A small-animal PET system based on LYSO crystal arrays, PS-PMTs and a PCI DAQ board

Author keywords

H8500; LYSO; PS PMT; Small animal PET

Indexed keywords

DEAD TIME; DETECTION MODULES; DIGITAL ACQUISITION; ENERGY RESOLUTIONS; FRONT END ELECTRONICS; GLASS CAPILLARIES; LYSO CRYSTALS; MAXIMUM VALUES; ME-XICO; MOUSE PHANTOMS; NOISE EQUIVALENT COUNT RATES; OUTPUT SIGNAL; PCI DAQ BOARDS; PEAK-TO-VALLEY RATIOS; POSITION SENSITIVE PHOTOMULTIPLIER TUBE; POSITRON EMISSION; READ-OUT CIRCUIT; SCATTER FRACTIONS; SIGNAL DIGITIZATION; SMALL ANIMAL; SMALL ANIMAL PET; SYSTEM SENSITIVITY; SYSTEM-BASED; TIMING RESOLUTIONS; VOLUME SOURCE;

EID: 77950654233     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2009.2038052     Document Type: Article
Times cited : (23)

References (34)
  • 1
    • 0026522954 scopus 로고
    • Design features and performance of a PET system for animal research
    • P. D. Cutler, S. R. Cherry, E. J. Hoffman, and W. M. Digby, "Design features and performance of a PET system for animal research," J. Nucl. Med., vol. 33, pp. 595-604, 1992.
    • (1992) J. Nucl. Med. , vol.33 , pp. 595-604
    • Cutler, P.D.1    Cherry, S.R.2    Hoffman, E.J.3    Digby, W.M.4
  • 3
    • 0028493624 scopus 로고
    • Design and engineering aspects of a high resolution positron tomograph for small animal imaging
    • Aug.
    • R. Lecomte, J. Cadorette, P. Richard, S. Rodriguez, and D. Rouleau, "Design and engineering aspects of a high resolution positron tomograph for small animal imaging," IEEE Trans. Nucl. Sci., vol. 41, no. 4, pp. 1446-1452, Aug. 1994.
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , Issue.4 , pp. 1446-1452
    • Lecomte, R.1    Cadorette, J.2    Richard, P.3    Rodriguez, S.4    Rouleau, D.5
  • 8
  • 9
    • 0032316712 scopus 로고    scopus 로고
    • YAP- PET: First results of a small animal positron emission tomograph based on YAP: Ce finger crystals
    • Dec.
    • A. Del Guerra, G. Di Domenico, M. Scandola, and G. Zavattini, "YAP- PET: First results of a small animal positron emission tomograph based on YAP: Ce finger crystals," IEEE Trans. Nucl. Sci., vol. 45, no. 6, pp. 3105-3108, Dec. 1998.
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , Issue.6 , pp. 3105-3108
    • Del Guerra, A.1    Di Domenico, G.2    Scandola, M.3    Zavattini, G.4
  • 13
    • 0032216607 scopus 로고    scopus 로고
    • Performance characteristics of a compact position-sensitive LSO detector module
    • J. J. Vaquero, J. Seidel, S. Siegel, W. R. Gandler, and M. V. Green, "Performance characteristics of a compact position-sensitive LSO detector module," IEEE Trans. Med. Imag., vol. 17, pp. 967-978, 1998.
    • (1998) IEEE Trans. Med. Imag. , vol.17 , pp. 967-978
    • Vaquero, J.J.1    Seidel, J.2    Siegel, S.3    Gandler, W.R.4    Green, M.V.5
  • 14
    • 0033343644 scopus 로고    scopus 로고
    • Development of a small animal PET imaging device with resolution approaching l mm
    • Jun.
    • J. A. Correia, C. A. Burnham, D. Kaufman, and A. J. Fischman, "Development of a small animal PET imaging device with resolution approaching l mm," IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 631-635, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 631-635
    • Correia, J.A.1    Burnham, C.A.2    Kaufman, D.3    Fischman, A.J.4
  • 16
    • 0037147906 scopus 로고    scopus 로고
    • Design and development of 1 mm resolution PET detectors with position-sensitive PMTs
    • Y. Shao, S. R. Cherry, and A. F. Chatziioannou, "Design and development of 1 mm resolution PET detectors with position-sensitive PMTs," Nucl. Instrum. Methods Phys. Res. A, vol. A477, pp. 486-490, 2002.
    • (2002) Nucl. Instrum. Methods Phys. Res. A , vol.A477 , pp. 486-490
    • Shao, Y.1    Cherry, S.R.2    Chatziioannou, A.F.3
