메뉴 건너뛰기




Volumn 3032, Issue , 1997, Pages 411-418

Optimization of tungsten x-ray spectra for digital mammography: A comparison of model to experiment

Author keywords

Beam filtration; Computational model; Digital mammography; Dose; Optimization; X ray spectra

Indexed keywords

CAMERAS; CHARGE COUPLED DEVICES; DIAGNOSTIC RADIOGRAPHY; DIGITAL CAMERAS; MOLYBDENUM; OPTIMIZATION; POROUS MATERIALS; QUANTUM EFFICIENCY; RHODIUM; SEMICONDUCTOR QUANTUM DOTS; SENSORS; SIGNAL TO NOISE RATIO; SILVER; TARGETS; TIN; TUBES (COMPONENTS); TUNGSTEN; X RAY ANALYSIS; X RAY SPECTROGRAPHS; X RAY TUBES; X RAYS;

EID: 33745393884     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.274009     Document Type: Conference Paper
Times cited : (15)

References (10)
  • 1
    • 0026483602 scopus 로고
    • Optimization of peak kilovoltage and spectral shape for digital mammography
    • R. Fahrig, A. Maidment, M. Yaffe, "Optimization of peak kilovoltage and spectral shape for digital mammography", SPIE Medical Imaging VI: Instrumentation 1651, pp. 74-83, 1992.
    • (1992) SPIE Medical Imaging VI: Instrumentation , vol.1651 , pp. 74-83
    • Fahrig, R.1    Maidment, A.2    Yaffe, M.3
  • 2
    • 0010403018 scopus 로고
    • Full-view digital mammography with a small-field image-stitching approach: Image quality and initial clinical results
    • PP
    • M. André, L. Olson, B. Spivey, M. Ysrael, J. Tran, "Full-view digital mammography with a small-field image-stitching approach: Image quality and initial clinical results", Radiology 193(P), PP. 476, 1994.
    • (1994) Radiology , vol.193 , Issue.P , pp. 476
    • André, M.1    Olson, L.2    Spivey, B.3    Ysrael, M.4    Tran, J.5
  • 3
    • 58749101271 scopus 로고
    • Model for computing tungsten tube spectra and mammographic dose for digital mammography
    • B. Spivey, M. André, M. Stoller, J. Tran, "Model for computing tungsten tube spectra and mammographic dose for digital mammography", Radiology 197(P), pp. 291, 1995.
    • (1995) Radiology , vol.197 , Issue.P , pp. 291
    • Spivey, B.1    André, M.2    Stoller, M.3    Tran, J.4
  • 4
    • 84970400213 scopus 로고
    • Über das kontinuierliche Rontgenspektrum
    • H. Kulenkampff, "Über das kontinuierliche Rontgenspektrum" , Ann. Phys. Leipzig 69, pp. 548-596, 1922.
    • (1922) Ann. Phys. Leipzig , vol.69 , pp. 548-596
    • Kulenkampff, H.1
  • 5
    • 0000599583 scopus 로고
    • On the theory of x-ray absorption and of the continuous x-ray spectrum
    • H. Kramers, "On the theory of x-ray absorption and of the continuous x-ray spectrum", Philos. Mag. 36, pp. 836-871, 1923.
    • (1923) Philos. Mag , vol.36 , pp. 836-871
    • Kramers, H.1
  • 6
    • 33744557373 scopus 로고
    • The effect of target absorption on the attenuation characteristics of bremmstrahlung generated at constant medium potentials
    • B. Soole, "The effect of target absorption on the attenuation characteristics of bremmstrahlung generated at constant medium potentials", J. Phys. B: Atom. Mol. Phys. 5, pp. 1583-1595, 1972.
    • (1972) J. Phys. B: Atom. Mol. Phys , vol.5 , pp. 1583-1595
    • Soole, B.1
  • 7
    • 0003966102 scopus 로고
    • National Bureau of Standards
    • M. Berger, J. Hubbel, "XCOM", National Bureau of Standards, 1987.
    • (1987) XCOM
    • Berger, M.1    Hubbel, J.2
  • 8
    • 0025756532 scopus 로고
    • Semi-empirical model for generating tungsten target x-ray spectra
    • D. Tucker, G. Barnes, D. Chakraborty, "Semi-empirical model for generating tungsten target x-ray spectra", Medical Physics 18(2), pp. 211-218, 1991.
    • (1991) Medical Physics , vol.18 , Issue.2 , pp. 211-218
    • Tucker, D.1    Barnes, G.2    Chakraborty, D.3
  • 9
    • 0025967743 scopus 로고
    • Spectral dependence of glandular tissue dose in screen-film mammography
    • X. Wu, G. Barnes, D. Tucker, "Spectral dependence of glandular tissue dose in screen-film mammography", Radiology 179, pp. 143-148, 1991.
    • (1991) Radiology , vol.179 , pp. 143-148
    • Wu, X.1    Barnes, G.2    Tucker, D.3
  • 10
    • 0028001034 scopus 로고
    • Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness, and lesion type
    • R. Fahrig, M. Yaffe, "Optimization of spectral shape in digital mammography: Dependence on anode material, breast thickness, and lesion type", Medical Physics 21(9), pp. 1473-1481, 1994.
    • (1994) Medical Physics , vol.21 , Issue.9 , pp. 1473-1481
    • Fahrig, R.1    Yaffe, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.