Evaluation of an a-Si EPID in direct detection configuration as a water-equivalent dosimeter for transit dosimetry

Author keywords

Amorphous silicon; Direct detection configuration; EPID; Transit dosimetry

Indexed keywords

CHEMICALS REMOVAL (WATER TREATMENT); COPPER; DOSIMETERS; DOSIMETRY; IONIZATION CHAMBERS; IONIZATION OF LIQUIDS; LIGHT EMISSION; LIGHT SCATTERING; PHANTOMS; PHOSPHORS; RADIATION EFFECTS; WATER TANKS;

EID: 77950553203     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3327456     Document Type: Article
Times cited : (30)

References (34)
  • 1
    • 0027141513 scopus 로고
    • Measurement possibilities using an electronic portal imaging device
    • DOI 10.1016/0167-8140(93)90253-5
    • M. C. Kirby and P. C. Williams, " Measurement possibilities using an electronic portal imaging device.," Radiother. Oncol. 0167-8140 29 (2), 237-243 (1993). 10.1016/0167-8140(93)90253-5 (Pubitemid 24007865)
    • (1993) Radiotherapy and Oncology , vol.29 , Issue.2 , pp. 237-243
    • Kirby, M.C.1    Williams, P.C.2
  • 2
    • 0029153633 scopus 로고
    • Portal dosimetry using a liquid ion chamber matrix: Dose response studies
    • 0094-2405. 10.1118/1.597502
    • Y. Zhu, X. Jiang, and J. Van Dyk, " Portal dosimetry using a liquid ion chamber matrix: Dose response studies.," Med. Phys. 0094-2405 22 (7), 1101-1106 (1995). 10.1118/1.597502
    • (1995) Med. Phys. , vol.22 , Issue.7 , pp. 1101-1106
    • Zhu, Y.1    Jiang, X.2    Van Dyk, J.3
  • 3
    • 34247516976 scopus 로고    scopus 로고
    • Daily monitoring of linear accelerator beam parameters using an amorphous silicon EPID
    • DOI 10.1088/0031-9155/52/6/012, PII S0031915507320434, 012
    • G. L. Budgell, R. Zhang, and R. I. Mackay, " Daily monitoring of linear accelerator beam parameters using an amorphous silicon EPID.," Phys. Med. Biol. 0031-9155 52, 1721-1733 (2007). 10.1088/0031-9155/52/6/012 (Pubitemid 46646377)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.6 , pp. 1721-1733
    • Budgell, G.J.1    Zhang, R.2    Mackay, R.I.3
  • 4
    • 0034505460 scopus 로고    scopus 로고
    • Testing of the stability of intensity modulated beams generated with dynamic multileaf collimation, applied to the MM50 Racetrack Microtron
    • DOI 10.1118/1.1326450
    • M. L. Dirkx and B. J. Heijmen, " Testing of the stability of intensity modulated beams generated with dynamic multileaf collimation, applied to the MM50 racetrack microtron.," Med. Phys. 0094-2405 27, 2701-2707 (2000). 10.1118/1.1326450 (Pubitemid 32063449)
    • (2000) Medical Physics , vol.27 , Issue.12 , pp. 2701-2707
    • Dirkx, M.L.P.1    Heijmen, B.J.M.2
  • 5
    • 0002781107 scopus 로고    scopus 로고
    • Megavoltage radiography for treatment verification
    • in, edited by J. Van Dyk (Medical Physics Publishing, Madison).
    • P. Munro, " Megavoltage radiography for treatment verification.," in The Modern Technology of Radiation Oncology, edited by, J. Van Dyk, (Medical Physics Publishing, Madison, 1999).
