메뉴 건너뛰기




Volumn 31, Issue 4, 2010, Pages 615-619

In vitro evaluation of MR imaging issues at 3T for aneurysm clips made from MP35N: Findings and information applied to 155 additional aneurysm clips

Author keywords

[No Author keywords available]

Indexed keywords

SODIUM CHLORIDE;

EID: 77950786741     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A1918     Document Type: Article
Times cited : (41)

References (33)
  • 2
    • 59149093137 scopus 로고    scopus 로고
    • Treatment of unruptured intracranial aneurysms: Surgery, coiling, or nothing?
    • Burns JD, Brown RD Jr. Treatment of unruptured intracranial aneurysms: surgery, coiling, or nothing? Curr Neurol Neurosci Rep 2009;9:6-12
    • (2009) Curr Neurol Neurosci Rep , vol.9 , pp. 6-12
    • Burns, J.D.1    Brown Jr., R.D.2
  • 3
    • 0027173880 scopus 로고
    • Placement of a ferromagnetic intracerebral aneurysm clip in a magnetic field with a fatal outcome
    • Klucznik RP, Carrier DA, Pyka R, et al. Placement of a ferromagnetic intracerebral aneurysm clip in a magnetic field with a fatal outcome. Radiology 1993; 187:855-856 (Pubitemid 23155727)
    • (1993) Radiology , vol.187 , Issue.3 , pp. 855-856
    • Klucznik, R.P.1    Carrier, D.A.2    Pyka, R.3    Haid, R.W.4
  • 4
    • 0027288363 scopus 로고
    • Need for caution during MR imaging of patients with aneurysm clips [2]
    • Johnson GC. Need for caution duringMRimaging of patients with aneurysm clips. Radiology 1993;188:287-288 (Pubitemid 23183142)
    • (1993) Radiology , vol.188 , Issue.1 , pp. 287-288
    • Johnson, G.C.1
  • 5
    • 0027193340 scopus 로고
    • MR imaging of patients with intracranial aneurysm clips
    • Kanal E, Shellock FG. MR imaging of patients with intracranial aneurysm clips. Radiology 1993;187:612-614 (Pubitemid 23155681)
    • (1993) Radiology , vol.187 , Issue.3 , pp. 612-614
    • Kanal, E.1    Shellock, F.G.2
  • 6
    • 0025718057 scopus 로고
    • Policies, guidelines, and recommendations for MR imaging safety and patient management
    • Shellock FG, Kanal E. Policies, guidelines, and recommendations for MR imaging safety and patient management. J Magn Reson Imaging 1991;1:97-101
    • (1991) J Magn Reson Imaging , vol.1 , pp. 97-101
    • Shellock, F.G.1    Kanal, E.2
  • 7
    • 53249100687 scopus 로고    scopus 로고
    • MRI safety update 2008. Part 2. Screening patients for MRI
    • Shellock FG, Spinazzi A.MRIsafety update 2008. Part 2. Screening patients for MRI. AJR Am J Roentgenol 2008;191:1140-1149
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 1140-1149
    • Shellock, F.G.1    Spinazzi, A.2
  • 9
    • 0020614309 scopus 로고
    • Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging
    • New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148
    • (1983) Radiology , vol.147 , pp. 139-148
    • New, P.F.J.1    Rosen, B.R.2    Brady, T.J.3
  • 11
    • 0030012490 scopus 로고    scopus 로고
    • Aneurysm clip testing for ferromagnetic properties: Clip variability issues
    • Kanal E, Shellock FG, Lewin JS. Aneurysm clip testing for ferromagnetic properties: clip variability issues. Radiology 1996;200:576-578 (Pubitemid 26249920)
    • (1996) Radiology , vol.200 , Issue.2 , pp. 576-578
    • Kanal, E.1    Shellock, F.G.2    Lewin, J.S.3
  • 12
    • 0023814837 scopus 로고
    • High-field strength MR imaging and metallic biomedical implants: An ex vivo evaluation of deflection forces
    • Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. AJR Am J Roentgenol 1988;151:389-392
    • (1988) AJR Am J Roentgenol , vol.151 , pp. 389-392
    • Shellock, F.G.1    Crues, J.V.2
  • 13
    • 0031884231 scopus 로고    scopus 로고
    • Spetzler aneurysm clips: Compatibility at MR imaging
    • Shellock FG, Shellock VJ. Spetzler aneurysm clips: compatibility at MR imaging. Radiology 1998;206:838-41
    • (1998) Radiology , vol.206 , pp. 838-841
    • Shellock, F.G.1    Shellock, V.J.2
  • 14
    • 0031812967 scopus 로고    scopus 로고
    • Yasargil aneurysm clips: Evaluation of interactions with a 1.5 Tesla MR system
