메뉴 건너뛰기




Volumn 37, Issue 4, 2010, Pages 1565-1570

Technical note: Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry

Author keywords

Dosimetry; EBT; EBT2; Optical density; Radiochromic film

Indexed keywords

CALIBRATION; DENSITY (OPTICAL); DENSITY MEASUREMENT (OPTICAL); DOSIMETRY; ERRORS; SCANNING; TRANSMISSIONS;

EID: 77950579345     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3355895     Document Type: Article
Times cited : (48)

References (25)
  • 1
  • 2
    • 33646461862 scopus 로고    scopus 로고
    • Evaluation of GafChromic EBT prototype B for external beam dose verification
    • 0094-2405,. 10.1118/1.2188077
    • M. Todorovic, M. Fischer, F. Cremers, E. Thom, and R. Schmidt, " Evaluation of GafChromic EBT prototype B for external beam dose verification.," Med. Phys. 0094-2405 33, 1321-1328 (2006). 10.1118/1.2188077
    • (2006) Med. Phys. , vol.33 , pp. 1321-1328
    • Todorovic, M.1    Fischer, M.2    Cremers, F.3    Thom, E.4    Schmidt, R.5
  • 4
    • 27644471150 scopus 로고    scopus 로고
    • Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range
    • DOI 10.1016/j.apradiso.2005.07.002, PII S0969804305002332
    • M. J. Butson, T. Cheung, and P. K. N. Yu, " Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp x-ray range.," Appl. Radiat. Isot. 0969-8043 64 (1), 60-62 (2006). 10.1016/j.apradiso.2005.07. 002 (Pubitemid 41550172)
    • (2006) Applied Radiation and Isotopes , vol.64 , Issue.1 , pp. 60-62
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3
  • 5
    • 33845949969 scopus 로고    scopus 로고
    • Absorption spectroscopy of EBT model GAFCHROMIC™ film
    • DOI 10.1118/1.2400615
    • S. Devic, N. Tomic, Z. Pang, J. Seuntjens, E. B. Podgorsak, and C. G. Soares, " Absorption spectroscopy of EBT model GAFCHROMIC film.," Med. Phys. 0094-2405 34, 112-118 (2007). 10.1118/1.2400615 (Pubitemid 46035233)
    • (2007) Medical Physics , vol.34 , Issue.1 , pp. 112-118
    • Devic, S.1    Tomic, N.2    Pang, Z.3    Seuntjens, J.4    Podgorsak, E.B.5    Soares, C.G.6
  • 6
    • 28044452190 scopus 로고    scopus 로고
    • Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies
    • DOI 10.1118/1.2065467
    • S. -T. Chiu-Tsao, Y. Ho, R. Shankar, L. Wang, and L. B. Harrison, " Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies.," Med. Phys. 0094-2405 32, 3350-3354 (2005). 10.1118/1.2065467 (Pubitemid 41689286)
    • (2005) Medical Physics , vol.32 , Issue.11 , pp. 3350-3354
    • Chiu-Tsao, S.-T.1    Ho, Y.2    Shankar, R.3    Wang, L.4    Harrison, L.B.5
  • 7
    • 72049110767 scopus 로고    scopus 로고
    • Energy dependence of EBT-1 radiochromic film response for photon (10 kVp-15 MVp) and electron beams (6-18 MeV) readout by a flatbed scanner
    • 0094-2405,. 10.1118/1.3253902
    • C. Richter, J. Pawelke, L. Karsch, and J. Woithe, " Energy dependence of EBT-1 radiochromic film response for photon (10 kVp-15 MVp) and electron beams (6-18 MeV) readout by a flatbed scanner.," Med. Phys. 0094-2405 36, 5506-5514 (2009). 10.1118/1.3253902
    • (2009) Med. Phys. , vol.36 , pp. 5506-5514
    • Richter, C.1    Pawelke, J.2    Karsch, L.3    Woithe, J.4
  • 8
    • 33846582373 scopus 로고    scopus 로고
    • Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter
    • DOI 10.1118/1.2431425
    • A. Rink, I. A. Vitkin, and D. A. Jaffray, " Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter.," Med. Phys. 0094-2405 34, 458-463 (2007). 10.1118/1.2431425 (Pubitemid 46185123)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 458-463
    • Rink, A.1    Vitkin, I.A.2    Jaffray, D.A.3
  • 9
