메뉴 건너뛰기




Volumn 25, Issue 1, 2009, Pages 358-361

Initial application of a geometric QA tool for integrated MV and kV imaging systems on Trilogy, Synergy, and Vero

Author keywords

Geometric calibration; Image guidance; kV imaging; MV imaging; QA

Indexed keywords

BIOMEDICAL ENGINEERING; COMPUTERIZED TOMOGRAPHY; GEOMETRY; IMAGING SYSTEMS; LINEAR ACCELERATORS; MEDICAL PHYSICS; ONCOLOGY; PHANTOMS; RADIOTHERAPY; RIGID STRUCTURES; X RAY TUBES; X RAYS;

EID: 77950381177     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03474-9_101     Document Type: Conference Paper
Times cited : (4)

References (9)
  • 1
    • 33746843175 scopus 로고    scopus 로고
    • Development of a four-dimensional image-guided radiotherapy system with a gimbaled x-ray head
    • KaminoY, Takayama K, Kokubo M, et al. (2006) Development of a four-dimensional image-guided radiotherapy system with a gimbaled x-ray head. Int. J. Radi. Onco. Biol. Phys. 66, 271-278
    • (2006) Int. J. Radi. Onco. Biol. Phys. , vol.66 , pp. 271-278
    • Kamino, Y.1    Takayama, K.2    Kokubo, M.3
  • 2
    • 31044444873 scopus 로고    scopus 로고
    • The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator
    • M. B. Sharpe, D. J. Moseley, T. G. Purdie, et al (2006) The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator. Med. Phys. 33: 136-144
    • (2006) Med. Phys. , vol.33 , pp. 136-144
    • Sharpe, M.B.1    Moseley, D.J.2    Purdie, T.G.3
  • 3
    • 17844380035 scopus 로고    scopus 로고
    • Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    • Y. Cho, D. J. Moseley, J. H. Siewerdsen, et al (2005) Accurate technique for complete geometric calibration of cone-beam computed tomography systems. Med. Phys. 32: 968-983
    • (2005) Med. Phys. , vol.32 , pp. 968-983
    • Cho, Y.1    Moseley, D.J.2    Siewerdsen, J.H.3
  • 4
    • 0027637986 scopus 로고
    • Geometrical calibration of x-ray imaging chains for three-dimensional reconstruction
    • A. Rougee, C. Picard, C. Ponchut, et al (1993) Geometrical calibration of x-ray imaging chains for three-dimensional reconstruction. Comput. Med. Imaging Graph. 17: 295-300
    • (1993) Comput. Med. Imaging Graph. , vol.17 , pp. 295-300
    • Rougee, A.1    Picard, C.2    Ponchut, C.3
  • 5
    • 0033954113 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities
    • R. Fahrig and D. W. Holdsworth (2000) Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities. Med. Phys. 27: 30-38
    • (2000) Med. Phys. , vol.27 , pp. 30-38
    • Fahrig, R.1    Holdsworth, D.W.2
  • 6
    • 33750568952 scopus 로고    scopus 로고
    • A quality assurance program for the on-board imagers
    • S. Yoo, G. Y. Kim, R. Hammoud, et al (2006) A quality assurance program for the on-board imagers. Med. Phys. 33: 4431-4447.
    • (2006) Med. Phys. , vol.33 , pp. 4431-4447
    • Yoo, S.1    Kim, G.Y.2    Hammoud, R.3
  • 7
    • 33744794934 scopus 로고    scopus 로고
    • A geometric calibration method for cone beam CT systems
    • K. Yang, A. L. Kwan, D. F. Miller, et al (2006) A geometric calibration method for cone beam CT systems. Med. Phys. 33: 1695-1706.
    • (2006) Med. Phys. , vol.33 , pp. 1695-1706
    • Yang, K.1    Kwan, A.L.2    Miller, D.F.3
  • 8
    • 51849109810 scopus 로고    scopus 로고
    • Linac mechanic QA using a cylindrical phantom
    • M. Mamalui-Hunter, H. Li, and D. A. Low (2008) Linac mechanic QA using a cylindrical phantom. Phys. Med. Biol. 53: 5139-5149
    • (2008) Phys. Med. Biol. , vol.53 , pp. 5139-5149
    • Mamalui-Hunter, M.1    Li, H.2    Low, D.A.3
  • 9
    • 41449117460 scopus 로고    scopus 로고
    • Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems
    • Mao W., Lee L, and Xing L. (2008) Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems. Med. Phys. 35: 1497-1506
    • (2008) Med. Phys. , vol.35 , pp. 1497-1506
    • Mao, W.1    Lee, L.2    Xing, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.