메뉴 건너뛰기




Volumn 20, Issue 2, 2010, Pages 533-540

A long wavelength excitable fluorophore; Chloro Phenyl Imino Propenyl Aniline (CPIPA) for selective sensing of Hg (II)

Author keywords

Hg(II) sensing; Mercury sensor; Optical chemical sensor; Spectrofluorometry

Indexed keywords

ALKALINE EARTH; AQUEOUS SOLUTIONS; ASSOCIATION CONSTANT; COMPLEX FORMATIONS; DETECTION LIMITS; EMISSION WAVELENGTH; FLOWTHROUGH; FLUORESCENCE QUANTUM YIELD; FLUOROIONOPHORES; LONG WAVELENGTH; MERCURY ION; OPTICAL CHEMICAL SENSOR; OPTICAL CHEMICAL SENSORS; OPTODES; PLASTICIZED PVC; SELECTIVE SENSING; SENSING SCHEMES; SENSOR MEMBRANES; SOLID MATRIXES; SPECTROFLUOROMETRY; WORKING RANGE;

EID: 77950859436     PISSN: 10530509     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10895-009-0577-5     Document Type: Article
Times cited : (18)

References (23)
  • 1
    • 0033957758 scopus 로고    scopus 로고
    • Determination of mercury in environmental and biological samples using pyrolysis atomic absorption spectrometry with gold amalgamation
    • DOI 10.1016/S0003-2670(99)00742-4, PII S0003267099007424
    • CT Costley KF Mossop JR Dean LM Garden J Marshall J Carroll 2000 Determination of mercury in environmental and biological samples using pyrolysis atomic absorption spectrometry with gold amalgamation Anal Chim Acta 405 179 183 10.1016/S0003-2670(99)00742-4 1:CAS:528:DC%2BD3cXhtVajsbs%3D (Pubitemid 30017899)
    • (2000) Analytica Chimica Acta , vol.405 , Issue.1-2 , pp. 179-183
    • Costley, C.T.1    Mossop, K.F.2    Dean, J.R.3    Garden, L.M.4    Marshall, J.5    Carroll, J.6
  • 2
    • 0031420372 scopus 로고    scopus 로고
    • Trace determination of mercury: A review
    • 10.1080/10408349708050578 1:CAS:528:DyaK2sXjtVGjtLk%3D
    • WL Clevenger BW Smith JD Winefordner 1997 Trace determination of mercury: a review Crit Rev Anal Chem 27 1 26 10.1080/10408349708050578 1:CAS:528:DyaK2sXjtVGjtLk%3D
    • (1997) Crit Rev Anal Chem , vol.27 , pp. 1-26
    • Clevenger, W.L.1    Smith, B.W.2    Winefordner, J.D.3
  • 3
    • 4043169759 scopus 로고    scopus 로고
    • 2+ in aqueous media at nanomolar levels employing a squaraine-based reporter
    • 10.1021/ic049422q 1:CAS:528:DC%2BD2cXlvFGjurY%3D 15310190
    • 2+ in aqueous media at nanomolar levels employing a squaraine-based reporter Inorg Chem 43 17 5183 10.1021/ic049422q 1:CAS:528:DC%2BD2cXlvFGjurY%3D 15310190
    • (2004) Inorg Chem , vol.43 , Issue.17 , pp. 5183
    • Ros-Lis, J.V.1    Martinez, R.2    Rurack, K.3    Sancenon, F.4    Soto, J.5    Spieles, M.6
  • 4
    • 43949094179 scopus 로고    scopus 로고
    • Oligonucleotide-based fluorescence probe for sensitive and selective detection of mercury(II) in aqueous solution
    • DOI 10.1021/ac800142k
    • CK Chiang CC Huang CW Liu HT Chang 2008 Oligonucleotide-based fluorescence probe for sensitive and selective detection of mercury(II) in aqueous solution Anal Chem 80 10 3716 3721 10.1021/ac800142k 1:CAS:528:DC%2BD1cXlslOisrs%3D 18363331 (Pubitemid 351705872)
    • (2008) Analytical Chemistry , vol.80 , Issue.10 , pp. 3716-3721