    • Shellock FG, Kanal E. Yasargil aneurysm clips: evaluation of interactions with a 1.5 Tesla MR system. Radiology 1998;207:587-91
    • (1998) Radiology , vol.207 , pp. 587-591
    • Shellock, F.G.1    Kanal, E.2
  • 15
    • 0033932711 scopus 로고    scopus 로고
    • Safety of MR scanning in patients with nonferromagnetic aneurysm clips
    • Pride GL, Kowal J, Mendelsohn DB, et al. Safety of MR scanning in patients with nonferromagnetic aneurysm clips. J Magn Reson Imaging 2000;12:198-200
    • (2000) J Magn Reson Imaging , vol.12 , pp. 198-200
    • Pride, G.L.1    Kowal, J.2    Mendelsohn, D.B.3
  • 16
    • 0037347512 scopus 로고    scopus 로고
    • Aneurysm clips: Evaluation of magnetic field interactions and translational attraction using "long-bore" and "short-bore" 3.0-Tesla MR systems
    • Shellock FG, Tkach JA, Ruggieri PM, et al. Aneurysm clips: evaluation of magnetic field interactions and translational attraction using "long-bore" and "short-bore" 3.0-Tesla MR systems. AJNR Am J Neuroradiol 2003;24:463-71
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 463-471
    • Shellock, F.G.1    Tkach, J.A.2    Ruggieri, P.M.3
  • 17
    • 0036891641 scopus 로고    scopus 로고
    • Biomedical implants and devices: Assessment of magnetic field interactions with a 3.0-TeslaMRsystem
    • Shellock FG. Biomedical implants and devices: assessment of magnetic field interactions with a 3.0-TeslaMRsystem. J MagnReson Imaging 2002;16:721-32
    • (2002) J MagnReson Imaging , vol.16 , pp. 721-732
    • Shellock, F.G.1
  • 18
    • 42449110749 scopus 로고    scopus 로고
    • Whole-body high-field-strength (3.0-T)MR imaging in clinical practice. Part II. Technical considerations and clinical applications
    • Kuhl CK, Träber F, Gieseke J, et al. Whole-body high-field-strength (3.0-T)MR imaging in clinical practice. Part II. Technical considerations and clinical applications. Radiology 2008;247:16-35
    • (2008) Radiology , vol.247 , pp. 16-35
    • Kuhl, C.K.1    Träber, F.2    Gieseke, J.3
  • 19
    • 35848942605 scopus 로고    scopus 로고
    • Standards for medical devices in MRI: Present and future
    • Woods TO. Standards for medical devices in MRI: present and future. J Magn Reson Imaging 2007;26:1186-89
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1186-1189
    • Woods, T.O.1
  • 20
    • 29244468417 scopus 로고    scopus 로고
    • Detachable coil for cerebral aneurysms: In vitro evaluation of magnet field interactions, heating, and artifacts at 3-Tesla
    • Shellock FG, Gounis M, Wakhloo A. Detachable coil for cerebral aneurysms: in vitro evaluation of magnet field interactions, heating, and artifacts at 3-Tesla. AJNR Am J Neuroradiol 2005;26:363-66
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 363-366
    • Shellock, F.G.1    Gounis, M.2    Wakhloo, A.3
  • 21
    • 34547734900 scopus 로고    scopus 로고
    • Magnetically programmable shunt valve: MRI at 3-Tesla
    • Epub 2007 Jan 19
    • Shellock FG, Wilson SF, Mauge CP. Magnetically programmable shunt valve: MRI at 3-Tesla. Magn Reson Imaging 2007;25:1116 -21. Epub 2007 Jan 19
    • (2007) Magn Reson Imaging , vol.25 , pp. 1116-1121
    • Shellock, F.G.1    Wilson, S.F.2    Mauge, C.P.3
  • 22
    • 47049118674 scopus 로고    scopus 로고
    • Ventricular assist implant (AB5000): In vitro assessment of MRI issues at 3-Tesla
    • Shellock FG, Valencerina S. Ventricular assist implant (AB5000): in vitro assessment of MRI issues at 3-Tesla. J Cardiovasc Magn Resonance 2008;10:23-28
    • (2008) J Cardiovasc Magn Resonance , vol.10 , pp. 23-28
    • Shellock, F.G.1    Valencerina, S.2
  • 23
    • 23644434337 scopus 로고    scopus 로고
    • Standard test method for measurement of magnetically induced displacement force on passive implants in the magnetic resonance environment
    • American Society for Testing and Materials (ASTM. Designation: F 2052-02). Vol 13.01. West Conshohocken, Pennsylvania: Medical Devices: Emergency Medical Services
