메뉴 건너뛰기




Volumn 27, Issue 1, 2010, Pages 9-13

Use of a novel needle wire in patients undergoing transseptal puncture associated with severe septal tenting

Author keywords

Atrial fibrillation; Catheter ablation; Fossa ovalis; Septal tenting; Transseptal puncture

Indexed keywords

ADULT; ARTICLE; CATHETER ABLATION; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; EQUIPMENT DESIGN; FEMALE; GUIDE WIRE; HEART ANEURYSM; HEART ATRIUM SEPTUM; HEART CATHETERIZATION; HIGH RISK PATIENT; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PATIENT SAFETY; PRIORITY JOURNAL; PULMONARY VEIN; REPEAT PROCEDURE; SUPRAVENTRICULAR TACHYCARDIA; SURGICAL TECHNIQUE;

EID: 77950371622     PISSN: 1383875X     EISSN: 15728595     Source Type: Journal    
DOI: 10.1007/s10840-009-9460-1     Document Type: Article
Times cited : (15)

References (14)
  • 1
    • 0000556337 scopus 로고
    • Transseptal left atrial puncture; New technique for the measurement of left atrial pressure in man
    • 10.1016/0002-9149(59)90347-9 13649591
    • J Ross Jr E Braunwald AG Morrow 1959 Transseptal left atrial puncture; new technique for the measurement of left atrial pressure in man American Journal of Cardiology 3 653 655 10.1016/0002-9149(59)90347-9 13649591
    • (1959) American Journal of Cardiology , vol.3 , pp. 653-655
    • Ross Jr, J.1    Braunwald, E.2    Morrow, A.G.3
  • 2
    • 0034649299 scopus 로고    scopus 로고
    • Electrophysiological breakthroughs from the left atrium to the pulmonary veins
    • 1:STN:280:DC%2BD3M%2FktFCltg%3D%3D 11076817
    • M Haissaguerre DC Shah P Jais M Hocini T Yamane I Deisenhofer, et al. 2000 Electrophysiological breakthroughs from the left atrium to the pulmonary veins Circulation 102 2463 2465 1:STN:280:DC%2BD3M%2FktFCltg%3D%3D 11076817
    • (2000) Circulation , vol.102 , pp. 2463-2465
    • Haissaguerre, M.1    Shah, D.C.2    Jais, P.3    Hocini, M.4    Yamane, T.5    Deisenhofer, I.6
  • 3
    • 20144363969 scopus 로고    scopus 로고
    • Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation
    • DOI 10.1161/01.CIR.0000157153.30978.67
    • R Cappato H Calkins SA Chen W Davies Y Iesaka J Kalman, et al. 2005 Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation Circulation 111 1100 1105 10.1161/01.CIR.0000157153. 30978.67 15723973 (Pubitemid 40365469)
    • (2005) Circulation , vol.111 , Issue.9 , pp. 1100-1105
    • Cappato, R.1    Calkins, H.2    Chen, S.-A.3    Davies, W.4    Iesaka, Y.5    Kalman, J.6    Kim, Y.-H.7    Klein, G.8    Packer, D.9    Skanes, A.10
  • 7
    • 56149123640 scopus 로고    scopus 로고
    • Interatrial septum thickness and difficulty with transseptal puncture during redo catheter ablation of atrial fibrillation
    • 10.1111/j.1540-8159.2008.01233.x 19067814
    • DR Tomlinson N Sabharwal Y Bashir TR Betts 2008 Interatrial septum thickness and difficulty with transseptal puncture during redo catheter ablation of atrial fibrillation Pacing and Clinical Electrophysiology 31 1606 1611 10.1111/j.1540-8159.2008.01233.x 19067814
    • (2008) Pacing and Clinical Electrophysiology , vol.31 , pp. 1606-1611
    • Tomlinson, D.R.1    Sabharwal, N.2    Bashir, Y.3    Betts, T.R.4
  • 8
    • 44649157124 scopus 로고    scopus 로고
    • The change in the fluoroscopy-guided transseptal puncture site and difficult punctures in catheter ablation of recurrent atrial fibrillation
    • 10.1093/europace/eun013 18245772
    • YF Hu CT Tai YJ Lin SL Chang LW Lo W Wongcharoen, et al. 2008 The change in the fluoroscopy-guided transseptal puncture site and difficult punctures in catheter ablation of recurrent atrial fibrillation Europace 10 276 279 10.1093/europace/eun013 18245772
    • (2008) Europace , vol.10 , pp. 276-279
    • Hu, Y.F.1    Tai, C.T.2    Lin, Y.J.3    Chang, S.L.4    Lo, L.W.5    Wongcharoen, W.6