    • 33645519422 scopus 로고    scopus 로고
    • Accurate skin dose measurements using radiochromic film in clinical applications
    • 0094-2405,. 10.1118/1.2179169
    • S. Devic, J. Seuntjens, W. Abdel-Rahman, M. Evans, M. Olivares, E. B. Podgorsak, T. Vuong, and C. G. Soares, " Accurate skin dose measurements using radiochromic film in clinical applications.," Med. Phys. 0094-2405 33, 1116-1124 (2006). 10.1118/1.2179169
    • (2006) Med. Phys. , vol.33 , pp. 1116-1124
    • Devic, S.1    Seuntjens, J.2    Abdel-Rahman, W.3    Evans, M.4    Olivares, M.5    Podgorsak, E.B.6    Vuong, T.7    Soares, C.G.8
  • 10
    • 66449083249 scopus 로고    scopus 로고
    • Photon beam dosimetry in the superficial buildup region using radiochromic EBT film stack
    • 0094-2405,. 10.1118/1.3125134
    • S. -T. Chiu-Tsao and M. F. Chan, " Photon beam dosimetry in the superficial buildup region using radiochromic EBT film stack.," Med. Phys. 0094-2405 36, 2074-2083 (2009). 10.1118/1.3125134
    • (2009) Med. Phys. , vol.36 , pp. 2074-2083
    • Chiu-Tsao, S.-T.1    Chan, M.F.2
  • 11
    • 58149134060 scopus 로고    scopus 로고
    • In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques
    • 0094-2405,. 10.1118/1.3030951
    • Z. -Y. Qi, X. -W. Deng, S. -M. Huang, L. Zhang, Z. -C. He, X. A. Li, I. Kwan, M. Lerch, D. Cutajar, P. Metcalfe, and A. Rosenfeld, " In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques.," Med. Phys. 0094-2405 36, 59-70 (2009). 10.1118/1.3030951
    • (2009) Med. Phys. , vol.36 , pp. 59-70
    • Qi, Z.-Y.1    Deng, X.-W.2    Huang, S.-M.3    Zhang, L.4    He, Z.-C.5    Li, X.A.6    Kwan, I.7    Lerch, M.8    Cutajar, D.9    Metcalfe, P.10    Rosenfeld, A.11
  • 12
    • 23944476072 scopus 로고    scopus 로고
    • Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium
    • DOI 10.1118/1.1951447
    • A. Rink, I. A. Vitkin, and D. A. Jaffray, " Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium.," Med. Phys. 0094-2405 32, 2510-2516 (2005). 10.1118/1.1951447 (Pubitemid 41197188)
    • (2005) Medical Physics , vol.32 , Issue.8 , pp. 2510-2516
    • Rink, A.1    Alex Vitkin, I.2    Jaffray, D.A.3
  • 13
    • 52949149669 scopus 로고    scopus 로고
    • Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium
    • 0094-2405,. 10.1118/1.2975483
    • A. Rink, D. F. Lewis, S. Varma, I. A. Vitkin, and D. A. Jaffray, " Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium.," Med. Phys. 0094-2405 35, 4545-4555 (2008). 10.1118/1.2975483
    • (2008) Med. Phys. , vol.35 , pp. 4545-4555
    • Rink, A.1    Lewis, D.F.2    Varma, S.3    Vitkin, I.A.4    Jaffray, D.A.5
  • 14
    • 45749158708 scopus 로고    scopus 로고
    • An assessment of GafChromic film for measuring 50 kV and 100 kV percentage depth dose curves
    • DOI 10.1088/0031-9155/53/11/N02, PII S0031915508702124
    • C. L. Fletcher and J. A. Mills, " An assessment of GafChromic film for measuring 50 kV and 100 kV percentage depth dose curves.," Phys. Med. Biol. 0031-9155 53, N209-N218 (2008). 10.1088/0031-9155/53/11/N02 (Pubitemid 351868626)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.11
    • Fletcher, C.L.1    Mills, J.A.2
  • 15
    • 44649147011 scopus 로고    scopus 로고
    • Use of Gafchromic EBT films in heavy ion therapy
    • 0168-9002. 10.1016/j.nima.2008.03.088
    • M. Martišíková, B. Ackermanna, S. Klemma, and O. Jäkela, " Use of Gafchromic EBT films in heavy ion therapy.," Nucl. Instrum. Methods Phys. Res. A 0168-9002 591 (1), 171-173 (2008). 10.1016/j.nima.2008.03.088
    • (2008) Nucl. Instrum. Methods Phys. Res. A , vol.591 , Issue.1 , pp. 171-173