    • American Society for Testing and Materials (ASTM. Designation: F 2052-02). Standard test method for measurement of magnetically induced displacement force on passive implants in the magnetic resonance environment. In: Annual Book of ASTM Standards: Section 13 - Medical Devices and Services. Vol 13.01. West Conshohocken, Pennsylvania: Medical Devices: Emergency Medical Services; 1576-1580
    • Annual Book of ASTM Standards: Section 13 - Medical Devices and Services , pp. 1576-1580
  • 24
    • 4344615994 scopus 로고    scopus 로고
    • Standard test method for measurement of radio frequency induced heating near passive implants during magnetic resonance imaging
    • American Society for Testing and Materials International (ASTM. Designation F 2182-02a). West Conshohocken, Pennsylvania: ASTM International
    • American Society for Testing and Materials International (ASTM. Designation F 2182-02a). Standard test method for measurement of radio frequency induced heating near passive implants during magnetic resonance imaging. In: Annual Book of ASTM Standards. West Conshohocken, Pennsylvania: ASTM International
    • Annual Book of ASTM Standards
  • 25
    • 27744528624 scopus 로고    scopus 로고
    • Power deposition inside of a phantom for testing MRI heating
    • Amjad A, Kildishev AV, Park SM, et al. Power deposition inside of a phantom for testing MRI heating. IEEE Trans Magn 2005;41:4185-87
    • (2005) IEEE Trans Magn , vol.41 , pp. 4185-4187
    • Amjad, A.1    Kildishev, A.V.2    Park, S.M.3
  • 26
    • 49049091927 scopus 로고    scopus 로고
    • Spatial distribution of RF-induced E-fields and implant heating in MRI
    • Nordbeck P, Fidler F, Weiss I, et al. Spatial distribution of RF-induced E-fields and implant heating in MRI. Magn Reson Med. 2008;60:312-91
    • (2008) Magn Reson Med , vol.60 , pp. 312-391
    • Nordbeck, P.1    Fidler, F.2    Weiss, I.3
  • 28
    • 0031757334 scopus 로고    scopus 로고
    • Aneurysm clips: Evaluation of MR imaging artifacts at 1.5-T
    • Shellock FG, Kanal E. Aneurysm clips: evaluation of MR imaging artifacts at 1.5-T. Radiology 1998;209:563-66
    • (1998) Radiology , vol.209 , pp. 563-566
    • Shellock, F.G.1    Kanal, E.2
  • 29
    • 24744444958 scopus 로고    scopus 로고
    • Magnetic resonance imaging artifacts caused by aneurysm clips and shunt valves: Dependence on field strength (1.5 and 3-T) and imaging parameters
    • Olsrud J, Latt J, Brockstedt S, et al. Magnetic resonance imaging artifacts caused by aneurysm clips and shunt valves: dependence on field strength (1.5 and 3-T) and imaging parameters. J Magn Reson Imaging 2005;22:433-37
    • (2005) J Magn Reson Imaging , vol.22 , pp. 433-437
    • Olsrud, J.1    Latt, J.2    Brockstedt, S.3
  • 31
    • 0035085031 scopus 로고    scopus 로고
    • Investigation of the factors responsible for burns during MRI
    • Dempsey MF, Condon B, Hadley DM. Investigation of the factors responsible for burns during MRI. J Magn Reson Imaging 2001;13:627-31
    • (2001) J Magn Reson Imaging , vol.13 , pp. 627-631
    • Dempsey, M.F.1    Condon, B.2    Hadley, D.M.3
  • 32
    • 77950831140 scopus 로고    scopus 로고
    • Standard practice for marking medical devices and other items for safety in the magnetic resonance environment
    • American Society for Testing and Materials (ASTM. Designation: F2503-05). West Conshohocken, Pennsylvania: ASTM International
    • American Society for Testing and Materials (ASTM. Designation: F2503-05). Standard practice for marking medical devices and other items for safety in the magnetic resonance environment. In: Annual Book of ASTM Standards. West Conshohocken, Pennsylvania: ASTM International; 2005
    • (2005) Annual Book of ASTM Standards
  • 33
    • 70350513070 scopus 로고    scopus 로고
    • MRI labeling information for implants and devices: Explanation of terminology
    • Shellock FG, Woods TO, Crues JV 3rd. MRI labeling information for implants and devices: explanation of terminology. Radiology 2009;253:26-30
    • (2009) Radiology , vol.253 , pp. 26-30
    • Shellock, F.G.1    Woods, T.O.2    Crues III, J.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.