메뉴 건너뛰기




Volumn 21, Issue 3, 2010, Pages 279-282

Discard tubes are not necessary when drawing samples for specialized coagulation testing

Author keywords

Coagulation testing; Discard tube; Factor assays; Pilot tube; Preanalytical variables

Indexed keywords

BLOOD CLOTTING FACTOR 10; BLOOD CLOTTING FACTOR 11; BLOOD CLOTTING FACTOR 7; BLOOD CLOTTING FACTOR 8; BLOOD CLOTTING FACTOR 9; CITRIC ACID; D DIMER; FIBRINOGEN; PROTEIN C; PROTEIN S; PROTHROMBIN; WARFARIN;

EID: 77950282209     PISSN: 09575235     EISSN: None     Source Type: Journal    
DOI: 10.1097/MBC.0b013e3283380d12     Document Type: Article
Times cited : (24)

References (12)
  • 4
    • 0037412986 scopus 로고    scopus 로고
    • Effect of drawing a discard tube on PT and aPTT results in healthy adults
    • Bamberg R, Cottle JN, Williams JC. Effect of drawing a discard tube on PT and aPTT results in healthy adults. Clin Lab Sci 2003; 16:16-19.
    • (2003) Clin Lab Sci , vol.16 , pp. 16-19
    • Bamberg, R.1    Cottle, J.N.2    Williams, J.C.3
  • 5
    • 0030793727 scopus 로고    scopus 로고
    • Prothrombin time determination. The lack of need for a discard tube and 24-h stability
    • Brigden ML, Graydon C, McLeod B, Lesperance M. Prothrombin time determination. The lack of need for a discard tube and 24-h stability. Am J Clin Pathol 1997; 108:422-426.
    • (1997) Am J Clin Pathol , vol.108 , pp. 422-426
    • Brigden, M.L.1    Graydon, C.2    McLeod, B.3    Lesperance, M.4
  • 6
    • 0031006634 scopus 로고    scopus 로고
    • Prothrombin time and activated partial thromboplastin time can be performed on the first tube
    • Gottfried EL, Adachi MM. Prothrombin time and activated partial thromboplastin time can be performed on the first tube. Am J Clin Pathol 1997; 107:681-683.
    • (1997) Am J Clin Pathol , vol.107 , pp. 681-683
    • Gottfried, E.L.1    Adachi, M.M.2
  • 7
    • 0029950231 scopus 로고    scopus 로고
    • Prothrombin time: One tube or two
    • Yawn BP, Loge C, Dale J. Prothrombin time: one tube or two. Am J Clin Pathol 1996; 105:794-797.
    • (1996) Am J Clin Pathol , vol.105 , pp. 794-797
    • Yawn, B.P.1    Loge, C.2    Dale, J.3
  • 8
    • 36649038572 scopus 로고    scopus 로고
    • Effect of tube filling order on specific coagulation parameters in healthy subjects
    • Serin E, Bugdayci G. Effect of tube filling order on specific coagulation parameters in healthy subjects. Lab Med 2007; 38:556-558.
    • (2007) Lab Med , vol.38 , pp. 556-558
    • Serin, E.1    Bugdayci, G.2
  • 9
    • 7044239520 scopus 로고    scopus 로고
    • Effect of specimen collection on routine coagulation assays and d-dimer measurement
    • Lippi G, Guidi GC. Effect of specimen collection on routine coagulation assays and d-dimer measurement. Clin Chem 2004; 50:2150-2152.
    • (2004) Clin Chem , vol.50 , pp. 2150-2152
    • Lippi, G.1    Guidi, G.C.2
  • 11
    • 0030857330 scopus 로고    scopus 로고
    • Are discard tubes necessary in coagulation studies?
    • Adcock DM, Kressin DC, Marlar RA. Are discard tubes necessary in coagulation studies? Lab Med 1997; 28:530-533.
    • (1997) Lab Med , vol.28 , pp. 530-533
    • Adcock, D.M.1    Kressin, D.C.2    Marlar, R.A.3
  • 12
    • 84877103568 scopus 로고    scopus 로고
    • Determination of factor coagulant activities; Approved guideline
    • NCCLS. Wayne, Pennsylvania: Clinical and Laboratory Standards Institute
    • NCCLS. Determination of factor coagulant activities; approved guideline. NCCLS Document H48-A. Wayne, Pennsylvania: Clinical and Laboratory Standards Institute; 1997.
    • (1997) NCCLS Document


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.