메뉴 건너뛰기




Volumn 94, Issue 4, 2010, Pages 440-444

Measurement of corneal aberrations for customisation of intraocular lens asphericity: Impact on quality of vision after micro-incision cataract surgery

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ASTIGMATISM; CATARACT EXTRACTION; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CLINICAL TRIAL; COMPARATIVE STUDY; CONTRAST SENSITIVITY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORNEA DISEASE; EYE REFRACTION; FEMALE; HUMAN; LENS IMPLANT; MALE; MEASUREMENT; MICROINCISION CATARACT SURGERY; OCULAR WAVEFRONT ABERRATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; VISUAL ACUITY; VISUAL SYSTEM PARAMETERS;

EID: 77950800648     PISSN: 00071161     EISSN: 14682079     Source Type: Journal    
DOI: 10.1136/bjo.2009.167775     Document Type: Article
Times cited : (30)

References (23)
  • 2
    • 0031986381 scopus 로고    scopus 로고
    • Presbyopia and the optical changes in the human crystalline lens with age
    • DOI 10.1016/S0042-6989(97)00102-8, PII S0042698997001028
    • Glasser A, Campbell MC. Presbyopia and the optical changes in the human crystalline lens with age. Vision Res 1998;38:209-229 (Pubitemid 27503836)
    • (1998) Vision Research , vol.38 , Issue.2 , pp. 209-229
    • Glasser, A.1    Campbell, M.C.W.2
  • 4
    • 0036357722 scopus 로고    scopus 로고
    • Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
    • Artal P, Berrio E, Guirao A, et al. Contribution of the cornea and internal surfaces to the change of ocular aberrations with age. J Opt Soc Am A Opt Image Sci Vis 2002;19:137-143
    • (2002) J Opt Soc Am a Opt Image Sci Vis , vol.19 , pp. 137-143
    • Artal, P.1    Berrio, E.2    Guirao, A.3
  • 5
  • 6
    • 57649218728 scopus 로고    scopus 로고
    • Analysis of the possible benefits of aspheric intraocular lenses: Review of the literature
    • Montes-Mico R, Ferrer-Blasco T, Cervino A. Analysis of the possible benefits of aspheric intraocular lenses: review of the literature. J Cataract Refract Surg 2009;35:172-181
    • (2009) J Cataract Refract Surg , vol.35 , pp. 172-181
    • Montes-Mico, R.1    Ferrer-Blasco, T.2    Cervino, A.3
  • 7
    • 33845617907 scopus 로고    scopus 로고
    • Optimizing higher-order aberrations with intraocular lens technology
    • DOI 10.1097/ICU.0b013e3280121af1, PII 0005573520070200000015
    • Belluci R, Morselli S. Optimizing higher-order aberrations with intraocular lens technology. Curr Opin Ophthalmol 2007;18:67-73. (Pubitemid 44949830)
    • (2007) Current Opinion in Ophthalmology , vol.18 , Issue.1 , pp. 67-73
    • Bellucci, R.1    Morselli, S.2
  • 9
    • 59449085428 scopus 로고    scopus 로고
    • Aspheric intraocular lens selection based on corneal wavefront
    • Packer M, Fine IH, Hoffman RS. Aspheric intraocular lens selection based on corneal wavefront. J Refract Surg 2009;25:12-20.
    • (2009) J Refract Surg , vol.25 , pp. 12-20
    • Packer, M.1    Fine, I.H.2    Hoffman, R.S.3
  • 10
    • 57149118077 scopus 로고    scopus 로고
    • Intraindividual comparative study of corneal and ocular wavefront aberrations after biaxial microincision versus coaxial small-incision cataract surgery
    • Denoyer A, Denoyer L, Marotte D, et al. Intraindividual comparative study of corneal and ocular wavefront aberrations after biaxial microincision versus coaxial small-incision cataract surgery. Br J Ophthalmol 2008;92:1679-1684
    • (2008) Br J Ophthalmol , vol.92 , pp. 1679-1684
    • Denoyer, A.1    Denoyer, L.2    Marotte, D.3
  • 11
    • 34447621950 scopus 로고    scopus 로고
    • Personalized correction of spherical aberration in cataract surgery
    • Beiko GHH. Personalized correction of spherical aberration in cataract surgery. J Cataract Refract Surg 2007;33:1455-1460
