-
1
-
-
85024787603
-
Characterization and use of EBT radiochromic film for IMRT dose verification
-
DOI 10.1118/1.2360012
-
O. A. Zeidan, S. A. L. Stephenson, S. L. Meeks, T. H. Wagner, T. R. Willoughby, P. A. Kupelian, and K. M. Langen, " Characterization and use of EBT radiochromic film for IMRT dose verification.," Med. Phys. 0094-2405 33, 4064-4072 (2006). 10.1118/1.2360012 (Pubitemid 44673098)
-
(2006)
Medical Physics
, vol.33
, Issue.11
, pp. 4064-4072
-
-
Zeidan, O.A.1
Stephenson, S.A.L.2
Meeks, S.L.3
Wagner, T.H.4
Willoughby, T.R.5
Kupelian, P.A.6
Langen, K.M.7
-
2
-
-
33646461862
-
Evaluation of GafChromic EBT prototype B for external beam dose verification
-
0094-2405,. 10.1118/1.2188077
-
M. Todorovic, M. Fischer, F. Cremers, E. Thom, and R. Schmidt, " Evaluation of GafChromic EBT prototype B for external beam dose verification.," Med. Phys. 0094-2405 33, 1321-1328 (2006). 10.1118/1.2188077
-
(2006)
Med. Phys.
, vol.33
, pp. 1321-1328
-
-
Todorovic, M.1
Fischer, M.2
Cremers, F.3
Thom, E.4
Schmidt, R.5
-
3
-
-
0008796868
-
Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55
-
DOI 10.1118/1.598407
-
A. Niroomand-Rad, C. R. Blackwell, B. M. Coursey, K. P. Gall, J. M. Galvin, W. L. McLaughlin, A. S. Meigooni, R. Nath, J. E. Rodgers, and C. G. Soares, " Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55.," Med. Phys. 0094-2405 25, 2093-2115 (1998). 10.1118/1.598407 (Pubitemid 28530099)
-
(1998)
Medical Physics
, vol.25
, Issue.11
, pp. 2093-2115
-
-
Niroomand-Rad, A.1
Blackwell, C.R.2
Coursey, B.M.3
Gall, K.P.4
Galvin, J.M.5
McLaughlin, W.L.6
Meigooni, A.S.7
Nath, R.8
Rodgers, J.E.9
Soares, C.G.10
-
4
-
-
27644471150
-
Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range
-
DOI 10.1016/j.apradiso.2005.07.002, PII S0969804305002332
-
M. J. Butson, T. Cheung, and P. K. N. Yu, " Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp x-ray range.," Appl. Radiat. Isot. 0969-8043 64 (1), 60-62 (2006). 10.1016/j.apradiso.2005.07. 002 (Pubitemid 41550172)
-
(2006)
Applied Radiation and Isotopes
, vol.64
, Issue.1
, pp. 60-62
-
-
Butson, M.J.1
Cheung, T.2
Yu, P.K.N.3
-
5
-
-
33845949969
-
Absorption spectroscopy of EBT model GAFCHROMIC™ film
-
DOI 10.1118/1.2400615
-
S. Devic, N. Tomic, Z. Pang, J. Seuntjens, E. B. Podgorsak, and C. G. Soares, " Absorption spectroscopy of EBT model GAFCHROMIC film.," Med. Phys. 0094-2405 34, 112-118 (2007). 10.1118/1.2400615 (Pubitemid 46035233)
-
(2007)
Medical Physics
, vol.34
, Issue.1
, pp. 112-118
-
-
Devic, S.1
Tomic, N.2
Pang, Z.3
Seuntjens, J.4
Podgorsak, E.B.5
Soares, C.G.6
-
6
-
-
28044452190
-
Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies
-
DOI 10.1118/1.2065467
-
S. -T. Chiu-Tsao, Y. Ho, R. Shankar, L. Wang, and L. B. Harrison, " Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies.," Med. Phys. 0094-2405 32, 3350-3354 (2005). 10.1118/1.2065467 (Pubitemid 41689286)
-
(2005)
Medical Physics
, vol.32
, Issue.11
, pp. 3350-3354
-
-
Chiu-Tsao, S.-T.1
Ho, Y.2
Shankar, R.3
Wang, L.4
Harrison, L.B.5
-
7
-
-
72049110767
-
Energy dependence of EBT-1 radiochromic film response for photon (10 kVp-15 MVp) and electron beams (6-18 MeV) readout by a flatbed scanner
-
0094-2405,. 10.1118/1.3253902
-
C. Richter, J. Pawelke, L. Karsch, and J. Woithe, " Energy dependence of EBT-1 radiochromic film response for photon (10 kVp-15 MVp) and electron beams (6-18 MeV) readout by a flatbed scanner.," Med. Phys. 0094-2405 36, 5506-5514 (2009). 10.1118/1.3253902
-
(2009)
Med. Phys.
