Volumn 38, Issue 5, 1999, Pages 591-596

Evaluation of an electronic portal imaging device for transit dosimetry

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CAMERA; DEVICE; DOSE RESPONSE; DOSIMETRY; ELECTRONICS; IMAGING; PRIORITY JOURNAL; RADIATION DOSE DISTRIBUTION;

EID: 0032816409     PISSN: 0284186X     EISSN: None     Source Type: Journal    
DOI: 10.1080/028418699431177     Document Type: Article
Times cited : (8)

References (15)
  • 1
    • 0027141513 scopus 로고
    • Measurement possibilities using an electronic portal imaging device
    • 1. Kirby MC, Williams PC. Measurement possibilities using an electronic portal imaging device. Radiother Oncol 1993; 29: 237-43.
    • (1993) Radiother Oncol , vol.29 , pp. 237-243
    • Kirby, M.C.1    Williams, P.C.2
  • 2
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • 2. Kirby MC, Williams PC. The use of an electronic portal imaging device for exit dosimetry and quality control measurements. Int J Radiat Oncol Biol Phys 1995; 31: 593-603.
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , pp. 593-603
    • Kirby, M.C.1    Williams, P.C.2
  • 3
    • 0029591732 scopus 로고
    • The accuracy of CT-based inhomogeneity corrections and in vivo dosimetry for the treatment of lung cancer
    • 3. Essers M, Lanson JW, Leunens G, Schnabel T, Mijnheer BJ. The accuracy of CT-based inhomogeneity corrections and in vivo dosimetry for the treatment of lung cancer. Radiother Oncol 1995; 37: 199-208.
    • (1995) Radiother Oncol , vol.37 , pp. 199-208
    • Essers, M.1    Lanson, J.W.2    Leunens, G.3    Schnabel, T.4    Mijnheer, B.J.5
  • 4
    • 0028196564 scopus 로고
    • Reliability of clinical port films for measuring dose inhomogeneities in radiotherapy for head and neck tumours
    • 4. Weltens C, Van Dam J, Leunens G, Dutreix A, van der Schueren E. Reliability of clinical port films for measuring dose inhomogeneities in radiotherapy for head and neck tumours. Radiother Oncol 1994; 30: 167-70.
    • (1994) Radiother Oncol , vol.30 , pp. 167-170
    • Weltens, C.1    Van Dam, J.2    Leunens, G.3    Dutreix, A.4    Van Der Schueren, E.5
  • 7
    • 0030002611 scopus 로고    scopus 로고
    • The application of transit dosimetry to precision radiotherapy
    • 7. Hansen VN, Evans PM, Swindell W. The application of transit dosimetry to precision radiotherapy. Med Phys 1996; 23: 713-21.
    • (1996) Med Phys , vol.23 , pp. 713-721
    • Hansen, V.N.1    Evans, P.M.2    Swindell, W.3
  • 8
    • 0030786466 scopus 로고    scopus 로고
    • Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model
    • 8. Boellaard R, van Herk M, Uiterwaal H, Mijnheer B. Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model. Radiother Oncol 1997; 44: 149-57.
    • (1997) Radiother Oncol , vol.44 , pp. 149-157
    • Boellaard, R.1    Van Herk, M.2    Uiterwaal, H.3    Mijnheer, B.4
  • 9
    • 0030047716 scopus 로고    scopus 로고
    • Scattered radiation in portal images: A Monte-Carlo simulation and a simple physical model
    • 9. Swindell W, Evans PM. Scattered radiation in portal images: a Monte-Carlo simulation and a simple physical model. Med Phys 1996; 23: 63-73.
    • (1996) Med Phys , vol.23 , pp. 63-73
    • Swindell, W.1    Evans, P.M.2
  • 11
    • 0028149975 scopus 로고
    • A technique of automatic compensator design for lung inhomogeneities correction using an electronic portal imaging device
    • 11. Yin FF, Schell MC, Rubin P. A technique of automatic compensator design for lung inhomogeneities correction using an electronic portal imaging device. Med Phys 1994; 21: 1729-32.
    • (1994) Med Phys , vol.21 , pp. 1729-1732
    • Yin, F.F.1    Schell, M.C.2    Rubin, P.3
  • 12
    • 0028803297 scopus 로고
    • Evaluation of electronic portal imaging device for missing tissue compensator design and verification
    • 12. Roback DM, Gerbi BJ. Evaluation of electronic portal imaging device for missing tissue compensator design and verification. Med Phys 1995; 22: 2029-34.
    • (1995) Med Phys , vol.22 , pp. 2029-2034
    • Roback, D.M.1    Gerbi, B.J.2
  • 13
    • 0009730792 scopus 로고
    • The physics of three-dimensional radiation therapy
    • 13. Webb S. The physics of three-dimensional radiation therapy. Med Sci Ser IOP 1993; 246-283.
    • (1993) Med Sci Ser IOP , pp. 246-283
    • Webb, S.1
  • 14
    • 0029585974 scopus 로고
    • Portal dose measurements in radiotherapy using an electronic portal imaging device (EPID)
    • 14. Heijmen BJM, Plasma KL, Kroonwijk M, et al. Portal dose measurements in radiotherapy using an electronic portal imaging device (EPID). Phys Med Biol 1995; 40: 1943-55.
    • (1995) Phys Med Biol , vol.40 , pp. 1943-1955
    • Heijmen, B.J.M.1    Plasma, K.L.2    Kroonwijk, M.3
  • 15
    • 0028825627 scopus 로고
    • Daily dosimetric quality control of the MM50 racetrack microtron using an electronic imaging device
    • 15. Dirkx M, Kroonwijk M, de Boer JC, Heijmen BJ. Daily dosimetric quality control of the MM50 Racetrack Microtron using an electronic imaging device. Radiother Oncol 1995; 37: 55-60.
    • (1995) Radiother Oncol , vol.37 , pp. 55-60
    • Dirkx, M.1    Kroonwijk, M.2    De Boer, J.C.3    Heijmen, B.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.