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1455-1460
    • Beiko, G.H.H.1
  • 14
    • 0025096497 scopus 로고
    • Rapid determination of intraocular lens tilt and decentration through the undilated pupil
    • Guyton DL, Uotazo H, Wisnicki HJ. Rapid determination of intraocular lens tilt and decentration through the undilated pupil. Ophthalmology 1990;97:1259-1264
    • (1990) Ophthalmology , vol.97 , pp. 1259-1264
    • Guyton, D.L.1    Uotazo, H.2    Wisnicki, H.J.3
  • 15
    • 14244264014 scopus 로고    scopus 로고
    • Ocular higher-order aberrations in eyes with supernormal vision
    • DOI 10.1016/j.ajo.2004.08.035
    • Levy Y, Segal O, Avni I, et al. Ocular higher-order aberrations in eyes with supernormal vision. Am J Ophthalmol 2005;139:225-228 (Pubitemid 40288264)
    • (2005) American Journal of Ophthalmology , vol.139 , Issue.2 , pp. 225-228
    • Levy, Y.1    Segal, O.2    Avni, I.3    Zadok, D.4
  • 16
    • 34447130253 scopus 로고    scopus 로고
    • A comparison of higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses
    • Awwad ST, Lehmann JD, McCulley JP, et al. A comparison of higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses. Eur J Ophthalmol 2007;17:320-326
    • (2007) Eur J Ophthalmol , vol.17 , pp. 320-326
    • Awwad, S.T.1    Lehmann, J.D.2    McCulley, J.P.3
  • 17
    • 33750084170 scopus 로고    scopus 로고
    • Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: A randomized prospective study
    • Rocha KM, Soriano ES, Chalita MR, et al. Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study. Am J Ophthalmol 2006;142:750-756
    • (2006) Am J Ophthalmol , vol.142 , pp. 750-756
    • Rocha, K.M.1    Soriano, E.S.2    Chalita, M.R.3
  • 18
    • 3242772864 scopus 로고    scopus 로고
    • Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses
    • Bellucci R, Morselli S, Piers P. Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses. J Refract Surg 2004;20:297-306. (Pubitemid 38971020)
    • (2004) Journal of Refractive Surgery , vol.20 , Issue.4 , pp. 297-306
    • Bellucci, R.1    Morselli, S.2    Piers, P.3
  • 19
    • 34548713585 scopus 로고    scopus 로고
    • Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes
    • Caporossi A, Martone G, Casprini F, et al. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J Refract Surg 2007;23:639-648 (Pubitemid 47424669)
    • (2007) Journal of Refractive Surgery , vol.23 , Issue.7 , pp. 639-648
    • Caporossi, A.1    Martone, G.2    Casprini, F.3    Rapisarda, L.4
  • 20
    • 57749208541 scopus 로고    scopus 로고
    • Customizing the correction of spherical aberration
    • Beiko G. Customizing the correction of spherical aberration. Cataract Refract Surg Today 2006;6:92-94
    • (2006) Cataract Refract Surg Today , vol.6 , pp. 92-94
    • Beiko, G.1
  • 21
    • 57649149624 scopus 로고    scopus 로고
    • Aspheric IOLs - Matching corneal and IOL wavefront
    • Chang DF, ed Thorofare, NJ: Slack
    • Beiko GHH. Aspheric IOLs - matching corneal and IOL wavefront. In: Chang DF, ed Mastering Refractive IOLs; the Art and Science. Thorofare, NJ: Slack, 2008;278-281
    • (2008) Mastering Refractive IOLs; the Art and Science , pp. 278-281
    • Beiko, G.H.H.1
  • 23
    • 67349276407 scopus 로고    scopus 로고
    • Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration
    • Pepose JS, Qazi MA, Edwards KH, et al. Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration. Graefes Arch Clin Exp Ophthalmol 2009;247:965-973
    • (2009) Graefes Arch Clin Exp Ophthalmol , vol.247 , pp. 965-973
    • Pepose, J.S.1    Qazi, M.A.2    Edwards, K.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.