 25644448237 scopus 로고    scopus 로고
    • A technique for on-board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification
    • Yin FF, Guan H and Lu W (2005) A technique for on-board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification. Med. Phys. 32(9):2819-2826
    • (2005) Med. Phys. , vol.32 , Issue.9 , pp. 2819-2826
    • Yin, F.F.1    Guan, H.2    Lu, W.3
  • 9
    • 33744823315 scopus 로고    scopus 로고
    • Patient dose from kilovoltage cone beam computed tomograhpy imaging in radiation therapy
    • Islam MK, Purdie TG, Norrlinger BD et al. (2006) Patient dose from kilovoltage cone beam computed tomograhpy imaging in radiation therapy. Med Phys 33(6):1573-1582
    • (2006) Med Phys , vol.33 , Issue.6 , pp. 1573-1582
    • Islam, M.K.1    Purdie, T.G.2    Norrlinger, B.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.