  • 17
    • 0037151412 scopus 로고    scopus 로고
    • CMiCE: A high resolution animal PET using continuous LSO with a statistics based positioning scheme
    • J. Joung, R. S. Miyaoka, and T. K. Lewellen, "cMiCE: A high resolution animal PET using continuous LSO with a statistics based positioning scheme," Nucl. Instrum. Methods Phys. Res. A, vol. A489, pp. 584-598, 2002.
    • (2002) Nucl. Instrum. Methods Phys. Res. A , vol.A489 , pp. 584-598
    • Joung, J.1    Miyaoka, R.S.2    Lewellen, T.K.3
  • 23
    • 23844432630 scopus 로고    scopus 로고
    • Instrumentation aspects of animal PET
    • Y. C. Tai and R. Laforest, "Instrumentation aspects of animal PET," Annu. Rev. Biomed. Eng., vol. 7, pp. 255-285, 2005.
    • (2005) Annu. Rev. Biomed. Eng. , vol.7 , pp. 255-285
    • Tai, Y.C.1    Laforest, R.2
  • 24
    • 13244295721 scopus 로고    scopus 로고
    • Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors
    • M. S. Judenhofer, B. J. Pichler, and S. R. Cherry, "Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors," Phys. Med. Biol., vol. 50, pp. 29-44,2005.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 29-44
    • Judenhofer, M.S.1    Pichler, B.J.2    Cherry, S.R.3
  • 27
    • 0030164341 scopus 로고    scopus 로고
    • Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT
    • Jun.
    • S. Siegel, R. W. Silverman, Y. Shao, and S. R. Cherry, "Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT," IEEE Trans. Nucl. Sci., vol. 43,no.3,pp. 1634-1641, Jun. 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.3 , pp. 1634-1641
    • Siegel, S.1    Silverman, R.W.2    Shao, Y.3    Cherry, S.R.4
  • 28
    • 0024610834 scopus 로고
    • PET system calibrations and corrections for quantitative and spatially accurate images
    • Feb.
    • E. J. Hoffman, T. M. Guerrero, G. Germano, W. M. Digby, and M. Dahlbom, "PET system calibrations and corrections for quantitative and spatially accurate images," IEEE Trans. Nucl. Sci., vol. 36, no. 1, pp. 1108-1112, Feb. 1989.
    • (1989) IEEE Trans. Nucl. Sci. , vol.36 , Issue.1 , pp. 1108-1112
    • Hoffman, E.J.1    Guerrero, T.M.2    Germano, G.3    Digby, W.M.4    Dahlbom, M.5
  • 30
    • 34249921200 scopus 로고
    • A method for measuring the absolute sensitivity of positron emission tomographic scanners
    • D. L. Bailey, T. Jones, and T. J. Spinks, "A method for measuring the absolute sensitivity of positron emission tomographic scanners," Eur. J. Nucl. Med., vol. 18-6, pp. 374-379, 1991.
    • (1991) Eur. J. Nucl. Med. , vol.18 , Issue.6 , pp. 374-379
    • Bailey, D.L.1    Jones, T.2    Spinks, T.J.3
  • 31
    • 33645690906 scopus 로고    scopus 로고
    • Observations regarding scatter fraction and NEC measurements for small animal PET
    • Feb.
    • Y. Yang and S. R. Cherry, "Observations regarding scatter fraction and NEC measurements for small animal PET," IEEE Trans. Nucl. Sci., vol. 53, no. 1, pp. 127-132, Feb. 2006.
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , Issue.1 , pp. 127-132
    • Yang, Y.1    Cherry, S.R.2
  • 33
    • 0347848746 scopus 로고    scopus 로고
    • D. L. Bailey, D. W. Townsend, P. E. Valk, and M. N. Maisey, Eds., 1st ed. New York: Springer
    • Positron Emission Tomography: Basic Sciences, D. L. Bailey, D. W. Townsend, P. E. Valk, and M. N. Maisey, Eds., 1st ed. New York: Springer, 2005.
    • (2005) Positron Emission Tomography: Basic Sciences
  • 34
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional PET
    • M. E. Daube-Witherspoon and G. Muehllehner, "Treatment of axial data in three-dimensional PET," J. Nucl. Med., vol. 28, pp. 1717-1724, 1987.
    • (1987) J. Nucl. Med. , vol.28 , pp. 1717-1724
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.