Volumn 7, Issue , 2008, Pages 418-420

Characterization and testing of a skin mimicking material for implantable antennas operating at ISM band (2.4 GHz-2.48 GHz)

Author keywords

Diethylene glycol butyl ether (DGBE); Implantable antenna; Industrial scientific and medical (ISM) band; Polyethylene glycol mono phenyl ether (Triton x 100); Skin mimicking material

Indexed keywords

BUTYL ETHER; CHARACTERIZATION AND TESTING; DIETHYLENE GLYCOL; DUAL BAND ANTENNAS; HUMAN SKIN; IMPLANTABLE ANTENNAS; IN-VITRO; INDUSTRIAL SCIENTIFIC AND MEDICAL; ISM BANDS; RELATIVE DIELECTRIC CONSTANT; TRANSMISSION CHARACTERISTICS; TRITON X-100;

EID: 77950664806     PISSN: 15361225     EISSN: None     Source Type: Journal    
DOI: 10.1109/LAWP.2008.2001736     Document Type: Article
Times cited : (90)

References (9)
  • 1
    • 4043097617 scopus 로고    scopus 로고
    • Design of an antenna for pacemaker communication
    • Mar.
    • C. M. Furse, "Design of an antenna for pacemaker communication," Microwaves RF, vol. 39, no. 3, pp. 73-76, Mar. 2000.
    • (2000) Microwaves RF , vol.39 , Issue.3 , pp. 73-76
    • Furse, C.M.1
  • 2
    • 0033331607 scopus 로고    scopus 로고
    • Subminiature implantable potentiostat and modified commercial telemetry device for remote glucose monitoring
    • Dec.
    • R. D. Beach, F. v. Kuster, and F. Moussy, "Subminiature implantable potentiostat and modified commercial telemetry device for remote glucose monitoring," IEEE Trans. Instr. Meas., vol. 48, no. 6, pp. 1239-1245, Dec. 1999.
    • (1999) IEEE Trans. Instr. Meas. , vol.48 , Issue.6 , pp. 1239-1245
    • Beach, R.D.1    Kuster, F.V.2    Moussy, F.3
  • 3
    • 13244255587 scopus 로고    scopus 로고
    • Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two- And threeelectrode biosensors
    • Feb.
    • R. D. Beach, R. W. Conlan, M. C. Godwin, and F. Moussy, "Towards a miniature implantable in vivo telemetry monitoring system dynamically configurable as a potentiostat or galvanostat for two- and threeelectrode biosensors," IEEE Trans. Instr. Meas., vol. 54, no. 1, pp. 61-72, Feb. 2005.
    • (2005) IEEE Trans. Instr. Meas. , vol.54 , Issue.1 , pp. 61-72
    • Beach, R.D.1    Conlan, R.W.2    Godwin, M.C.3    Moussy, F.4
  • 4
    • 4043153400 scopus 로고    scopus 로고
    • Design of implantable microstrip antennas for communication with medical implants
    • Aug.
    • P. Soontornpipit C. M. Furse, and Y. C. Chung, "Design of implantable microstrip antennas for communication with medical implants," IEEE Trans. Microw: Theory Tech., vol. 52, no. 8, pp. 1944-1951, Aug. 2004.
    • (2004) IEEE Trans. Microw: Theory Tech. , vol.52 , Issue.8 , pp. 1944-1951
    • Soontornpipit, P.1    Furse, C.M.2    Chung, Y.C.3
  • 5
    • 4043114097 scopus 로고    scopus 로고
    • Implanted antennas inside a human body: Simulations, designs, and characterizations
    • Aug.
    • J. Kim and Y. Rahmat-Samii, "Implanted antennas inside a human body: Simulations, designs, and characterizations," IEEE Trans. Microw. Theory Tech., vol. 52, no. 8, pp. 1934-1943, Aug. 2004.
    • (2004) IEEE Trans. Microw. Theory Tech. , vol.52 , Issue.8 , pp. 1934-1943
    • Kim, J.1    Rahmat-Samii, Y.2
  • 6
    • 27644526590 scopus 로고    scopus 로고
    • Impedance matching and implementation of planar space-filling dipoles as intraocular implanted antennas in a retinal prosthesis
    • Aug.
    • K. Gosalia, M. S. Humayun, and G. Lazzi, "Impedance matching and implementation of planar space-filling dipoles as intraocular implanted antennas in a retinal prosthesis," IEEE Trans. Antennas Propag., vol. 53, no. 8, pp. 2365-2373, Aug. 2005.
    • (2005) IEEE Trans. Antennas Propag. , vol.53 , Issue.8 , pp. 2365-2373
    • Gosalia, K.1    Humayun, M.S.2    Lazzi, G.3
  • 7
    • 41949142111 scopus 로고    scopus 로고
    • Design of a dual-band implantable antenna and development of skin mimicking gels for continuous glucose monitoring
    • Apr.
    • T. Karacolak, A. Z. Hood, and E. Topsakal, "Design of a dual-band implantable antenna and development of skin mimicking gels for continuous glucose monitoring," IEEE Trans. Microw. Theory Tech., vol. 56, no. 4, pp. 1001-1008, Apr. 2008.
    • (2008) IEEE Trans. Microw. Theory Tech. , vol.56 , Issue.4 , pp. 1001-1008
    • Karacolak, T.1    Hood, A.Z.2    Topsakal, E.3
  • 8
    • 0029954935 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: I. Literature survey
    • C. Gabriel, S. Gabriel, and E. Corthout, "The dielectric properties of biological tissues: I. Literature survey," Phys. Med. Biol., vol. 41, pp. 2231-2249, 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2231-2249
    • Gabriel, C.1    Gabriel, S.2    Corthout, E.3
  • 9
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
    • S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz," Phys. Med. Biol., vol. 41, pp. 2251-2269, 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.