-
1
-
-
0015250017
-
Tomosynthesis: A three-dimensional radiographic imaging technique
-
Grant DG. Tomosynthesis: a three-dimensional radiographic imaging technique. IEEE Trans Biomed Eng 1972;19(1):20-28.
-
(1972)
Ieee Trans Biomed Eng
, vol.19
, Issue.1
, pp. 20-28
-
-
Grant, D.G.1
-
2
-
-
0141928682
-
Digital x-ray tomosynthesis: Current state of the art and clinical potential
-
Dobbins JT 3rd, Godfrey DJ. Digital x-ray tomosynthesis: current state of the art and clinical potential. Phys Med Biol 2003;48(19):R65-R106.
-
(2003)
Phys Med Biol
, vol.48
, Issue.19
-
-
Dobbins III, J.T.1
Godfrey, D.J.2
-
3
-
-
36148973645
-
Breast tomosynthesis: Present considerations and future applications
-
Park JM, Franken EA Jr, Garg M, Fajardo LL, Niklason LT. Breast tomosynthesis: present considerations and future applications. RadioGraphics 2007;27(Suppl 1):S231-S240.
-
(2007)
Radiographics
, vol.27
, Issue.SUPPL. 1
-
-
Park, J.M.1
Franken Jr., E.A.2
Garg, M.3
Fajardo, L.L.4
Niklason, L.T.5
-
4
-
-
33846655389
-
Recent advances in chest radiography
-
McAdams HP, Samei E, Dobbins J 3rd, Tourassi GD, Ravin CE. Recent advances in chest radiography. Radiology 2006;241(3):663-683.
-
(2006)
Radiology
, vol.241
, Issue.3
, pp. 663-683
-
-
McAdams, H.P.1
Samei, E.2
Dobbins III, J.3
Tourassi, G.D.4
Ravin, C.E.5
-
5
-
-
58149198701
-
Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: Human observer study of clinical cases
-
Vikgren J, Zachrisson S, Svalkvist A, et al. Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 2008;249 (3):1034-1041.
-
(2008)
Radiology
, vol.249
, Issue.3
, pp. 1034-1041
-
-
Vikgren, J.1
Zachrisson, S.2
Svalkvist, A.3
-
6
-
-
35148861836
-
Effect of acquisition parameters on image quality in digital tomosynthesis
-
65101L
-
Deller T, Jabri KN, Sabol JM, et al. Effect of acquisition parameters on image quality in digital tomosynthesis. Proc SPIE 2007; 6510:65101L.
-
(2007)
Proc Spie
, vol.6510
-
-
Deller, T.1
Jabri, K.N.2
Sabol, J.M.3
-
7
-
-
66749112804
-
-
U.S. patent 7457451
-
Hsieh J, Metz SW, Avinash GB, Li B, Sabol JM. Systems, methods and apparatus for specialized filtered back-projection reconstruction for digital tomosynthesis. U.S. patent 7457451, 2008.
-
(2008)
Systems, Methods and Apparatus For Specialized Filtered Back-projection Reconstruction For Digital Tomosynthesis
-
-
Hsieh, J.1
Metz, S.W.2
Avinash, G.B.3
Li, B.4
Sabol, J.M.5
-
8
-
-
66749129185
-
Dose assessment of digital tomosynthesis in pediatric imaging
-
Gislason A, Elbakri IA, Reed M. Dose assessment of digital tomosynthesis in pediatric imaging. Proc SPIE 2009; 7258.
-
(2009)
Proc Spie
, pp. 7258
-
-
Gislason, A.1
Elbakri, I.A.2
Reed, M.3
-
9
-
-
72049095305
-
A Monte Carlo estimation of effective dose in chest tomosynthesis
-
Sabol JM. A Monte Carlo estimation of effective dose in chest tomosynthesis. Med Phys 2009;36 (12):5480-5487.
-
(2009)
Med Phys
, vol.36
, Issue.12
, pp. 5480-5487
-
-
Sabol, J.M.1
-
10
-
-
47249166093
-
Effective doses in radiology and diagnostic nuclear medicine: A catalog
-
Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 2008;248(1):254-263.
-
(2008)
Radiology
, vol.248
, Issue.1
, pp. 254-263
-
-
Mettler Jr., F.A.1
Huda, W.2
Yoshizumi, T.T.3
Mahesh, M.4
-
11
-
-
0004010332
-
Body section radiography
-
In: Murry RC, Dowdey JE, Christensen EE, eds., 4th ed. Philadelphia, Pa: Lea & Febiger
-
Curry TS, Dowdey JE, Murry RC. Body section radiography. In: Murry RC, Dowdey JE, Christensen EE, eds. Christensen's physics of diagnostic radiology. 4th ed. Philadelphia, Pa: Lea & Febiger, 1990; 242-256.
-
(1990)
Christensen's Physics of Diagnostic Radiology
, pp. 242-256
-
-
Curry, T.S.1
Dowdey, J.E.2
Murry, R.C.3
-
12
-
-
34347393496
-
Optimization of slice sensitivity profile for radiographic tomosynthesis
-
Li B, Avinash GB, Eberhard JW, Claus BE. Optimization of slice sensitivity profile for radiographic tomosynthesis. Med Phys 2007;34(7):2907-2916.
-
(2007)
Med Phys
, vol.34
, Issue.7
, pp. 2907-2916
-
-
Li, B.1
Avinash, G.B.2
Eberhard, J.W.3
Claus, B.E.4
-
13
-
-
0032886190
-
The pathology of total joint arthroplasty. I. Mechanisms of implant fixation
-
Bauer TW, Schils J. The pathology of total joint arthroplasty. I. Mechanisms of implant fixation. Skeletal Radiol 1999;28(8):423-432.
-
(1999)
Skeletal Radiol
, vol.28
, Issue.8
, pp. 423-432
-
-
Bauer, T.W.1
Schils, J.2
-
14
-
-
0032881417
-
The pathology of total joint arthroplasty. II. Mechanisms of implant failure
-
Bauer TW, Schils J. The pathology of total joint arthroplasty. II. Mechanisms of implant failure. Skeletal Radiol 1999;28(9):483-497.
-
(1999)
Skeletal Radiol
, vol.28
, Issue.9
, pp. 483-497
-
-
Bauer, T.W.1
Schils, J.2
-
15
-
-
49749139314
-
Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty
-
Gomi T, Hirano H. Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty. J Digit Imaging 2008;21(3):312-322.
-
(2008)
J Digit Imaging
, vol.21
, Issue.3
, pp. 312-322
-
-
Gomi, T.1
Hirano, H.2
-
16
-
-
42649126007
-
Use of digital tomosynthesis: Case report of a suspected scaphoid fracture and technique
-
Mermuys K, Vanslambrouck K, Goubau J, Steyaert L, Casselman JW. Use of digital tomosynthesis: case report of a suspected scaphoid fracture and technique. Skeletal Radiol 2008;37(6):569-572.
-
(2008)
Skeletal Radiol
, vol.37
, Issue.6
, pp. 569-572
-
-
Mermuys, K.1
Vanslambrouck, K.2
Goubau, J.3
Steyaert, L.4
Casselman, J.W.5
|