-
1
-
-
33846250457
-
Side effects of permanent I125 prostate seed implants in 667 patients treated in Leeds
-
DOI 10.1016/j.radonc.2006.11.006, PII S0167814006005974
-
D. Bottomley, D. Ash, B. Al-Qaisieh, B. Carey, J. Joseph, S. St Clair, and K. Gould, " Side effects of permanent I 125 prostate seed implants in 667 patients treated in Leeds.," Radiother. Oncol. 0167-8140 82, 46-49 (2007). 10.1016/j.radonc.2006.11.006 (Pubitemid 46097133)
-
(2007)
Radiotherapy and Oncology
, vol.82
, Issue.1
, pp. 46-49
-
-
Bottomley, D.1
Ash, D.2
Al-Qaisieh, B.3
Carey, B.4
Joseph, J.5
St Clair, S.6
Gould, K.7
-
2
-
-
0032982873
-
Intraoperative optimized inverse planning for prostate brachytherapy: Early experience
-
DOI 10.1016/S0360-3016(99)00088-7, PII S0360301699000887
-
E. M. Messing, J. B. Y. Zhang, D. J. Rubens, R. A. Brasacchio, J. G. Strang, A. Soni, M. C. Schell, P. G. Okunieff, and Y. Yu, " Intraoperative optimized inverse planning for prostate brachytherapy: Early experience.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 44, 801-808 (1999). 10.1016/S0360-3016(99)00088-7 (Pubitemid 29284128)
-
(1999)
International Journal of Radiation Oncology Biology Physics
, vol.44
, Issue.4
, pp. 801-808
-
-
Messing, E.M.1
Zhang, J.B.Y.2
Rubens, D.J.3
Brasacchio, R.A.4
Strang, J.G.5
Soni, A.6
Schell, M.C.7
Okunieff, P.G.8
Yu, Y.9
-
3
-
-
0037035357
-
103Pd prostate permanent seed implants - A bio-mathematical model
-
DOI 10.1088/0031-9155/47/7/313, PII S0031915502309990
-
N. Yue, Z. Chen, and R. Nath, " Edema-induced increase in tumour cell survival for I 125 and P 103 d prostate permanent seed implants-A bio-mathematical model.," Phys. Med. Biol. 0031-9155 47, 1185-1204 (2002). 10.1088/0031-9155/47/7/313 (Pubitemid 34413639)
-
(2002)
Physics in Medicine and Biology
, vol.47
, Issue.7
, pp. 1185-1204
-
-
Yue, N.1
Chen, Z.2
Nath, R.3
-
4
-
-
0028919251
-
Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
-
0094-2405,. 10.1118/1.597458
-
R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Megooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43.," Med. Phys. 0094-2405 22, 209-234 (1995). 10.1118/1.597458
-
(1995)
Med. Phys.
, vol.22
, pp. 209-234
-
-
Nath, R.1
Anderson, L.L.2
Luxton, G.3
Weaver, K.A.4
Williamson, J.F.5
Megooni, A.S.6
-
5
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
-
DOI 10.1118/1.1646040
-
M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. 0094-2405 31, 633-674 (2004). 10.1118/1.1646040 (Pubitemid 38381028)
-
(2004)
Medical Physics
, vol.31
, Issue.3
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
DeWerd, L.A.3
Hanson, W.F.4
Huq, M.S.5
Ibbott, G.S.6
Mitch, M.G.7
Nath, R.8
Williamson, J.F.9
-
6
-
-
59249090998
-
Monte Carlo radiation dose simulations and dosimetric comparison of the model 6711 and 9011 i 125 brachytherapy sources
-
0094-2405,. 10.1118/1.3056463
-
M. Rivard, " Monte Carlo radiation dose simulations and dosimetric comparison of the model 6711 and 9011 I 125 brachytherapy sources.," Med. Phys. 0094-2405 36, 486-491 (2009). 10.1118/1.3056463
-
(2009)
Med. Phys.
