메뉴 건너뛰기




Volumn 26, Issue 2, 2005, Pages 363-366

Detachable coil for cerebral aneurysms: In vitro evaluation of magnetic field interactions, heating, and artifacts at 3T

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ARTIFACT; BRAIN ARTERY ANEURYSM; DEVICE; DIAGNOSTIC IMAGING; EQUIPMENT DESIGN; HEATING; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMPLANT; MAGNETIC FIELD; NUCLEAR MAGNETIC RESONANCE IMAGING; SAFETY; SIGNAL DETECTION;

EID: 29244468417     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (41)

References (17)
  • 1
    • 0037180253 scopus 로고    scopus 로고
    • International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomized trial
    • Molyneux A, Kerr R, Stratton I, Sandercock P, Clarke M, Shrimpton J, Holman R, International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. Lancet 2002;360:1267-1274
    • (2002) Lancet , vol.360 , pp. 1267-1274
    • Molyneux, A.1    Kerr, R.2    Stratton, I.3    Sandercock, P.4    Clarke, M.5    Shrimpton, J.6    Holman, R.7
  • 2
    • 1842296356 scopus 로고    scopus 로고
    • Guglielmi detachable coil embolization of acuteintracranial ancurysni: Perioperative anatomical and clinical outcome in 403 patients
    • Vinuela F, Duckwiler G, Mawad M. Guglielmi detachable coil embolization of acuteintracranial ancurysni: perioperative anatomical and clinical outcome in 403 patients. J Neurosurg 1997;86:475-482
    • (1997) J Neurosurg , vol.86 , pp. 475-482
    • Vinuela, F.1    Duckwiler, G.2    Mawad, M.3
  • 3
    • 0031034081 scopus 로고    scopus 로고
    • Saccular intracranial aneurysms: Endovascular treatment with mechanical detachable spiral coils
    • Tournade A, Courtheoux P, Sengel C, Ozgulle S, Tajahmady T. Saccular intracranial aneurysms: endovascular treatment with mechanical detachable spiral coils. Radiology 1997;202:481-486
    • (1997) Radiology , vol.202 , pp. 481-486
    • Tournade, A.1    Courtheoux, P.2    Sengel, C.3    Ozgulle, S.4    Tajahmady, T.5
  • 4
    • 1242316379 scopus 로고    scopus 로고
    • Endovascular treatment of intracranial wide-necked aneurysms using three-dimensional coils: Predictors of immediate anatomic and clinical results
    • Vallee J-N, Pierot L, Bonafe A, Turjman F, Flandroy P, Berge J, Rodesch G, Bracard S. Endovascular treatment of intracranial wide-necked aneurysms using three-dimensional coils: predictors of immediate anatomic and clinical results. AJNR Am J Neuroradiol 2004;25:298-306
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 298-306
    • Vallee, J.-N.1    Pierot, L.2    Bonafe, A.3    Turjman, F.4    Flandroy, P.5    Berge, J.6    Rodesch, G.7    Bracard, S.8
  • 5
    • 0344631109 scopus 로고    scopus 로고
    • MR angiography with three-dimensional time-of-flight and targeted maximum-intensity-projection reconstructions in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils
    • Kahara VJ, Seppanen SK, Ryymin PS, Mattila P, Laasonen EM. MR angiography with three-dimensional time-of-flight and targeted maximum-intensity-projection reconstructions in the follow-up of intracranial aneurysms embolized with Guglielmi detachable coils. AJNR Am J Neuroradiol 1999;20:1470-1475
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 1470-1475
    • Kahara, V.J.1    Seppanen, S.K.2    Ryymin, P.S.3    Mattila, P.4    Laasonen, E.M.5
  • 7
    • 0035008720 scopus 로고    scopus 로고
    • In vitro evaluation of platinum Guglielmi detachable coils at 3 T with a porcine model: Safety issues and artifacts
    • Hennemeyer CT, Wicklow K, Feinberg DA, Derdeyn CP. In vitro evaluation of platinum Guglielmi detachable coils at 3 T with a porcine model: Safety issues and artifacts. Radiology 2001;219:732-737
    • (2001) Radiology , vol.219 , pp. 732-737
    • Hennemeyer, C.T.1    Wicklow, K.2    Feinberg, D.A.3    Derdeyn, C.P.4
  • 9
    • 0036891641 scopus 로고    scopus 로고
    • Biomedical implants and devices: Assessment of magnetic field interactions with a 3.0-Tesla MR system
    • Shellock FG. Biomedical implants and devices: assessment of magnetic field interactions with a 3.0-Tesla MR system. J Magn Reson Imaging 2002;16:721-732
    • (2002) J Magn Reson Imaging , vol.16 , pp. 721-732
    • Shellock, F.G.1
  • 10
    • 23644434337 scopus 로고    scopus 로고
    • Standard test method for measurement of magnetically induced displacement force on passive implants in the magnetic resonance environment
    • West Conshohocken, PA
    • American Society for Testing and Materials (ASTM) International: F2052. Standard test method for measurement of magnetically induced displacement force on passive implants in the magnetic resonance environment. In: Annual Book of ASTM Standards, Volume 13.01 Medical Devices; West Conshohocken, PA, 2001;pp: 1576-1580
    • (2001) Annual Book of ASTM Standards, Volume 13.01 Medical Devices , pp. 1576-1580
  • 11
    • 30444449308 scopus 로고    scopus 로고
    • F2182 Test method for measurement of radio frequency induced heating near passive implants during magnetic resonance imaging
    • West Conshohocken, PA
    • American Society for Testing and Materials (ASTM) International. F2182 Test method for measurement of radio frequency induced heating near passive implants during magnetic resonance imaging. American Society for Testing and Materials (ASTM) International, West Conshohocken, PA2003
    • (2003) American Society for Testing and Materials (ASTM) International
  • 13
    • 0031757334 scopus 로고    scopus 로고
    • Aneurysm clips: Evaluation of MR imaging artifacts at 1.5 Tesla
    • Shellock FG, Kanal E. Aneurysm clips: Evaluation of MR imaging artifacts at 1.5 Tesla. Radiology 1998;209:563-566
    • (1998) Radiology , vol.209 , pp. 563-566
    • Shellock, F.G.1    Kanal, E.2
  • 14
    • 1542373371 scopus 로고    scopus 로고
    • F2119 Test method for evaluation of MR image artifacts from passive implants
    • West Conshohocken, PA
    • American Society for Testing and Materials (ASTM) International: F2119 Test method for evaluation of MR image artifacts from passive implants. American Society for Testing and Materials (ASTM) International, West Conshohocken, PA2003
    • (2003) American Society for Testing and Materials (ASTM) International
  • 16
    • 0031771124 scopus 로고    scopus 로고
    • Minimizing artifacts caused by metallic implants at MR imaging: Experimental and clinical studies
    • Suh JS, Jeong EK, Shin KY, et al. Minimizing artifacts caused by metallic implants at MR imaging: experimental and clinical studies. AJR Am J Roentgenot 1998;171:1207-1213.
    • (1998) AJR Am J Roentgenot , vol.171 , pp. 1207-1213
    • Suh, J.S.1    Jeong, E.K.2    Shin, K.Y.3
  • 17
    • 0036105905 scopus 로고    scopus 로고
    • Commentary: MR safety and the American College of Radiology White Paper
    • Shellock FG, Crues JV. Commentary: MR safety and the American College of Radiology White Paper. AJR Am J Roentgenology 2002; 178:1349-1352
    • (2002) AJR Am J Roentgenology , vol.178 , pp. 1349-1352
    • Shellock, F.G.1    Crues, J.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.