메뉴 건너뛰기




Volumn 31, Issue 4, 2010, Pages 838-844

Single breath-hold assessment of ventricular volumes using 32-channel coil technology and an extracellular contrast agent

Author keywords

32 channel coil; 3D imaging; Ventricular volumes; Whole heart imaging

Indexed keywords

GADOLINIUM PENTETATE; CONTRAST MEDIUM;

EID: 77950874456     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22061     Document Type: Article
Times cited : (14)

References (19)
  • 2
    • 0035088021 scopus 로고    scopus 로고
    • MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
    • Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF. MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 2001;219:264-269. (Pubitemid 32234085)
    • (2001) Radiology , vol.219 , Issue.1 , pp. 264-269
    • Barkhausen, J.1    Ruehm, S.G.2    Goyen, M.3    Buck, T.4    Laub, G.5    Debatin, J.F.6
  • 3
    • 0033301605 scopus 로고    scopus 로고
    • Normal human right and left ventricular mass, systolic function and gender differences by cine magnetic resonance imaging
    • Lorenz CH, Walker ES, Morgan VL, Klein SS, Graham TP. Normal human right and left ventricular mass, systolic function and gender differences by cine magnetic resonance imaging. J Cardiovasc Magn Reson 1999;1:7-21.
    • (1999) J Cardiovasc Magn Reson , vol.1 , pp. 7-21
    • Lorenz, C.H.1    Walker, E.S.2    Morgan, V.L.3    Klein, S.S.4    Graham, T.P.5
  • 4
    • 0037373294 scopus 로고    scopus 로고
    • Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    • DOI 10.1002/jmri.10262
    • Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU. Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 2003;17:323-329. (Pubitemid 36259246)
    • (2003) Journal of Magnetic Resonance Imaging , vol.17 , Issue.3 , pp. 323-329
    • Alfakih, K.1    Plein, S.2    Thiele, H.3    Jones, T.4    Ridgway, J.P.5    Sivananthan, M.U.6
  • 5
    • 0038787546 scopus 로고    scopus 로고
    • Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging
    • DOI 10.1002/jmri.10329
    • Alfakih K, Plein S, Bloomer T, Jones T, Ridgway J, Sivananthan M. Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging. J Magn Reson Imaging 2003;18:25-32. (Pubitemid 36791265)
    • (2003) Journal of Magnetic Resonance Imaging , vol.18 , Issue.1 , pp. 25-32
    • Alfakih, K.1    Plein, S.2    Bloomer, T.3    Jones, T.4    Ridgway, J.5    Sivananthan, M.6
  • 6
    • 0036104746 scopus 로고    scopus 로고
    • Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    • Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ. Breath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility. Radiology 2002;223:789-797.
    • (2002) Radiology , vol.223 , pp. 789-797
    • Moon, J.C.1    Lorenz, C.H.2    Francis, J.M.3    Smith, G.C.4    Pennell, D.J.5
  • 7
    • 51449123206 scopus 로고    scopus 로고
    • Prospective self-gating for simultaneous compensation of cardiac and respiratory motion
    • Buehrer M, Curcic J, Boesiger P, Kozerke S. Prospective self-gating for simultaneous compensation of cardiac and respiratory motion. Magn Reson Med 2008;60:683-690.
    • (2008) Magn Reson Med , vol.60 , pp. 683-690
    • Buehrer, M.1    Curcic, J.2    Boesiger, P.3    Kozerke, S.4
  • 10
    • 84866094429 scopus 로고    scopus 로고
    • Single breath-hold 3D cine imaging of the Heart: A non-angulated isotrpoic acquisition using SENSE on a 32 channel system
    • Muthurangu V, Noble N, Boubertakh R, et al. Single breath-hold 3D cine imaging of the Heart: a non-angulated isotrpoic acquisition using SENSE on a 32 channel system. In: Proc 14th Annual Meeting ISMRM, Seattle; 2006:330.
    • Proc 14th Annual Meeting ISMRM, Seattle; 2006 , vol.330
    • Muthurangu, V.1    Noble, N.2    Boubertakh, R.3
  • 11
    • 47049093531 scopus 로고    scopus 로고
    • Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE
    • Maredia N, Kozerke S, Larghat A, et al. Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE. J Cardiovasc Magn Reson 2008;10:27.
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 27
    • Maredia, N.1    Kozerke, S.2    Larghat, A.3
  • 14
    • 42949107448 scopus 로고    scopus 로고
    • Single-breathhold four-dimensional assessment of left ventricular volumes and function using k-t BLAST after application of extracellular contrast agent at 3 Tesla
    • DOI 10.1002/jmri.21332
    • Hamdan A, Kelle S, Schnackenburg B, Wellnhofer E, Fleck E, Nagel E. Single-breathhold four-dimensional assessment of left ventricular volumes and function using k-t BLAST after application of extracellular contrast agent at 3 Tesla. J Magn Reson Imaging 2008;27:1028-1036. (Pubitemid 351614613)
    • (2008) Journal of Magnetic Resonance Imaging , vol.27 , Issue.5 , pp. 1028-1036
    • Hamdan, A.1    Kelle, S.2    Schnackenburg, B.3    Wellnhofer, E.4    Fleck, E.5    Nagel, E.6
  • 16
    • 0030966347 scopus 로고    scopus 로고
    • Comparison of respiratory suppression methods and navigator locations for MR coronary angiography
    • McConnell MV, Khasgiwala VC, Savord BJ, et al. Comparison of respiratory suppression methods and navigator locations for MR coronary angiography. AJR Am J Roentgenol 1997;168:1369-1375.
    • (1997) AJR Am J Roentgenol , vol.168 , pp. 1369-1375
    • McConnell, M.V.1    Khasgiwala, V.C.2    Savord, B.J.3
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-311.
    • (1986) Lancet , vol.1 , pp. 307-311
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 34247282700 scopus 로고    scopus 로고
    • Prognostic value of cardiac magnetic resonance stress tests: Adenosine stress perfusion and dobutamine stress wall motion imaging
    • DOI 10.1161/CIRCULATIONAHA.106.652016
    • Jahnke C, Nagel E, Gebker R, et al. Prognostic value of cardiac magnetic resonance stress tests: adenosine stress perfusion and dobutamine stress wall motion imaging. Circulation 2007;115:1769-1776. (Pubitemid 46648614)
    • (2007) Circulation , vol.115 , Issue.13 , pp. 1769-1776
    • Jahnke, C.1    Nagel, E.2    Gebker, R.3    Kokocinski, T.4    Kelle, S.5    Manka, R.6    Fleck, E.7    Paetsch, I.8
  • 19
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • DOI 10.1002/mrm.21391
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007;58:1182-1195. (Pubitemid 350234205)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.