, vol.36
, pp. 486-491
-
-
Rivard, M.1
-
7
-
-
42949161466
-
60Co
-
DOI 10.1118/1.2898137
-
A. A. Nunn, S. D. Davis, J. A. Micka, and L. A. DeWerd, " LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x-ray spectra in the range of 20-250 kVp relative to C 60 o.," Med. Phys. 0094-2405 35, 1859-1869 (2008). 10.1118/1.2898137 (Pubitemid 351614800)
-
(2008)
Medical Physics
, vol.35
, Issue.5
, pp. 1859-1869
-
-
Nunn, A.A.1
Davis, S.D.2
Micka, J.A.3
DeWerd, L.A.4
-
8
-
-
0242409404
-
The response of LiF thermoluminescence dosimeters to photon beams in the energy range from 30 kV x rays to C 60 o gamma rays
-
0144-8420.
-
S. D. Davis, C. K. Ross, P. N. Mobit, L. Van der Zwan, W. J. Chase, and K. R. Shortt, " The response of LiF thermoluminescence dosimeters to photon beams in the energy range from 30 kV x rays to C 60 o gamma rays.," Radiat. Prot. Dosim. 0144-8420 106, 33-43 (2003).
-
(2003)
Radiat. Prot. Dosim.
, vol.106
, pp. 33-43
-
-
Davis, S.D.1
Ross, C.K.2
Mobit, P.N.3
Van Der Zwan, L.4
Chase, W.J.5
Shortt, K.R.6
-
9
-
-
33845310036
-
Monte Carlo and experimental dosimetry of an I125 brachytherapy seed
-
DOI 10.1118/1.2388158, 025612MPH
-
J. Dolan, Z. Li, and J. F. Williamson, " Monte Carlo and experimental dosimetry of an I 125 brachytherapy seed.," Med. Phys. 0094-2405 33, 4675-4684 (2006). 10.1118/1.2388158 (Pubitemid 44868105)
-
(2006)
Medical Physics
, vol.33
, Issue.12
, pp. 4675-4684
-
-
Dolan, J.1
Li, Z.2
Williamson, J.F.3
-
10
-
-
54949134922
-
An EGSnrc Monte Carlo-calculated database of TG-43 parameters
-
0094-2405,. 10.1118/1.2987676
-
R. E. P. Taylor and D. W. O. Rogers, " An EGSnrc Monte Carlo-calculated database of TG-43 parameters.," Med. Phys. 0094-2405 35, 4933-4944 (2008). 10.1118/1.2987676
-
(2008)
Med. Phys.
, vol.35
, pp. 4933-4944
-
-
Taylor, R.E.P.1
Rogers, D.W.O.2
-
11
-
-
0033862850
-
Experimental determination of the anisotropy function and anisotropy factor for model 6711 I-125 seeds
-
DOI 10.1118/1.1287285
-
R. S. Sloboda and G. V. Menon, " Experimental determination of the anisotropy function and anisotropy factor for model 6711 I-125 seeds.," Med. Phys. 0094-2405 27, 1789-1799 (2000). 10.1118/1.1287285 (Pubitemid 30666354)
-
(2000)
Medical Physics
, vol.27
, Issue.8
, pp. 1789-1799
-
-
Sloboda, R.S.1
Menon, G.V.2
-
12
-
-
0033625386
-
Dosimetric characteristics of the InterSource palladium brachytherapy source
-
DOI 10.1118/1.598991
-
A. S. Meigooni, K. Sowards, and M. Soldano, " Dosimetric characteristics of the InterSource P 103 d brachytherapy source.," Med. Phys. 0094-2405 27, 1093-1100 (2000). 10.1118/1.598991 (Pubitemid 30350020)
-
(2000)
Medical Physics
, vol.27
, Issue.5
, pp. 1093-1100
-
-
Meigooni, A.S.1
Sowards, K.2
Soldano, M.3
-
13
-
-
0023717249
-
A comparison of solid phantoms with water for dosimetry of i 125 brachytherapy sources
-
0094-2405,. 10.1118/1.596182
-
A. S. Meigooni, J. A. Meli, and R. Nath, " A comparison of solid phantoms with water for dosimetry of I 125 brachytherapy sources.," Med. Phys. 0094-2405 15, 695-701 (1988). 10.1118/1.596182
-
(1988)
Med. Phys.