    • (1999) The Modern Technology of Radiation Oncology
    • Munro, P.1
  • 6
    • 0028149975 scopus 로고
    • A technique of automating compensator design for lung inhomogeneity correction using an electron portal imaging device
    • DOI 10.1118/1.597273
    • F. F. Yin, M. C. Schell, and P. Rubin, " A technique of automatic compensator design for lung inhomogenities correction using an electronic portal imaging device.," Med. Phys. 0094-2405 21, 1729-1732 (1994). 10.1118/1.597273 (Pubitemid 24356292)
    • (1994) Medical Physics , vol.21 , Issue.11 , pp. 1729-1732
    • Yin, F.-F.1    Schell, M.C.2    Rubin, P.3
  • 7
    • 0028803297 scopus 로고
    • Evaluation of electronic portal imaging device for missing tissue compensator design and verification
    • 0094-2405,. 10.1118/1.597647
    • D. M. Roback and B. J. Gerbi, " Evaluation of electronic portal imaging device for missing tissue compensator design and verification.," Med. Phys. 0094-2405 22, 2029-2034 (1995). 10.1118/1.597647
    • (1995) Med. Phys. , vol.22 , pp. 2029-2034
    • Roback, D.M.1    Gerbi, B.J.2
  • 8
    • 0032816409 scopus 로고    scopus 로고
    • Evaluation of an electronic portal imaging device for transit dosimetry
    • DOI 10.1080/028418699431177
    • X. He, A. Van Esch, R. Reyman, and D. Huyskens, " Evaluation of an electronic portal imaging device for transit dosimetry.," Acta Oncol. (Madr) 0001-6381 38 (5), 591-596 (1999). (Pubitemid 29333739)
    • (1999) Acta Oncologica , vol.38 , Issue.5 , pp. 591-596
    • He, X.1    Van Esch, A.2    Reymen, R.3    Huyskens, D.4
  • 9
    • 0347625746 scopus 로고    scopus 로고
    • Dosimetric IMRT verification with a flat-panel EPID
    • DOI 10.1118/1.1625440
    • B. Warkentin, S. Steciw, S. Rathee, and B. G. Fallone, " Dosimetric IMRT verification with a flat panel EPID.," Med. Phys. 0094-2405 30 (12), 3143-3155 (2003). 10.1118/1.1625440 (Pubitemid 37553755)
    • (2003) Medical Physics , vol.30 , Issue.12 , pp. 3143-3155
    • Warkentin, B.1    Steciw, S.2    Rathee, S.3    Fallone, B.G.4
  • 10
    • 1942478371 scopus 로고    scopus 로고
    • The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields
    • DOI 10.1016/j.radonc.2004.02.018, PII S016781400400088X
    • A. Van Esch, T. Depuydt, and D. P. Huyskens, " The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields.," Radiother. Oncol. 0167-8140 71, 223-234 (2004). 10.1016/j.radonc.2004.02.018 (Pubitemid 38521192)
    • (2004) Radiotherapy and Oncology , vol.71 , Issue.2 , pp. 223-234
    • Van Esch, A.1    Depuydt, T.2    Huyskens, D.P.3
  • 11
    • 33749393203 scopus 로고    scopus 로고
    • Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification
    • DOI 10.1118/1.2230810
    • L. N. McDermott, M. Wendling, B. van Asselen, J. Stroom, J. J. Sonke, M. van Herk, and B. J. Mijnheer, " Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.," Med. Phys. 0094-2405 33, 3921-3930 (2006). 10.1118/1.2230810 (Pubitemid 44505114)
    • (2006) Medical Physics , vol.33 , Issue.10 , pp. 3921-3930
    • McDermott, L.N.1    Wendling, M.2    Van Asselen, B.3    Stroom, J.4    Sonke, J.-J.5    Van Herk, M.6    Mijnheer, B.J.7
  • 12
    • 33750554055 scopus 로고    scopus 로고
    • Pretreatment verification of IMRT absolute dose distributions using a commercial a-Si EPID
    • DOI 10.1118/1.2357834
    • C. Talamonti, M. Casati, and M. Bucciolini, " Pretreatment verification of IMRT absolute dose distributions using a commercial a-Si EPID.," Med. Phys. 0094-2405 33, 4367-4378 (2006). 10.1118/1.2357834 (Pubitemid 44673126)
