메뉴 건너뛰기




Volumn 43, Issue 6, 2010, Pages 1138-1145

Pullout strength of suture anchors: Effect of mechanical properties of trabecular bone

Author keywords

Micro CT; Microstructure; Pullout strength; Suture anchors; Synthetic bone

Indexed keywords

BIOMECHANICAL TESTS; BONE VOLUME FRACTION; MICRO-CT; MICROCOMPUTED TOMOGRAPHY; MICROSTRUCTURAL PROPERTIES; MICROSTRUCTURE-PROPERTY RELATIONSHIPS; PULL-OUT STRENGTH; SAWBONE; SIMILARITIES AND DIFFERENCES; SPECIFIC LOCATION; STRUCTURAL MODEL INDICES; SUTURE ANCHOR; SYNTHETIC BONE; TRABECULAR BONES; TRABECULAR THICKNESS;

EID: 77950692204     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.12.007     Document Type: Article
Times cited : (55)

References (31)
  • 2
    • 0030919473 scopus 로고    scopus 로고
    • The relationship of suture anchor failure and bone density to proximal humerus location: a cadaveric study
    • Barber F.A., Feder S.M., et al. The relationship of suture anchor failure and bone density to proximal humerus location: a cadaveric study. Arthroscopy: The Journal of Arthroscopic & Related Surgery 1997, 13(3):340-345.
    • (1997) Arthroscopy: The Journal of Arthroscopic & Related Surgery , vol.13 , Issue.3 , pp. 340-345
    • Barber, F.A.1    Feder, S.M.2
  • 6
    • 0030221045 scopus 로고    scopus 로고
    • Factors affecting the pullout strength of cancellous bone screws
    • Chapman J.R., Harrington R.M., et al. Factors affecting the pullout strength of cancellous bone screws. Journal of Biomechanical Engineering 1996, 118(3):391-398.
    • (1996) Journal of Biomechanical Engineering , vol.118 , Issue.3 , pp. 391-398
    • Chapman, J.R.1    Harrington, R.M.2
  • 8
    • 0026229643 scopus 로고
    • Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography
    • Ciarelli M.J., Goldstein S.A., et al. Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography. Journal of Orthopaedic Research 1991, 9(5):674-682.
    • (1991) Journal of Orthopaedic Research , vol.9 , Issue.5 , pp. 674-682
    • Ciarelli, M.J.1    Goldstein, S.A.2
  • 10
    • 1642602616 scopus 로고    scopus 로고
    • Changed morphology and mechanical properties of cancellous bone in the mandibular condyles of edentate people
    • Giesen E.B., Ding M., et al. Changed morphology and mechanical properties of cancellous bone in the mandibular condyles of edentate people. Journal of Dental Research 2004, 83(3):255-259.
    • (2004) Journal of Dental Research , vol.83 , Issue.3 , pp. 255-259
    • Giesen, E.B.1    Ding, M.2
  • 11
    • 0027168989 scopus 로고
    • Measurement and significance of three-dimensional architecture to the mechanical integrity of trabecular bone
    • Goldstein S.A., Goulet R., et al. Measurement and significance of three-dimensional architecture to the mechanical integrity of trabecular bone. Calcified Tissue International 1993, 53(Suppl 1):S127.
    • (1993) Calcified Tissue International , vol.53 , Issue.SUPPL. 1
    • Goldstein, S.A.1    Goulet, R.2
  • 12
    • 0028416797 scopus 로고
    • The relationship between the structural and orthogonal compressive properties of trabecular bone
    • Goulet R.W., Goldstein S.A., et al. The relationship between the structural and orthogonal compressive properties of trabecular bone. Journal of Biomechanics 1994, 27(4):375-389.
    • (1994) Journal of Biomechanics , vol.27 , Issue.4 , pp. 375-389
    • Goulet, R.W.1    Goldstein, S.A.2
  • 13
    • 61549123434 scopus 로고    scopus 로고
    • Sawbones in Biomechanical Settings-a Review
    • Hausmann J.T. Sawbones in Biomechanical Settings-a Review. Osteo Trauma Care 2006, 14:259-264.
    • (2006) Osteo Trauma Care , vol.14 , pp. 259-264
    • Hausmann, J.T.1
  • 14
    • 0024893262 scopus 로고
    • X-ray quantitative computed tomography: the relations to physical properties of proximal tibial trabecular bone specimens
    • Hvid I., Bentzen S.M., et al. X-ray quantitative computed tomography: the relations to physical properties of proximal tibial trabecular bone specimens. Journal of Biomechanics 1989, 22(8-9):837-844.
    • (1989) Journal of Biomechanics , vol.22 , Issue.8-9 , pp. 837-844
    • Hvid, I.1    Bentzen, S.M.2
  • 15
    • 57049144254 scopus 로고    scopus 로고
    • Predicting regional variations in trabecular bone mechanical properties within the human proximal tibia using MR imaging
    • Lancianese S.L., Kwok E., et al. Predicting regional variations in trabecular bone mechanical properties within the human proximal tibia using MR imaging. Bone 2008, 43(6):1039-1046.
    • (2008) Bone , vol.43 , Issue.6 , pp. 1039-1046
    • Lancianese, S.L.1    Kwok, E.2
  • 16
    • 33749257128 scopus 로고    scopus 로고
    • Quantification of the roles of trabecular microarchitecture and trabecular type in determining the elastic modulus of human trabecular bone
    • Liu X.S., Sajda P., et al. Quantification of the roles of trabecular microarchitecture and trabecular type in determining the elastic modulus of human trabecular bone. Journal of Bone and Mineral Research 2006, 21(10):1608-1617.