, vol.15
, pp. 695-701
-
-
Meigooni, A.S.1
Meli, J.A.2
Nath, R.3
-
14
-
-
33750570047
-
103Pd brachytherapy sources
-
DOI 10.1118/1.2357018
-
A. Meigooni, S. Awan, N. Thompson, and S. Dini, " Updated Solid Water to water conversion factors for I 125 and P 103 d brachytherapy sources.," Med. Phys. 0094-2405 33, 3988-3992 (2006). 10.1118/1.2357018 (Pubitemid 44673089)
-
(2006)
Medical Physics
, vol.33
, Issue.11
, pp. 3988-3992
-
-
Meigooni, A.S.1
Awan, S.B.2
Thompson, N.S.3
Dini, S.A.4
-
15
-
-
0035543812
-
103Pd brachytherapy source
-
DOI 10.1118/1.1414007
-
A. S. Meigooni, Z. Bharucha, M. Yoe-Sein, and K. Sowards, " Dosimetric characteristics of the Best double-wall P 103 d brachytherapy source.," Med. Phys. 0094-2405 28, 2568-2575 (2001). 10.1118/1.1414007 (Pubitemid 34031545)
-
(2001)
Medical Physics
, vol.28
, Issue.12
, pp. 2568-2575
-
-
Meigooni, A.S.1
Bharucha, Z.2
Yoe-Sein, M.3
Sowards, K.4
-
16
-
-
0035999398
-
125I interstitial brachytherapy seed
-
DOI 10.1118/1.1469631
-
G. Anagnostopoulos, D. Baltas, P. Karaiskos, P. Sandilos, P. Papagiannis, and L. Sakelliou, " Thermoluminescent dosimetry of the selectSeed I 125 interstitial brachytherapy seed.," Med. Phys. 0094-2405 29, 709-716 (2002). 10.1118/1.1469631 (Pubitemid 34525899)
-
(2002)
Medical Physics
, vol.29
, Issue.5
, pp. 709-716
-
-
Anagnostopoulos, G.1
Baltas, D.2
Karaiskos, P.3
Sandilos, P.4
Papagiannis, P.5
Sakelliou, L.6
-
17
-
-
3142677842
-
Phantom size in brachytherapy source dosimetric studies
-
DOI 10.1118/1.1759826
-
J. Ṕrez-Calatayud, D. Granero, and F. Ballester, " Phantom size in brachytherapy source dosimetric studies.," Med. Phys. 0094-2405 31, 2075-2081 (2004). 10.1118/1.1759826 (Pubitemid 38924828)
-
(2004)
Medical Physics
, vol.31
, Issue.7
, pp. 2075-2081
-
-
Perez-Calatayud, J.1
Granero, D.2
Ballester, F.3
-
18
-
-
0016915519
-
The reusability of solid thermoluminescent dosimeters and its relation to the maintenance of TL standards
-
0017-9078,. 10.1097/00004032-197601000-00015
-
F. M. Cox, A. C. Lucas, and B. M. Kaspar, " The reusability of solid thermoluminescent dosimeters and its relation to the maintenance of TL standards.," Health Phys. 0017-9078 30, 135-137 (1976). 10.1097/00004032-197601000-00015
-
(1976)
Health Phys.
, vol.30
, pp. 135-137
-
-
Cox, F.M.1
Lucas, A.C.2
Kaspar, B.M.3
-
19
-
-
0015679343
-
Effect of plastic deformation on the thermoluminescence of LiF(TLD-100) single crystals
-
0022-3727,. 10.1088/0022-3727/6/17/322
-
M. Srinivasan and L. DeWerd, " Effect of plastic deformation on the thermoluminescence of LiF(TLD-100) single crystals.," J. Phys. D: Appl. Phys. 0022-3727 6, 2142-2149 (1973). 10.1088/0022-3727/6/17/322
-
(1973)