    • (2006) Medical Physics , vol.33 , Issue.11 , pp. 4367-4378
    • Talamonti, C.1    Casati, M.2    Bucciolini, M.3
  • 13
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • 0360-3016,. 10.1016/0360-3016(94)00388-2
    • M. C. Kirby and P. C. Williams, " The use of an electronic portal imaging device for exit dosimetry and quality control measurements.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 31, 593-603 (1995). 10.1016/0360-3016(94)00388-2
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.31 , pp. 593-603
    • Kirby, M.C.1    Williams, P.C.2
  • 14
    • 0030002611 scopus 로고    scopus 로고
    • The application of transit dosimetry to precision radiotherapy
    • DOI 10.1118/1.597719
    • V. N. Hansen, P. M. Evans, and W. Swindell, " The application of transit dosimetry to precision radiotherapy.," Med. Phys. 0094-2405 23 (5), 713-721 (1996). 10.1118/1.597719 (Pubitemid 26154437)
    • (1996) Medical Physics , vol.23 , Issue.5 , pp. 713-721
    • Hansen, V.N.1    Evans, P.M.2    Swindell, W.3
  • 15
    • 0029892227 scopus 로고    scopus 로고
    • Calculation of portal dose using the convolution/superposition method
    • DOI 10.1118/1.597810
    • T. R. McNutt, T. R. Mackie, P. Reckwerdt, N. Papanikolaou, and B. R. Paliwal, " Calculation of portal dose using the convolution/superposition method.," Med. Phys. 0094-2405 23, 527-535 (1996). 10.1118/1.597810 (Pubitemid 26120153)
    • (1996) Medical Physics , vol.23 , Issue.4 , pp. 527-535
    • McNutt, T.R.1    Mackie, T.R.2    Reckwerdt, P.3    Papanikolaou, N.4    Paliwal, B.R.5
  • 16
    • 0031045088 scopus 로고    scopus 로고
    • A convolution model to convert transmission dose images to exit dose distributions
    • DOI 10.1118/1.598066
    • R. Boellaard, M. Van Herk, and B. J. Mijnheer, " A convolution model to convert transmission dose images to exit dose distributions.," Med. Phys. 0094-2405 24 (2), 189-199 (1997). 10.1118/1.598066 (Pubitemid 27084024)
    • (1997) Medical Physics , vol.24 , Issue.2 , pp. 189-199
    • Boellaard, R.1    Van Herk, M.2    Mijnheer, B.J.3
  • 17
    • 0032784892 scopus 로고    scopus 로고
    • Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients
    • 0360-3016. 10.1016/S0360-3016(99)00328-4
    • K. L. Pasma, M. Kroonwijk, S. Quint, A. G. Visser, and B. J. M. Heijmen, " Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 45 (5), 1297-1303 (1999). 10.1016/S0360-3016(99)00328-4
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.45 , Issue.5 , pp. 1297-1303
    • Pasma, K.L.1    Kroonwijk, M.2    Quint, S.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 18
    • 0034176959 scopus 로고    scopus 로고
    • Relative profile and dose verification of intensity-modulated radiation therapy
    • DOI 10.1016/S0360-3016(99)00555-6, PII S0360301699005556
    • J. Chang, G. Mageras, C. S. Chui, C. C. L. Ling, and W. Lutz, " Relative profile and dose verification of intensity modulated radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 47 (1), 231-240 (2000). 10.1016/S0360-3016(99)00555-6 (Pubitemid 30179700)
    • (2000) International Journal of Radiation Oncology Biology Physics , vol.47 , Issue.1 , pp. 231-240
    • Chang, J.1    Mageras, G.S.2    Chui, C.S.3    Ling, C.C.4    Lutz, W.5
  • 20
    • 34047112709 scopus 로고    scopus 로고
    • Routine individualised patient dosimetry using electronic portal imaging devices