    • (2006) Journal of Bone and Mineral Research , vol.21 , Issue.10 , pp. 1608-1617
    • Liu, X.S.1    Sajda, P.2
  • 17
    • 28344452777 scopus 로고    scopus 로고
    • Suture anchors and tacks for shoulder surgery, part 1: biology and biomechanics
    • McFarland E.G., Park H.B., et al. Suture anchors and tacks for shoulder surgery, part 1: biology and biomechanics. The American Journal of Sports Medicine 2005, 33(12):1918-1923.
    • (2005) The American Journal of Sports Medicine , vol.33 , Issue.12 , pp. 1918-1923
    • McFarland, E.G.1    Park, H.B.2
  • 19
    • 33645080705 scopus 로고    scopus 로고
    • Ultrasonically implanted PLA suture anchors are stable in osteopenic bone
    • Meyer D.C., Mayer J., et al. Ultrasonically implanted PLA suture anchors are stable in osteopenic bone. Clinical Orthopaedics and Related Research 2006, 442:143-148.
    • (2006) Clinical Orthopaedics and Related Research , vol.442 , pp. 143-148
    • Meyer, D.C.1    Mayer, J.2
  • 20
    • 77950690633 scopus 로고    scopus 로고
    • Millenium Research Group. US Markets for Orthopedic Soft Tissue Solutions.
    • Millenium Research Group (2007). US Markets for Orthopedic Soft Tissue Solutions.
    • (2007)
  • 21
    • 40149105072 scopus 로고    scopus 로고
    • Evaluation of the mechanical and architectural properties of glenoid bone
    • Mimar R., Limb D., et al. Evaluation of the mechanical and architectural properties of glenoid bone. Journal of Shoulder and Elbow Surgery 2008, 17(2):336-341.
    • (2008) Journal of Shoulder and Elbow Surgery , vol.17 , Issue.2 , pp. 336-341
    • Mimar, R.1    Limb, D.2
  • 23
    • 29844436781 scopus 로고    scopus 로고
    • Suture anchors and tacks for shoulder surgery, part II: the prevention and treatment of complications
    • Park H.B., Keyurapan E., et al. Suture anchors and tacks for shoulder surgery, part II: the prevention and treatment of complications. The American Journal of Sports Medicine 2006, 34(1):136-144.
    • (2006) The American Journal of Sports Medicine , vol.34 , Issue.1 , pp. 136-144
    • Park, H.B.1    Keyurapan, E.2
  • 24
    • 60449094905 scopus 로고    scopus 로고
    • Suture anchor fixation strength in osteopenic versus non-osteopenic bone for rotator cuff repair
    • Pietschmann M.F., Fróhlich V., et al. Suture anchor fixation strength in osteopenic versus non-osteopenic bone for rotator cuff repair. Archives of Orthopaedic and Trauma Surgery 2009, 129(3):373-379.
    • (2009) Archives of Orthopaedic and Trauma Surgery , vol.129 , Issue.3 , pp. 373-379
    • Pietschmann, M.F.1    Fróhlich, V.2
  • 26
    • 0015667763 scopus 로고
    • Elastic and viscoelastic properties of trabecular bone: dependence on structure
    • Pugh J.W., Rose R.M., et al. Elastic and viscoelastic properties of trabecular bone: dependence on structure. Journal of Biomechanics 1973, 6(5):475-485.
    • (1973) Journal of Biomechanics , vol.6 , Issue.5 , pp. 475-485
    • Pugh, J.W.1    Rose, R.M.2
  • 27
    • 4143085936 scopus 로고    scopus 로고
    • Anchor design and bone mineral density affect the pull-out strength of suture anchors in rotator cuff repair: which anchors are best to use in patients with low bone quality?
    • Tingart M.J., Apreleva M., et al. Anchor design and bone mineral density affect the pull-out strength of suture anchors in rotator cuff repair: which anchors are best to use in patients with low bone quality?. The American Journal of Sports Medicine 2004, 32(6):1466-1473.
    • (2004) The American Journal of Sports Medicine , vol.32 , Issue.6 , pp. 1466-1473
    • Tingart, M.J.1    Apreleva, M.2
  • 29
    • 67749124110 scopus 로고    scopus 로고
    • Bearing area: a new indication for suture anchor pullout strength?
    • Yakacki C.M., Griffis J., et al. Bearing area: a new indication for suture anchor pullout strength?. Journal of Orthopaedic Research 2009, 27(8):1048-1054.
    • (2009) Journal of Orthopaedic Research , vol.27 , Issue.8 , pp. 1048-1054
    • Yakacki, C.M.1    Griffis, J.2
  • 30
    • 77950690265 scopus 로고    scopus 로고
    • The effect of trabecular microstructure on the pullout strength of suture anchors. Journal of Biomechanics, under review.
    • Yakacki, C.M., M. Poukalova, et al. The effect of trabecular microstructure on the pullout strength of suture anchors. Journal of Biomechanics, under review.
    • Yakacki, C.M.1    Poukalova, M.2
  • 31
    • 0027953497 scopus 로고
    • Effects of specimen load-bearing and free surface layers on the compressive mechanical properties of cellular materials
    • Zhu M., Keller T.S., et al. Effects of specimen load-bearing and free surface layers on the compressive mechanical properties of cellular materials. Journal of Biomechanics 1994, 27(1):57-66.
    • (1994) Journal of Biomechanics , vol.27 , Issue.1 , pp. 57-66
    • Zhu, M.1    Keller, T.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.