  • 9
    • 36749030018 scopus 로고    scopus 로고
    • Radiofrequency current delivery via transseptal needle to facilitate septal puncture
    • DOI 10.1016/j.hrthm.2007.07.008, PII S1547527107007126
    • C Bidart M Vaseghi DA Cesario A Mahajan O Fujimura NG Boyle, et al. 2007 Radiofrequency current delivery via transseptal needle to facilitate septal puncture Heart Rhythm 4 1573 1576 10.1016/j.hrthm.2007.07.008 17997362 (Pubitemid 350199249)
    • (2007) Heart Rhythm , vol.4 , Issue.12 , pp. 1573-1576
    • Bidart, C.1    Vaseghi, M.2    Cesario, D.A.3    Mahajan, A.4    Fujimura, O.5    Boyle, N.G.6    Shivkumar, K.7
  • 10
    • 41849150393 scopus 로고    scopus 로고
    • Fossa ovalis radiofrequency perforation in a difficult case of conventional transseptal puncture for atrial fibrillation ablation
    • 10.1007/s10840-007-9194-x 18274714
    • M Casella RA Dello G Pelargonio A Martino S De Paulis P Zecchi, et al. 2008 Fossa ovalis radiofrequency perforation in a difficult case of conventional transseptal puncture for atrial fibrillation ablation Journal of Interventional Cardiac Electrophysiology 21 249 253 10.1007/s10840-007-9194-x 18274714
    • (2008) Journal of Interventional Cardiac Electrophysiology , vol.21 , pp. 249-253
    • Casella, M.1    Dello, R.A.2    Pelargonio, G.3    Martino, A.4    De Paulis, S.5    Zecchi, P.6
  • 11
    • 14644404934 scopus 로고    scopus 로고
    • Transcatheter creation of atrial septal perforation using a radiofrequency transseptal system: Novel approach as an alternative to transseptal needle puncture
    • DOI 10.1002/ccd.20284
    • Y Sakata T Feldman 2005 Transcatheter creation of atrial septal perforation using a radiofrequency transseptal system: novel approach as an alternative to transseptal needle puncture Catheter Cardiovasc Interv 64 327 332 10.1002/ccd.20284 15736263 (Pubitemid 40322043)
    • (2005) Catheterization and Cardiovascular Interventions , vol.64 , Issue.3 , pp. 327-332
    • Sakata, Y.1    Feldman, T.2
  • 12
    • 33847660528 scopus 로고    scopus 로고
    • Transseptal puncture: Use of an angioplasty guidewire for enhanced safety
    • DOI 10.1002/ccd.20987
    • D Hildick-Smith J McCready J de Giovanni 2007 Transseptal puncture: use of an angioplasty guidewire for enhanced safety Catheterization and Cardiovascular Interventions 69 519 521 10.1002/ccd.20987 17286295 (Pubitemid 46363852)
    • (2007) Catheterization and Cardiovascular Interventions , vol.69 , Issue.4 , pp. 519-521
    • Hildick-Smith, D.1    McCready, J.2    De Giovanni, J.3
  • 13
    • 27244445484 scopus 로고    scopus 로고
    • Shifting of puncture site in the fossa ovalis during radiofrequency catheter ablation: Intracardiac echocardiography-guided transseptal left heart catheterization
    • DOI 10.1536/jhj.44.673
    • T Hanaoka K Suyama A Taguchi W Shimizu T Kurita N Aihara, et al. 2003 Shifting of puncture site in the fossa ovalis during radiofrequency catheter ablation: intracardiac echocardiography-guided transseptal left heart catheterization Japanese Heart Journal 44 673 680 10.1536/jhj.44.673 14587649 (Pubitemid 41518968)
    • (2003) Japanese Heart Journal , vol.44 , Issue.5 , pp. 673-680
    • Hanaoka, T.1    Suyama, K.2    Taguchi, A.3    Shimizu, W.4    Kurita, T.5    Aihara, N.6    Kamakura, S.7
  • 14
    • 59649119003 scopus 로고    scopus 로고
    • Intracardiac echocardiography during catheter ablation of atrial fibrillation
    • 10.1093/europace/eun233 18955398
    • W Saliba J Thomas 2008 Intracardiac echocardiography during catheter ablation of atrial fibrillation Europace 10 Suppl 3 iii42 iii47 10.1093/europace/eun233 18955398
    • (2008) Europace , vol.10 , Issue.SUPPL 3
    • Saliba, W.1    Thomas, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.