    • DOI 10.1016/j.radonc.2007.03.003, PII S0167814007000953
    • S. M. J. J. G. Nijsten, B. J. Minjheer, A. L. A. J. Dekker, P. Lambin, and A. W. H. Minken, " Routine individualised patient dosimetry using electronic portal imaging devices.," Radiother. Oncol. 0167-8140 83, 65-75 (2007). 10.1016/j.radonc.2007.03.003 (Pubitemid 46527950)
    • (2007) Radiotherapy and Oncology , vol.83 , Issue.1 , pp. 65-75
    • Nijsten, S.M.J.J.G.1    Mijnheer, B.J.2    Dekker, A.L.A.J.3    Lambin, P.4    Minken, A.W.H.5
  • 21
    • 33644999533 scopus 로고    scopus 로고
    • Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry
    • 0094-2405. 10.1118/1.2128498
    • P. B. Greer, " Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry.," Med. Phys. 0094-2405 32 (12), 3558-3568 (2005). 10.1118/1.2128498
    • (2005) Med. Phys. , vol.32 , Issue.12 , pp. 3558-3568
    • Greer, P.B.1
  • 22
    • 33644624754 scopus 로고    scopus 로고
    • Calibration of an amorphous-silicon flat panel portal imager for exit-beam dosimetry
    • DOI 10.1118/1.2168294
    • J. Chen, C. F. Chuang, O. Morin, M. Aubin, and J. Pouliot, " Calibration of an amorphous silicon flat panel portal imager for exit beam dosimetry.," Med. Phys. 0094-2405 33 (3), 584-594 (2006). 10.1118/1.2168294 (Pubitemid 43320162)
    • (2006) Medical Physics , vol.33 , Issue.3 , pp. 584-594
    • Chen, J.1    Chuang, C.F.2    Morin, O.3    Aubin, M.4    Pouliot, J.5
  • 23
    • 52049100092 scopus 로고    scopus 로고
    • A literature review of electronic portal imaging for radiotherapy dosimetry
    • 0167-8140,. 10.1016/j.radonc.2008.07.003
    • W. van Elmpt, L. McDermott, S. Nijsten, M. Wendling, P. Lambin, and B. Mijnheer, " A literature review of electronic portal imaging for radiotherapy dosimetry.," Radiother. Oncol. 0167-8140 88, 289-309 (2008). 10.1016/j.radonc.2008.07.003
    • (2008) Radiother. Oncol. , vol.88 , pp. 289-309
    • Van Elmpt, W.1    McDermott, L.2    Nijsten, S.3    Wendling, M.4    Lambin, P.5    Mijnheer, B.6
  • 24
    • 0037148114 scopus 로고    scopus 로고
    • Multilayer Gafchromic film detectors for breast skin dose determination in vivo
    • DOI 10.1088/0031-9155/47/2/401, PII S0031915502273248
    • L. E. Antonuk, " Electronic portal imaging devices: A review and historical perspective of contemporary technologies and research.," Phys. Med. Biol. 0031-9155 47, R31-R65 (2002). 10.1088/0031-9155/47/2/401 (Pubitemid 34110619)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.2
    • Cheung, T.1    Butson, M.J.2    Yu, P.K.N.3
  • 26
    • 0034977377 scopus 로고    scopus 로고
    • Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device
    • B. M. C. McCurdy, K. B. Luchka, and S. Pistorius, " Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device.," Med. Phys. 0094-2405 28, 911-924 (2001). 10.1118/1.1374244 (Pubitemid 32574675)
    • (2001) Medical Physics , vol.28 , Issue.6 , pp. 911-924
    • McCurdy, B.M.C.1    Luchka, K.2    Pistorius, S.3
  • 27
    • 0036797456 scopus 로고    scopus 로고
    • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry
    • DOI 10.1118/1.1508108
    • E. E. Grein, R. Lee, and K. Luchka, " An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.," Med. Phys. 0094-2405 29 (10), 2262-2268 (2002). 10.1118/1.1508108 (Pubitemid 35204434)
    • (2002) Medical Physics , vol.29 , Issue.10 , pp. 2262-2268
    • Grein, E.E.1    Lee, R.2    Luchka, K.3
  • 29
    • 14644388114 scopus 로고    scopus 로고
