메뉴 건너뛰기




Volumn 30, Issue 2, 2010, Pages 549-562

Optimizing parameters for flat-panel detector digital tomosynthesis

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; EQUIPMENT DESIGN; HUMAN; IMAGE QUALITY; INSTRUMENTATION; METHODOLOGY; X RAY FILM;

EID: 77950164162     PISSN: 02715333     EISSN: 15271323     Source Type: Journal    
DOI: 10.1148/rg.302095097     Document Type: Article
Times cited : (77)

References (16)
  • 1
    • 0015250017 scopus 로고
    • Tomosynthesis: A three-dimensional radiographic imaging technique
    • Grant DG. Tomosynthesis: a three-dimensional radiographic imaging technique. IEEE Trans Biomed Eng 1972;19(1):20-28.
    • (1972) Ieee Trans Biomed Eng , vol.19 , Issue.1 , pp. 20-28
    • Grant, D.G.1
  • 2
    • 0141928682 scopus 로고    scopus 로고
    • Digital x-ray tomosynthesis: Current state of the art and clinical potential
    • Dobbins JT 3rd, Godfrey DJ. Digital x-ray tomosynthesis: current state of the art and clinical potential. Phys Med Biol 2003;48(19):R65-R106.
    • (2003) Phys Med Biol , vol.48 , Issue.19
    • Dobbins III, J.T.1    Godfrey, D.J.2
  • 5
    • 58149198701 scopus 로고    scopus 로고
    • Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: Human observer study of clinical cases
    • Vikgren J, Zachrisson S, Svalkvist A, et al. Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 2008;249 (3):1034-1041.
    • (2008) Radiology , vol.249 , Issue.3 , pp. 1034-1041
    • Vikgren, J.1    Zachrisson, S.2    Svalkvist, A.3
  • 6
    • 35148861836 scopus 로고    scopus 로고
    • Effect of acquisition parameters on image quality in digital tomosynthesis
    • 65101L
    • Deller T, Jabri KN, Sabol JM, et al. Effect of acquisition parameters on image quality in digital tomosynthesis. Proc SPIE 2007; 6510:65101L.
    • (2007) Proc Spie , vol.6510
    • Deller, T.1    Jabri, K.N.2    Sabol, J.M.3
  • 8
    • 66749129185 scopus 로고    scopus 로고
    • Dose assessment of digital tomosynthesis in pediatric imaging
    • Gislason A, Elbakri IA, Reed M. Dose assessment of digital tomosynthesis in pediatric imaging. Proc SPIE 2009; 7258.
    • (2009) Proc Spie , pp. 7258
    • Gislason, A.1    Elbakri, I.A.2    Reed, M.3
  • 9
    • 72049095305 scopus 로고    scopus 로고
    • A Monte Carlo estimation of effective dose in chest tomosynthesis
    • Sabol JM. A Monte Carlo estimation of effective dose in chest tomosynthesis. Med Phys 2009;36 (12):5480-5487.
    • (2009) Med Phys , vol.36 , Issue.12 , pp. 5480-5487
    • Sabol, J.M.1
  • 10
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: A catalog
    • Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 2008;248(1):254-263.
    • (2008) Radiology , vol.248 , Issue.1 , pp. 254-263
    • Mettler Jr., F.A.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4
  • 11
    • 0004010332 scopus 로고
    • Body section radiography
    • In: Murry RC, Dowdey JE, Christensen EE, eds., 4th ed. Philadelphia, Pa: Lea & Febiger
    • Curry TS, Dowdey JE, Murry RC. Body section radiography. In: Murry RC, Dowdey JE, Christensen EE, eds. Christensen's physics of diagnostic radiology. 4th ed. Philadelphia, Pa: Lea & Febiger, 1990; 242-256.
    • (1990) Christensen's Physics of Diagnostic Radiology , pp. 242-256
    • Curry, T.S.1    Dowdey, J.E.2    Murry, R.C.3
  • 12
    • 34347393496 scopus 로고    scopus 로고
    • Optimization of slice sensitivity profile for radiographic tomosynthesis
    • Li B, Avinash GB, Eberhard JW, Claus BE. Optimization of slice sensitivity profile for radiographic tomosynthesis. Med Phys 2007;34(7):2907-2916.
    • (2007) Med Phys , vol.34 , Issue.7 , pp. 2907-2916
    • Li, B.1    Avinash, G.B.2    Eberhard, J.W.3    Claus, B.E.4
  • 13
    • 0032886190 scopus 로고    scopus 로고
    • The pathology of total joint arthroplasty. I. Mechanisms of implant fixation
    • Bauer TW, Schils J. The pathology of total joint arthroplasty. I. Mechanisms of implant fixation. Skeletal Radiol 1999;28(8):423-432.
    • (1999) Skeletal Radiol , vol.28 , Issue.8 , pp. 423-432
    • Bauer, T.W.1    Schils, J.2
  • 14
    • 0032881417 scopus 로고    scopus 로고
    • The pathology of total joint arthroplasty. II. Mechanisms of implant failure
    • Bauer TW, Schils J. The pathology of total joint arthroplasty. II. Mechanisms of implant failure. Skeletal Radiol 1999;28(9):483-497.
    • (1999) Skeletal Radiol , vol.28 , Issue.9 , pp. 483-497
    • Bauer, T.W.1    Schils, J.2
  • 15
    • 49749139314 scopus 로고    scopus 로고
    • Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty
    • Gomi T, Hirano H. Clinical potential of digital linear tomosynthesis imaging of total joint arthroplasty. J Digit Imaging 2008;21(3):312-322.
    • (2008) J Digit Imaging , vol.21 , Issue.3 , pp. 312-322
    • Gomi, T.1    Hirano, H.2
  • 16
    • 42649126007 scopus 로고    scopus 로고
    • Use of digital tomosynthesis: Case report of a suspected scaphoid fracture and technique
    • Mermuys K, Vanslambrouck K, Goubau J, Steyaert L, Casselman JW. Use of digital tomosynthesis: case report of a suspected scaphoid fracture and technique. Skeletal Radiol 2008;37(6):569-572.
    • (2008) Skeletal Radiol , vol.37 , Issue.6 , pp. 569-572
    • Mermuys, K.1    Vanslambrouck, K.2    Goubau, J.3    Steyaert, L.4    Casselman, J.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.