J. Phys. D: Appl. Phys.
, vol.6
, pp. 2142-2149
-
-
Srinivasan, M.1
Dewerd, L.2
-
20
-
-
4444315278
-
The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P
-
DOI 10.1093/rpd/nch310
-
Y. Horowitz and P. Olko, " The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P.," Radiat. Prot. Dosim. 0144-8420 109, 331-348 (2004). 10.1093/rpd/nch310 (Pubitemid 39162563)
-
(2004)
Radiation Protection Dosimetry
, vol.109
, Issue.4
, pp. 331-348
-
-
Horowitz, Y.1
Olko, P.2
-
21
-
-
0038710315
-
125I seed
-
DOI 10.1118/1.1577251
-
S. Chiu-Tsao, T. Duckworth, C. Hsiung, Z. Li, J. Williamson, N. Patel, and L. Harrison, " Thermoluminescent dosimetry of the SourceTech Medical model STM1251 I 125 seed.," Med. Phys. 0094-2405 30, 1732-1735 (2003). 10.1118/1.1577251 (Pubitemid 36885790)
-
(2003)
Medical Physics
, vol.30
, Issue.7
, pp. 1732-1735
-
-
Chiu-Tsao, S.-T.1
Duckworth, T.L.2
Hsiung, C.-Y.3
Li, Z.4
Williamson, J.5
Patel, N.S.6
Harrison, L.B.7
-
25
-
-
0028891525
-
Dose distributions and dose rate constants for new ytterbium-169 brachytherapy seeds
-
0094-2405,. 10.1118/1.597597
-
M. S. MacPherson and J. J. Battista, " Dose distributions and dose rate constants for new ytterbium-169 brachytherapy seeds.," Med. Phys. 0094-2405 22, 89-96 (1995). 10.1118/1.597597
-
(1995)
Med. Phys.
, vol.22
, pp. 89-96
-
-
MacPherson, M.S.1
Battista, J.J.2
-
26
-
-
0034857269
-
125I model I25.S06 interstitial brachytherapy seed
-
DOI 10.1118/1.1388218
-
N. S. Patel, S. -T. Chiu-Tsao, J. F. Williamson, P. Fan, T. Duckworth, D. Shasha, and L. B. Harrison, " Thermoluminescent dosimetry of the Symmetra I 125 model I25.S06 interstitial brachytherapy seed.," Med. Phys. 0094-2405 28, 1761-1769 (2001). 10.1118/1.1388218 (Pubitemid 32783221)
-
(2001)
Medical Physics
, vol.28
, Issue.8
, pp. 1761-1769
-
-
Patel, N.S.1
Chiu-Tsao, S.-T.2
Williamson, J.F.3
Fan, P.4
Duckworth, T.5
Shasha, D.6
Harrison, L.B.7
-
27
-
-
4344685337
-
An evaluation of the AAPM-TG43 dosimetry protocol for I-125 brachytherapy seed
-
DOI 10.1088/0031-9155/49/14/010, PII S0031915504728237
-
P. Mobit and I. Badragan, " Response of LiF-TLD micro-rods around I 125 radioactive seed.," Phys. Med. Biol. 0031-9155 49, 3161-3170 (2004). 10.1088/0031-9155/49/14/010 (Pubitemid 39140004)
-
(2004)
Physics in Medicine and Biology
, vol.49
, Issue.14
, pp. 3161-3170
-
-
Mobit, P.1
Badragan, I.2
-
28
-
-
28044456522
-
125I interstitial brachytherapy seed
-
DOI 10.1118/1.2089588
-
G. Lymperopoulou, P. Papagiannis, L. Sakelliou, P. Karaiskos, P. Sandilos, A. Przykutta, and D. Baltas, " Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I25.S17 I 125 interstitial brachytherapy seed.," Med. Phys. 0094-2405 32, 3313-3317 (2005). 10.1118/1.2089588 (Pubitemid 41689281)
-
(2005)
Medical Physics
, vol.32
, Issue.11
, pp. 3313-3317
-
-
Lymperopoulou, G.1
Papagiannis, P.2
Sakelliou, L.3
Karaiskos, P.4
Sandilos, P.5
Przykutta, A.6
Baltas, D.7
-
29
-
-
77950571425
-
Response of LiF:Mg,Ti thermoluminescent dosimeters to low-energy photons
-
0094-2405,. 10.1118/1.2962044
-
B. E. Rasmussen, S. D. Davis, J. A. Micka, and L. A. DeWerd, " Response of LiF:Mg,Ti thermoluminescent dosimeters to low-energy photons.," Med. Phys. 0094-2405 35, 2792-2792 (2008). 10.1118/1.2962044
-
(2008)
Med. Phys.
, vol.35
, pp. 2792-2792
-
-
Rasmussen, B.E.1
Davis, S.D.2
Micka, J.A.3
Dewerd, L.A.4
-
30
-
-
4544341067
-
-
X-5 Monte Carlo Team, "," Los Alamos National Laboratory Report No. LA-UR-03-1987, Los Alamos, NM.
