메뉴 건너뛰기




Volumn 49, Issue 7, 2010, Pages 3162-3168

Magnetic bistability in a cobalt bis(dioxolene) complex: Long-lived photoinduced valence tautomerism

Author keywords

[No Author keywords available]

Indexed keywords


EID: 77950273381     PISSN: 00201669     EISSN: None     Source Type: Journal    
DOI: 10.1021/ic901998p     Document Type: Article
Times cited : (41)

References (39)
  • 11
    • 84966989667 scopus 로고    scopus 로고
    • Valence tautomerism in dioxolene complexes of cobalt
    • Miller, J. S., Drillon, M., Eds.; Wiley-VCH: New York
    • Shultz, D. A. Valence Tautomerism in Dioxolene Complexes of Cobalt In Magnetism: Molecules to Materials II; Miller, J. S., Drillon, M., Eds.; Wiley-VCH: New York, 2001; Vol. 2, pp 281-306.
    • (2001) Magnetism: Molecules to Materials II , vol.2 , pp. 281-306
    • Shultz, D.A.1
  • 24
    • 0004236045 scopus 로고
    • VCH Publishers, Inc.: New York
    • Kahn, O. Molecular Magnetism; VCH Publishers, Inc.: New York, 1993; p 380.
    • (1993) Molecular Magnetism , pp. 380
    • Kahn, O.1
  • 25
    • 77950259035 scopus 로고    scopus 로고
    • Heating and Cooling rates: 10 K-100 K range, 3 K/min; 105 K-120 K range, 2 K/min; 130 K-300 K range, 5 K/min.
    • Heating and Cooling rates: 10 K-100 K range, 3 K/min; 105 K-120 K range, 2 K/min; 130 K-300 K range, 5 K/min.
  • 26
    • 77950272394 scopus 로고    scopus 로고
    • Scan 1 - Heating rates: 10 K-100 K range, 1 K/min; 105 K-120 K range, 2 K/min; 130 K-300 K range, 5 K/min, Cooling rates: 10 K-100 K range, 3 K/min; 105 K-120 K range, 2 K/min; 130 K-300 K range, 5 K/min; Scan 2 - Heating and Cooling rates: 10 K-100 K range, 3 K/min; 105 K-120 K range, 1 K/min; 130 K-300 K range, 5 K/min; Scan 3 - Heating and Cooling rates: 10 K-100 K range, 3 K/min; 105 K-120 K range, 5 K/min; 130 K-300 K range, 5 K/min.
    • Scan 1 - Heating rates: 10 K-100 K range, 1 K/min; 105 K-120 K range, 2 K/min; 130 K-300 K range, 5 K/min, Cooling rates: 10 K-100 K range, 3 K/min; 105 K-120 K range, 2 K/min; 130 K-300 K range, 5 K/min; Scan 2 - Heating and Cooling rates: 10 K-100 K range, 3 K/min; 105 K-120 K range, 1 K/min; 130 K-300 K range, 5 K/min; Scan 3 - Heating and Cooling rates: 10 K-100 K range, 3 K/min; 105 K-120 K range, 5 K/min; 130 K-300 K range, 5 K/min.
  • 28
    • 0003998388 scopus 로고    scopus 로고
    • 88th ed.; CRC Press, Taylor & Francis Group: New York
    • CRC Handbook of Chemistry and Physics. 88th ed.; CRC Press, Taylor & Francis Group: New York, 2008.
    • (2008) CRC Handbook of Chemistry and Physics
  • 31
    • 20544433165 scopus 로고
    • Bondi, A. J. Phys. Chem. 1964, 68(3), 441-451.
    • (1964) J. Phys. Chem. , vol.68 , Issue.3 , pp. 441-451
    • Bondi, A.1
  • 33
    • 77950275210 scopus 로고    scopus 로고
    • II bands reaching a steady state of photoexcitation/photodecay.
    • II bands reaching a steady state of photoexcitation/photodecay.
  • 34
    • 77950206440 scopus 로고    scopus 로고
    • The data from 45 K-55 K are obscured because of a phase transition in oxygen trapped in the sample cavity and has been omitted.
    • The data from 45 K-55 K are obscured because of a phase transition in oxygen trapped in the sample cavity and has been omitted.
  • 39
    • 77950245967 scopus 로고    scopus 로고
    • 3 s. See also Supporting Information, Figures 2 and 3.
    • 3 s. See also Supporting Information, Figures 2 and 3.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.