    • Chiang, C.-K.1    Huang, C.-C.2    Liu, C.-W.3    Chang, H.-T.4
  • 5
    • 12044257615 scopus 로고
    • Bulk optodes based on neutral dithiocarbamate ionophores with high selectivity and sensitivity for silver and mercury cations
    • 10.1021/ac00082a019 1:CAS:528:DyaK2cXkvFymsr0%3D
    • M Lerchi E Reitter W Simon B Pretsch DA Chowdhury S Kamata 1994 Bulk optodes based on neutral dithiocarbamate ionophores with high selectivity and sensitivity for silver and mercury cations Anal Chem 66 1713 1717 10.1021/ac00082a019 1:CAS:528:DyaK2cXkvFymsr0%3D
    • (1994) Anal Chem , vol.66 , pp. 1713-1717
    • Lerchi, M.1    Reitter, E.2    Simon, W.3    Pretsch, B.4    Chowdhury, D.A.5    Kamata, S.6
  • 6
    • 0031084690 scopus 로고    scopus 로고
    • Fluorescence-based sensor membrane for mercury (II) detection
    • 10.1016/S0925-4005(97)80212-2
    • I Murkovic OS Wolfbeis 1997 Fluorescence-based sensor membrane for mercury (II) detection Sens Actuators B 39 246 251 10.1016/S0925-4005(97)80212-2
    • (1997) Sens Actuators B , vol.39 , pp. 246-251
    • Murkovic, I.1    Wolfbeis, O.S.2
  • 7
    • 33847779054 scopus 로고    scopus 로고
    • Bis(2-pyridyl)-substituted boratriazaindacene as an NIR-emitting chemosensor for Hg (II)
    • 10.1021/ol062867t 1:CAS:528:DC%2BD2sXptFOgtA%3D%3D 17256867
    • A Coskun MD Yilmaz EU Akkaya 2007 Bis(2-pyridyl)-substituted boratriazaindacene as an NIR-emitting chemosensor for Hg (II) Org Lett 9 607 609 10.1021/ol062867t 1:CAS:528:DC%2BD2sXptFOgtA%3D%3D 17256867
    • (2007) Org Lett , vol.9 , pp. 607-609
    • Coskun, A.1    Yilmaz, M.D.2    Akkaya, E.U.3
  • 8
    • 33845520471 scopus 로고    scopus 로고
    • Selective gold-nanoparticle-based "turn-on" fluorescent sensors for detection of mercury(II) in aqueous solution
    • DOI 10.1021/ac061487i
    • CC Huang HT Chang 2006 Selective gold-nanoparticle-based Turn-On fluorescent sensors for detection of mercury (II) in aqueous solution Anal Chem 78 8332 8338 10.1021/ac061487i 1:CAS:528:DC%2BD28XhtFynurzK 17165824 (Pubitemid 44927608)
    • (2006) Analytical Chemistry , vol.78 , Issue.24 , pp. 8332-8338
    • Huang, C.-C.1    Chang, H.-T.2
  • 9
    • 33750991078 scopus 로고    scopus 로고
    • Signal ratio amplification via modulation of resonance energy transfer: Proof of principle in an emission ratiometric Hg(II) sensor
    • DOI 10.1021/ja066144g
    • A Coskun EU Akkaya 2006 Signal ratio amplification via modulation of resonance energy transfer: proof of principle in a novel emission ratiometric Hg(II) sensor J Am Chem Soc 128 14474 14475 10.1021/ja066144g 1:CAS:528:DC%2BD28XhtFSrs7%2FO 17090027 (Pubitemid 44749843)
    • (2006) Journal of the American Chemical Society , vol.128 , Issue.45 , pp. 14474-14475
    • Coskun, A.1    Akkaya, E.U.2
  • 10
    • 60249095920 scopus 로고    scopus 로고
    • An optical sensor for mercury ion based on the fluorescence quenching of tetra(p-dimethylaminophenyl)porphyrin
    • 10.1016/j.aca.2009.01.038 1:CAS:528:DC%2BD1MXitlGgsLo%3D 19231360