, vol.36
, pp. 5506-5514
-
-
Richter, C.1
Pawelke, J.2
Karsch, L.3
Woithe, J.4
-
8
-
-
33846582373
-
Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter
-
DOI 10.1118/1.2431425
-
A. Rink, I. A. Vitkin, and D. A. Jaffray, " Energy dependence (75 kVp to 18 MV) of radiochromic films assessed using a real-time optical dosimeter.," Med. Phys. 0094-2405 34, 458-463 (2007). 10.1118/1.2431425 (Pubitemid 46185123)
-
(2007)
Medical Physics
, vol.34
, Issue.2
, pp. 458-463
-
-
Rink, A.1
Vitkin, I.A.2
Jaffray, D.A.3
-
9
-
-
33645519422
-
Accurate skin dose measurements using radiochromic film in clinical applications
-
0094-2405,. 10.1118/1.2179169
-
S. Devic, J. Seuntjens, W. Abdel-Rahman, M. Evans, M. Olivares, E. B. Podgorsak, T. Vuong, and C. G. Soares, " Accurate skin dose measurements using radiochromic film in clinical applications.," Med. Phys. 0094-2405 33, 1116-1124 (2006). 10.1118/1.2179169
-
(2006)
Med. Phys.
, vol.33
, pp. 1116-1124
-
-
Devic, S.1
Seuntjens, J.2
Abdel-Rahman, W.3
Evans, M.4
Olivares, M.5
Podgorsak, E.B.6
Vuong, T.7
Soares, C.G.8
-
10
-
-
66449083249
-
Photon beam dosimetry in the superficial buildup region using radiochromic EBT film stack
-
0094-2405,. 10.1118/1.3125134
-
S. -T. Chiu-Tsao and M. F. Chan, " Photon beam dosimetry in the superficial buildup region using radiochromic EBT film stack.," Med. Phys. 0094-2405 36, 2074-2083 (2009). 10.1118/1.3125134
-
(2009)
Med. Phys.
, vol.36
, pp. 2074-2083
-
-
Chiu-Tsao, S.-T.1
Chan, M.F.2
-
11
-
-
58149134060
-
In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques
-
0094-2405,. 10.1118/1.3030951
-
Z. -Y. Qi, X. -W. Deng, S. -M. Huang, L. Zhang, Z. -C. He, X. A. Li, I. Kwan, M. Lerch, D. Cutajar, P. Metcalfe, and A. Rosenfeld, " In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques.," Med. Phys. 0094-2405 36, 59-70 (2009). 10.1118/1.3030951
-
(2009)
Med. Phys.