-
X-5 Monte Carlo Team, " MCNP-A general Monte Carlo N-particle transport code, Version 5.," Los Alamos National Laboratory Report No. LA-UR-03-1987, Los Alamos, NM, 2005.
-
(2005)
MCNP-A General Monte Carlo N-particle Transport Code, Version 5
-
-
-
31
-
-
14344258392
-
-
LA-UR-03-1019, Los Alamos National Laboratory, Los Alamos, NM.
-
M. C. White, " Photoatomic data library MCPLIB04: A new photoatomic library based on data from ENDF/B-VI release 8.," LA-UR-03-1019, Los Alamos National Laboratory, Los Alamos, NM, 2003.
-
(2003)
Photoatomic Data Library MCPLIB04: A New Photoatomic Library Based on Data from ENDF/B-VI Release 8
-
-
White, M.C.1
-
32
-
-
33744798255
-
169Yb sources
-
DOI 10.1118/1.2199987
-
C. S. Melhus and M. J. Rivard, " Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for C 137 s, I 125, I 192 r, P 103 d, and Y 169 b sources.," Med. Phys. 0094-2405 33, 1729-1737 (2006). 10.1118/1.2199987 (Pubitemid 43830261)
-
(2006)
Medical Physics
, vol.33
, Issue.6
, pp. 1729-1737
-
-
Melhus, C.S.1
Rivard, M.J.2
-
33
-
-
1642363889
-
New national air-kerma-strength standards for i 125 and P 103 d brachytherapy seeds
-
1044-677X.
-
S. M. Seltzer, P. J. Lamperti, R. Loevinger, M. G. Mitch, J. T. Weaver, and B. M. Coursey, " New national air-kerma-strength standards for I 125 and P 103 d brachytherapy seeds.," J. Res. Natl. Inst. Stand. Technol. 1044-677X 108, 337-357 (2003).
-
(2003)
J. Res. Natl. Inst. Stand. Technol.
, vol.108
, pp. 337-357
-
-
Seltzer, S.M.1
Lamperti, P.J.2
Loevinger, R.3
Mitch, M.G.4
Weaver, J.T.5
Coursey, B.M.6
-
36
-
-
0032717811
-
Monte Carlo simulation of a typical Co-60 therapy source
-
0094-2405,. 10.1118/1.598770
-
G. M. Mora, A. Maio, and D. W. O. Rogers, " Monte Carlo simulation of a typical Co-60 therapy source.," Med. Phys. 0094-2405 26, 2494-2502 (1999). 10.1118/1.598770
-
(1999)
Med. Phys.
, vol.26
, pp. 2494-2502
-
-
Mora, G.M.1
Maio, A.2
Rogers, D.W.O.3
-
37
-
-
77950580648
-
Characterization of thermoluminescent dosimeter reader precision and artifacts
-
0094-2405,. 10.1118/1.2962059
-
L. Bartol and L. DeWerd, " Characterization of thermoluminescent dosimeter reader precision and artifacts.," Med. Phys. 0094-2405 35, 2796-2796 (2008). 10.1118/1.2962059
-
(2008)
Med. Phys.
, vol.35
, pp. 2796-2796
-
-
Bartol, L.1
Dewerd, L.2
-
38
-
-
77950550073
-
-
personal communication (4 June).
-
M. J. Rivard, personal communication (4 June 2009).
-
(2009)
-
-
Rivard, M.J.1
-
39
-
-
34147127408
-
Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources
-
DOI 10.1118/1.2713217
-
Z. J. Chen and R. Nath, " Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources.," Med. Phys. 0094-2405 34, 1412-1430 (2007). 10.1118/1.2713217 (Pubitemid 46555772)
-
(2007)
Medical Physics
, vol.34
, Issue.4
, pp. 1412-1430
-
-
Chen, Z.J.1
Nath, R.2
-
40
-
-
0034004934
-
103Pd interstitial brachytherapy source
-
DOI 10.1118/1.598924
-
J. F. Williamson, " Monte Carlo modeling of the transverse-axis dose distribution of the Model 200 P 103 d interstitial brachytherapy source.," Med. Phys. 0094-2405 27, 643-654 (2000). 10.1118/1.598924 (Pubitemid 30227039)
-
(2000)
Medical Physics
, vol.27
, Issue.4
, pp. 643-654
-
-
Williamson, J.F.1
|