    • Y Yang J Jiang G Shen R Yu 2009 An optical sensor for mercury ion based on the fluorescence quenching of tetra(p-dimethylaminophenyl)porphyrin Anal Chim Acta 636 83 88 10.1016/j.aca.2009.01.038 1:CAS:528:DC%2BD1MXitlGgsLo%3D 19231360
    • (2009) Anal Chim Acta , vol.636 , pp. 83-88
    • Yang, Y.1    Jiang, J.2    Shen, G.3    Yu, R.4
  • 11
    • 33748311977 scopus 로고    scopus 로고
    • An organically modified sol-gel membrane for detection of mercury ions by using 5,10,15,20-tetraphenylporphyrin as a fluorescence indicator
    • DOI 10.1016/j.snb.2005.12.009, PII S0925400505009615
    • L Guo W Zhang Z Xie X Lin G Chen 2006 An organically modified sol-gel membrane for detection of mercury ions by using 5, 10, 15, 20- tetraphenylporphyrin as a fluorescence indicator Sens Actuators B 119 209 214 10.1016/j.snb.2005.12.009 (Pubitemid 44332061)
    • (2006) Sensors and Actuators, B: Chemical , vol.119 , Issue.1 , pp. 209-214
    • Guo, L.1    Zhang, W.2    Xie, Z.3    Lin, X.4    Chen, G.5
  • 12
    • 0035871735 scopus 로고    scopus 로고
    • Selective pool optode for mercury ion sensing in aqueous solution
    • DOI 10.1016/S0925-4005(00)00722-X, PII S092540050000722X
    • B Kuswandi R Narayanaswamy 2001 Selective pool optode for mercury ion sensing in aqueous solution Sens Actuators B 74 131 137 10.1016/S0925-4005(00) 00722-X (Pubitemid 32287953)
    • (2001) Sensors and Actuators, B: Chemical , vol.74 , Issue.1-3 , pp. 131-137
    • Kuswandi, B.1    Narayanaswamy, R.2
  • 13
    • 34248588106 scopus 로고    scopus 로고
    • Turn-on and ratiometric mercury sensing in water with a red-emitting probe
    • DOI 10.1021/ja068879r
    • EM Nolan SJ Lippard 2007 Turn-on and ratiometric mercury sensing in water with a red-emitting probe J Am Chem Soc 129 5910 5918 10.1021/ja068879r 1:CAS:528:DC%2BD2sXktVygsL4%3D 17429971 (Pubitemid 46748496)
    • (2007) Journal of the American Chemical Society , vol.129 , Issue.18 , pp. 5910-5918
    • Nolan, E.M.1    Lippard, S.J.2
  • 14
    • 57949091021 scopus 로고    scopus 로고
    • Optical test strip for trace Hg(II) based on doped sol-gel film
    • 10.1016/j.saa.2008.07.019
    • NA Yusof WARWA Kadir 2009 Optical test strip for trace Hg(II) based on doped sol-gel film Spectrochim Acta Part A 72 32 35 10.1016/j.saa.2008.07.019
    • (2009) Spectrochim Acta Part A , vol.72 , pp. 32-35
    • Yusof, N.A.1    Warwa, K.2
  • 16
    • 14844366596 scopus 로고    scopus 로고
    • 2O) for selective subnanomolar detection of Hg(II) ions
    • DOI 10.1016/j.aca.2004.10.069, PII S0003267004014230
    • M Shamsipur M Hosseini K Alizadeh N Alizadeh A Yari C Caltagirone V Lippolis 2005 Novel fluorimetric bulk optode membrane based on a dansylamidopropyl pendant arm derivative of 1-aza-4, 10-dithia-7- oxacyclododecane ([12]aneNS2O) for selective subnanomolar detection of Hg(II) ions Anal Chim Acta 533 1 17 24 10.1016/j.aca.2004.10.069 1:CAS:528: DC%2BD2MXit1Ogu7g%3D (Pubitemid 40357689)
    • (2005) Analytica Chimica Acta , vol.533 , Issue.1 , pp. 17-24
    • Shamsipur, M.1    Hosseini, M.2    Alizadeh, K.3    Alizadeh, N.4    Yari, A.5    Caltagirone, C.6    Lippolis, V.7