    • An Active Matrix Flat Panel Dosimeter (AMFPD) for in-phantom dosimetric measurements
    • DOI 10.1118/1.1855012
    • J. M. Moran, D. A. Roberts, T. S. Nurushev, and L. E. Antonuk, " An active matrix flat panel dosimeter (AMFPD) for in-phantom dosimetric measurements.," Med. Phys. 0094-2405 32 (2), 466-472 (2005). 10.1118/1.1855012 (Pubitemid 40322328)
    • (2005) Medical Physics , vol.32 , Issue.2 , pp. 466-472
    • Moran, J.M.1    Roberts, D.A.2    Nurushev, T.S.3    Antonuk, L.E.4    El-Mohri, Y.5    Fraass, B.A.6
  • 30
    • 0032808771 scopus 로고    scopus 로고
    • Relative dosimetry using active matrix flat-panel imager (AMFPI) technology
    • DOI 10.1118/1.598649
    • Y. El-Mohri, L. E. Antonuk, J. Yorkston, K. W. Jee, M. Maolinbay, K. L. Lam, and J. H. Siewerdsen, " Relative dosimetry using active matrix flat panel imager (AMFPI) technology.," Med. Phys. 0094-2405 26 (8), 1530-1541 (1999). 10.1118/1.598649 (Pubitemid 29402264)
    • (1999) Medical Physics , vol.26 , Issue.8 , pp. 1530-1541
    • El-Mohri, Y.1    Antonuk, L.E.2    Yorkston, J.3    Jee, K.-W.4    Maolinbay, M.5    Lam, K.L.6    Siewerdsen, J.H.7
  • 31
    • 52949139395 scopus 로고    scopus 로고
    • Initial evaluation of a commercial EPID modified to a novel direct-detection configuration for radiotherapy dosimetry
    • 0094-2405. 10.1118/1.2975156
    • P. Vial, P. B. Greer, L. Oliver, and C. Baldock, " Initial evaluation of a commercial EPID modified to a novel direct-detection configuration for radiotherapy dosimetry.," Med. Phys. 0094-2405 35 (10), 4362-4374 (2008). 10.1118/1.2975156
    • (2008) Med. Phys. , vol.35 , Issue.10 , pp. 4362-4374
    • Vial, P.1    Greer, P.B.2    Oliver, L.3    Baldock, C.4
  • 32
    • 36649008293 scopus 로고    scopus 로고
    • Performance of a direct-detection active matrix flat panel dosimeter (AMFPD) for IMRT measurements
    • DOI 10.1118/1.2805993
    • Y. Chen, J. M. Moran, D. A. Roberts, Y. El-Mohri, L. E. Antonuk, and B. A. Fraass, " Performance of a direct-detection active matrix flat panel dosimeter (AMFPD) for IMRT measurements.," Med. Phys. 0094-2405 34 (12), 4911-4922 (2007). 10.1118/1.2805993 (Pubitemid 350197726)
    • (2007) Medical Physics , vol.34 , Issue.12 , pp. 4911-4922
    • Chen, Y.1    Moran, J.M.2    Roberts, D.A.3    El-Mohri, Y.4    Antonuk, L.E.5    Fraass, B.A.6
  • 33
    • 0028013108 scopus 로고
    • X-ray scatter in megavoltage transmission radiography: Physical characteristics and influence on image quality
    • DOI 10.1118/1.597255
    • D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, " X-ray scatter in megavoltage transmission radiography: Physical characteristics and influence on image quality.," Med. Phys. 0094-2405 21 (1), 45-60 (1994). 10.1118/1.597255 (Pubitemid 24056495)
    • (1994) Medical Physics , vol.21 , Issue.1 , pp. 45-60
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4
  • 34
    • 44049113111 scopus 로고
    • Study and realization of an amorphous silicon x-ray detector with effective energy sensitivity
    • 0167-5087.
    • C. Manfredotti, F. Faccio, F. Fizzotti, and R. Marchisio, " Study and realization of an amorphous silicon x-ray detector with effective energy sensitivity.," Nucl. Instrum. Methods Phys. Res. 0167-5087 A322, 483-486 (1992).
    • (1992) Nucl. Instrum. Methods Phys. Res. , vol.322 , pp. 483-486
    • Manfredotti, C.1    Faccio, F.2    Fizzotti, F.3    Marchisio, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.