Investigation of the effect of anode/filter materials on the dose and image quality of a digital mammography system based on an amorphous selenium flat panel detector

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BREAST; COMPUTER SYSTEM; CONTROLLED STUDY; DIGITAL MAMMOGRAPHY; IMAGE QUALITY; MAMMARY GLAND; THICKNESS;

EID: 77950565908     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/60404532     Document Type: Article
Times cited : (43)

References (12)
  • 1
    • 0033693797 scopus 로고    scopus 로고
    • Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: A Monte Carlo study
    • Dance DR, Thilander Klang A, Sandborg M, Skinner CL, Castellano Smith IA, Carlsson GA. Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study. Br J Radiol 2000;73:1056-1067
    • (2000) Br J Radiol , vol.73 , pp. 1056-1067
    • Dance, D.R.1    Thilander Klang, A.2    Sandborg, M.3    Skinner, C.L.4    Castellano Smith, I.A.5    Carlsson, G.A.6
  • 2
    • 33745393884 scopus 로고    scopus 로고
    • Optimization of tungsten X-ray spectra for digital mammography: A comparison of model to experiment
    • Andre MP, Spivey BA. Optimization of tungsten X-ray spectra for digital mammography: a comparison of model to experiment. Proc SPIE 1997;3032:411-418
    • (1997) Proc SPIE , vol.3032 , pp. 411-418
    • Andre, M.P.1    Spivey, B.A.2
  • 3
    • 0028001034 scopus 로고
    • Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness, and lesion type
    • DOI 10.1118/1.597191
    • Fahrig R, Yaffe MJ. Optimization of spectral shape in digital mammography: dependence on anode material, breast thickness and lesion type. Med Phys 1994;21:1473-1481 (Pubitemid 24307965)
    • (1994) Medical Physics , vol.21 , Issue.9 , pp. 1473-1481
    • Fahrig, R.1    Yaffe, M.J.2
  • 4
    • 0028145652 scopus 로고
    • A model for optimization of spectral shape in digital mammography
    • DOI 10.1118/1.597406
    • Fahrig R, Yaffe MJ. A model for optimization of spectral shape in digital mammography. Med Phys 1994;21:1463-1471 (Pubitemid 24307964)
    • (1994) Medical Physics , vol.21 , Issue.9 , pp. 1463-1471
    • Fahrig, R.1    Yaffe, M.J.2
  • 5
    • 0042878300 scopus 로고    scopus 로고
    • Optimal radiographic techniques for digital mammograms obtained with an amorphous selenium detector
    • Flynn M, Dodge C, Peck D, Swinford A. Optimal radiographic techniques for digital mammograms obtained with an amorphous selenium detector. Proc SPIE 2003;5030:147-156
    • (2003) Proc SPIE , vol.5030 , pp. 147-156
    • Flynn, M.1    Dodge, C.2    Peck, D.3    Swinford, A.4
  • 6
    • 33750547597 scopus 로고    scopus 로고
    • X-ray spectrum optimization of full-field digital mammography: Simulation and phantom study
    • DOI 10.1118/1.2351951
    • Bernhardt P, Mertelmeier T, Hoheisel M. X-ray spectrum optimization of full-digital mammography: simulation and phantom study. Med Phys 2006;33:4337-4349 (Pubitemid 44673124)
    • (2006) Medical Physics , vol.33 , Issue.11 , pp. 4337-4349
    • Bernhardt, P.1    Mertelmeier, T.2    Hoheisel, M.3
  • 7
    • 34548104947 scopus 로고    scopus 로고
    • Experimental investigation on the choice of the tungsten/rhodium anode/ filter combination for an amorphous selenium-based digital mammography system
    • DOI 10.1007/s00330-006-0574-x
    • Toroi P, Zanca F, Young KC, van Ongeval C, Marchal G, Bosmans H. Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system. Eur Radiol 2007;17:2368-2375 (Pubitemid 47288275)
    • (2007) European Radiology , vol.17 , Issue.9 , pp. 2368-2375
    • Toroi, P.1    Zanca, F.2    Young, K.C.3    Van Ongeval, C.4    Marchal, G.5    Bosmans, H.6
  • 10
    • 0033778108 scopus 로고    scopus 로고
    • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol
    • Dance DR, Skinner CL, Young KC, Beckett JR, Kotre CJ. Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol. Phys Med Biol 2000;45:3225-3240
    • (2000) Phys Med Biol , vol.45 , pp. 3225-3240
    • Dance, D.R.1    Skinner, C.L.2    Young, K.C.3    Beckett, J.R.4    Kotre, C.J.5
  • 12
    • 77950567503 scopus 로고    scopus 로고
    • Radiographic technique optimization for an amorphous selenium FFDM system: Phantom measurements and initial patient results
    • Lo JY, Samei E, Jesneck JL, Dobbins III JT, Baker JA, Singh S, et al. Radiographic technique optimization for an amorphous selenium FFDM system: phantom measurements and initial patient results. Proceedings of the IWDM 2004;31-36
    • (2004) Proceedings of the IWDM , pp. 31-36
    • Lo, J.Y.1    Samei, E.2    Jesneck, J.L.3    Dobbins Iii, J.T.4    Baker, J.A.5    Singh, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.