, vol.36
, pp. 59-70
-
-
Qi, Z.-Y.1
Deng, X.-W.2
Huang, S.-M.3
Zhang, L.4
He, Z.-C.5
Li, X.A.6
Kwan, I.7
Lerch, M.8
Cutajar, D.9
Metcalfe, P.10
Rosenfeld, A.11
-
12
-
-
23944476072
-
Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium
-
DOI 10.1118/1.1951447
-
A. Rink, I. A. Vitkin, and D. A. Jaffray, " Characterization and real-time optical measurements of the ionizing radiation dose response for a new radiochromic medium.," Med. Phys. 0094-2405 32, 2510-2516 (2005). 10.1118/1.1951447 (Pubitemid 41197188)
-
(2005)
Medical Physics
, vol.32
, Issue.8
, pp. 2510-2516
-
-
Rink, A.1
Alex Vitkin, I.2
Jaffray, D.A.3
-
13
-
-
52949149669
-
Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium
-
0094-2405,. 10.1118/1.2975483
-
A. Rink, D. F. Lewis, S. Varma, I. A. Vitkin, and D. A. Jaffray, " Temperature and hydration effects on absorbance spectra and radiation sensitivity of a radiochromic medium.," Med. Phys. 0094-2405 35, 4545-4555 (2008). 10.1118/1.2975483
-
(2008)
Med. Phys.
, vol.35
, pp. 4545-4555
-
-
Rink, A.1
Lewis, D.F.2
Varma, S.3
Vitkin, I.A.4
Jaffray, D.A.5
-
14
-
-
45749158708
-
An assessment of GafChromic film for measuring 50 kV and 100 kV percentage depth dose curves
-
DOI 10.1088/0031-9155/53/11/N02, PII S0031915508702124
-
C. L. Fletcher and J. A. Mills, " An assessment of GafChromic film for measuring 50 kV and 100 kV percentage depth dose curves.," Phys. Med. Biol. 0031-9155 53, N209-N218 (2008). 10.1088/0031-9155/53/11/N02 (Pubitemid 351868626)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.11
-
-
Fletcher, C.L.1
Mills, J.A.2
-
15
-
-
44649147011
-
Use of Gafchromic EBT films in heavy ion therapy
-
0168-9002. 10.1016/j.nima.2008.03.088
-
M. Martišíková, B. Ackermanna, S. Klemma, and O. Jäkela, " Use of Gafchromic EBT films in heavy ion therapy.," Nucl. Instrum. Methods Phys. Res. A 0168-9002 591 (1), 171-173 (2008). 10.1016/j.nima.2008.03.088
-
(2008)
Nucl. Instrum. Methods Phys. Res. A
, vol.591
, Issue.1
, pp. 171-173
-
-
Martišíková, M.1
Ackermanna, B.2
Klemma, S.3
Jäkela, O.4
-
16
-
-
44449122864
-
Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife
-
DOI 10.1118/1.2912179
-
E. E. Wilcox and G. M. Daskalov, " Accuracy of dose measurements and calculations within and beyond heterogeneous tissues for 6 MV photon fields smaller than 4 cm produced by Cyberknife.," Med. Phys. 0094-2405 35, 2259-2266 (2008). 10.1118/1.2912179 (Pubitemid 351752943)
-
(2008)
Medical Physics
, vol.35
, Issue.6
, pp. 2259-2266
-
-
Wilcox, E.E.1
Daskalov, G.M.2
-
17
-
-
50449083499
-
Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM
-
0094-2405,. 10.1118/1.2969070
-
I. J. Das, C.-W. Cheng, R. J. Watts, A. Ahnesjö, J. Gibbons, X. A. Li, J. Lowenstein, R. K. Mitra, W. E. Simon, and T. C. Zhu, " Accelerator beam data commissioning equipment and procedures: Report of the TG-106 of the Therapy Physics Committee of the AAPM.," Med. Phys. 0094-2405 35, 4186-4215 (2008). 10.1118/1.2969070
-
(2008)
Med. Phys.