    • Martišíková, M.1    Ackermanna, B.2    Klemma, S.3    Jäkela, O.4
  • 16
    • 44449122864 scopus 로고    scopus 로고
    • Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife
    • DOI 10.1118/1.2912179
    • E. E. Wilcox and G. M. Daskalov, " Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife.," Med. Phys. 0094-2405 35, 2259-2266 (2008). 10.1118/1.2912179 (Pubitemid 351752943)
    • (2008) Medical Physics , vol.35 , Issue.6 , pp. 2259-2266
    • Wilcox, E.E.1    Daskalov, G.M.2
  • 17
    • 50449083499 scopus 로고    scopus 로고
    • Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM
    • 0094-2405,. 10.1118/1.2969070
    • I. J. Das, C.-W. Cheng, R. J. Watts, A. Ahnesjö, J. Gibbons, X. A. Li, J. Lowenstein, R. K. Mitra, W. E. Simon, and T. C. Zhu, " Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM.," Med. Phys. 0094-2405 35, 4186-4215 (2008). 10.1118/1.2969070
    • (2008) Med. Phys. , vol.35 , pp. 4186-4215
    • Das, I.J.1    Cheng, C.-W.2    Watts, R.J.3    Ahnesjö, A.4    Gibbons, J.5    Li, X.A.6    Lowenstein, J.7    Mitra, R.K.8    Simon, W.E.9    Zhu, T.C.10
  • 18
    • 66449085569 scopus 로고    scopus 로고
    • On the characterization and uncertainty analysis of radiochromic film dosimetry
    • 0094-2405,. 10.1118/1.3121488
    • H. Bouchard, F. Lacroix, G. Beaudoin, J. -F. Carrier, and I. Kawrakow, " On the characterization and uncertainty analysis of radiochromic film dosimetry.," Med. Phys. 0094-2405 36, 1931-1946 (2009). 10.1118/1.3121488
    • (2009) Med. Phys. , vol.36 , pp. 1931-1946
    • Bouchard, H.1    Lacroix, F.2    Beaudoin, G.3    Carrier, J.-F.4    Kawrakow, I.5
  • 19
    • 0031466420 scopus 로고    scopus 로고
    • GafChromic MD-55: Investigated as a precision dosimeter
    • DOI 10.1118/1.598106
    • N. V. Klassen, L. van der Zwan, and J. Cygler, " GafChromic MD-55: Investigated as a precision dosimeter.," Med. Phys. 0094-2405 24, 1924-1934 (1997). 10.1118/1.598106 (Pubitemid 28013507)
    • (1997) Medical Physics , vol.24 , Issue.12 , pp. 1924-1934
    • Klassen, N.V.1    Van Der Zwan, L.2    Cygler, J.3
  • 21
    • 85027230878 scopus 로고    scopus 로고
    • EBT2 White Paper, Revision 1, International Specialty Products, available at.
    • EBT2 White Paper, Revision 1, International Specialty Products, available at: www.gafchromic.com.
  • 22
    • 46149100990 scopus 로고    scopus 로고
    • GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis
    • DOI 10.1118/1.2938522
    • S. Saur and J. Frengen, " GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis.," Med. Phys. 0094-2405 35, 3094-3101 (2008). 10.1118/1.2938522 (Pubitemid 351904513)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3094-3101
    • Saur, S.1    Frengen, J.2
  • 24
    • 85027241717 scopus 로고    scopus 로고
    • Gafchromic EBT2 Scan Handling Guide, International Specialty Products, available at.
    • Gafchromic EBT2 Scan Handling Guide, International Specialty Products, available at: www.gafchromic.com.
  • 25
    • 33845329557 scopus 로고    scopus 로고
    • Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC® film
    • DOI 10.1118/1.2370505, 012612MPH
    • B. D. Lynch, J. Kozelka, M. K. Ranade, J. G. Li, W. E. Simon, and J. F. Dempsey, " Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.," Med. Phys. 0094-2405 33, 4551-4556 (2006). 10.1118/1.2370505 (Pubitemid 44868091)
    • (2006) Medical Physics , vol.33 , Issue.12 , pp. 4551-4556
    • Lynch, B.D.1    Kozelka, J.2    Ranade, M.K.3    Li, J.G.4    Simon, W.E.5    Dempsey, J.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.