  • 17
    • 33745713707 scopus 로고    scopus 로고
    • Irreversible optical sensor for mercury determination based on tetraarylborate decompositon
    • 10.1016/j.snb.2005.11.009
    • C Cano-Raya MD Fernandez-Ramos J Gomez-Sanchez LF Capitan-Vallvey 2006 Irreversible optical sensor for mercury determination based on tetraarylborate decompositon Sens Actuators B 117 135 142 10.1016/j.snb.2005.11.009
    • (2006) Sens Actuators B , vol.117 , pp. 135-142
    • Cano-Raya, C.1    Fernandez-Ramos, M.D.2    Gomez-Sanchez, J.3    Capitan-Vallvey, L.F.4
  • 18
    • 71649099743 scopus 로고    scopus 로고
    • A sensitive and selective bulk optode for determination of Hg(II) based on hexathiacyclooctadecane and chromoionophore v
    • doi: 10.1016/j.snb.2008.12.029
    • Ensafi AA, Fouladgar M (2009) A sensitive and selective bulk optode for determination of Hg(II) based on hexathiacyclooctadecane and chromoionophore V. Sens Actuators B: Chemical. doi: 10.1016/j.snb.2008.12.029
    • (2009) Sens Actuators B: Chemical
    • Ensafi, A.A.1    Fouladgar, M.2
  • 19
    • 46449095435 scopus 로고    scopus 로고
    • Highly selective optical sensor for mercury assay based on covalent immobilization of 4-hydroxy salophen on a triacetylcellulose membrane
    • 10.1016/j.snb.2008.02.005
    • AA Ensafi AK Far S Meghdadi 2008 Highly selective optical sensor for mercury assay based on covalent immobilization of 4-hydroxy salophen on a triacetylcellulose membrane Sens Actuators B 133 84 90 10.1016/j.snb.2008.02.005
    • (2008) Sens Actuators B , vol.133 , pp. 84-90
    • Ensafi, A.A.1    Far, A.K.2    Meghdadi, S.3
  • 20
    • 33947117362 scopus 로고    scopus 로고
    • Fiber optic pH sensing with long wavelength excitable Schiff bases in the pH range of 7.0-12.0
    • DOI 10.1016/j.aca.2007.01.070, PII S0003267007002620
    • S Derinkuyu K Ertekin O Oter S Denizalti E Cetinkaya 2007 Fiber optic pH sensing with long wavelength excitable schiff bases in the pH range of 7.0-12.0 Anal Chim Acta 588 42 49 10.1016/j.aca.2007.01.070 1:CAS:528: DC%2BD2sXjtVartrY%3D 17386792 (Pubitemid 46399631)
    • (2007) Analytica Chimica Acta , vol.588 , Issue.1 , pp. 42-49
    • Derinkuyu, S.1    Ertekin, K.2    Oter, O.3    Denizalti, S.4    Cetinkaya, E.5
  • 21
    • 33846553668 scopus 로고    scopus 로고
    • Spectral characterization of a newly synthesized fluorescent semicarbazone derivative and its usage as a selective fiber optic sensor for copper(II)
    • DOI 10.1016/j.aca.2006.11.052, PII S0003267006022227
    • O Oter K Ertekin C Kirilmis M Koca 2007 Spectral characterization of a newly synthesized fluorescent semicarbazone derivative and its usage as a selective fiber optic sensor for copper (II) Anal Chim Acta 584 308 314 10.1016/j.aca.2006.11.052 1:CAS:528:DC%2BD2sXhtlSqtL0%3D 17386620 (Pubitemid 46161305)
    • (2007) Analytica Chimica Acta , vol.584 , Issue.2 , pp. 308-314
    • Oter, O.1    Ertekin, K.2    Kirilmis, C.3    Koca, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.