, vol.35
, pp. 4186-4215
-
-
Das, I.J.1
Cheng, C.-W.2
Watts, R.J.3
Ahnesjö, A.4
Gibbons, J.5
Li, X.A.6
Lowenstein, J.7
Mitra, R.K.8
Simon, W.E.9
Zhu, T.C.10
-
18
-
-
66449085569
-
On the characterization and uncertainty analysis of radiochromic film dosimetry
-
0094-2405,. 10.1118/1.3121488
-
H. Bouchard, F. Lacroix, G. Beaudoin, J. -F. Carrier, and I. Kawrakow, " On the characterization and uncertainty analysis of radiochromic film dosimetry.," Med. Phys. 0094-2405 36, 1931-1946 (2009). 10.1118/1.3121488
-
(2009)
Med. Phys.
, vol.36
, pp. 1931-1946
-
-
Bouchard, H.1
Lacroix, F.2
Beaudoin, G.3
Carrier, J.-F.4
Kawrakow, I.5
-
19
-
-
0031466420
-
GafChromic MD-55: Investigated as a precision dosimeter
-
DOI 10.1118/1.598106
-
N. V. Klassen, L. van der Zwan, and J. Cygler, " GafChromic MD-55: Investigated as a precision dosimeter.," Med. Phys. 0094-2405 24, 1924-1934 (1997). 10.1118/1.598106 (Pubitemid 28013507)
-
(1997)
Medical Physics
, vol.24
, Issue.12
, pp. 1924-1934
-
-
Klassen, N.V.1
Van Der Zwan, L.2
Cygler, J.3
-
21
-
-
85027230878
-
-
EBT2 White Paper, Revision 1, International Specialty Products, available at.
-
EBT2 White Paper, Revision 1, International Specialty Products, available at: www.gafchromic.com.
-
-
-
-
22
-
-
46149100990
-
GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis
-
DOI 10.1118/1.2938522
-
S. Saur and J. Frengen, " GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis.," Med. Phys. 0094-2405 35, 3094-3101 (2008). 10.1118/1.2938522 (Pubitemid 351904513)
-
(2008)
Medical Physics
, vol.35
, Issue.7
, pp. 3094-3101
-
-
Saur, S.1
Frengen, J.2
-
23
-
-
4644295382
-
Dosimetric properties of improved GafChromic films for seven different digitizers
-
DOI 10.1118/1.1776691
-
S. Devic, J. Seuntjens, G. Hegyi, E. B. Podgorsak, C. G. Soares, A. S. Kirov, I. Ali, J. F. Williamson, and A. Elizondo, " Dosimetric properties of improved GafChromic films for seven different digitizers.," Med. Phys. 0094-2405 31, 2392-2401 (2004). 10.1118/1.1776691 (Pubitemid 39287852)
-
(2004)
Medical Physics
, vol.31
, Issue.9
, pp. 2392-2401
-
-
Devic, S.1
Seuntjens, J.2
Hegyi, G.3
Podgorsak, E.B.4
Soares, C.G.5
Kirov, A.S.6
Ali, I.7
Williamson, J.F.8
Elizondo, A.9
-
24
-
-
85027241717
-
-
Gafchromic EBT2 Scan Handling Guide, International Specialty Products, available at.
-
Gafchromic EBT2 Scan Handling Guide, International Specialty Products, available at: www.gafchromic.com.
-
-
-
-
25
-
-
33845329557
-
Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC® film
-
DOI 10.1118/1.2370505, 012612MPH
-
B. D. Lynch, J. Kozelka, M. K. Ranade, J. G. Li, W. E. Simon, and J. F. Dempsey, " Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.," Med. Phys. 0094-2405 33, 4551-4556 (2006). 10.1118/1.2370505 (Pubitemid 44868091)
-
(2006)
Medical Physics
, vol.33
, Issue.12
, pp. 4551-4556
-
-
Lynch, B.D.1
Kozelka, J.2
Ranade, M.K.3
Li, J.G.4
Simon, W.E.5
Dempsey, J.F.6
|