메뉴 건너뛰기




Volumn 46, Issue 2, 2010, Pages 118-120

Common-path optical coherence tomography guided fibre probe for spatially precise optical nerve stimulation

Author keywords

[No Author keywords available]

Indexed keywords

AXIAL RESOLUTIONS; COMMON-PATH; FIBRE PROBE; LASER POWER DELIVERY; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL NERVES; REAL TIME MONITORING;

EID: 77949968799     PISSN: 00135194     EISSN: None     Source Type: Journal    
DOI: 10.1049/el.2010.3221     Document Type: Article
Times cited : (19)

References (7)
  • 2
    • 34848870813 scopus 로고    scopus 로고
    • Biophysical mechanisms of transient optical stimulation of peripheral nerve
    • 0006-3495
    • Wells, J., Kao, C., Konrad, P., Milner, T., Kim, J., Mahadevanjansen, A., and Jansen, E.: ' Biophysical mechanisms of transient optical stimulation of peripheral nerve ', Biophys. J., 2007, 93, p. 2567-2580 0006-3495
    • (2007) Biophys. J. , vol.93 , pp. 2567-2580
    • Wells, J.1    Kao, C.2    Konrad, P.3    Milner, T.4    Kim, J.5    Mahadevanjansen, A.6    Jansen, E.7
  • 3
    • 77949957449 scopus 로고    scopus 로고
    • Application Note - Rat Sciatic Nerve, 12/6/06, Revision: 01
    • Application Note - Rat Sciatic Nerve, 12/6/06, Revision: 01, (http://www.aculight.com/infrarednervestimulator.html)
  • 4
    • 69549106178 scopus 로고    scopus 로고
    • A surface topology and motion compensation system for microsurgery guidance and intervention based on common-path optical coherence tomography
    • 0018-9294
    • Zhang, K., Wang, W., Han, J., and Kang, J.U.: ' A surface topology and motion compensation system for microsurgery guidance and intervention based on common-path optical coherence tomography ', IEEE Trans. Biomed. Eng., 2009, 56, p. 2318-2321 0018-9294
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , pp. 2318-2321
    • Zhang, K.1    Wang, W.2    Han, J.3    Kang, J.U.4
  • 5
    • 70350517128 scopus 로고    scopus 로고
    • Common path optical coherence tomography with fibre bundle probe
    • 0013-5194
    • Han, J., Liu, X., Song, C.G., and Kang, J.U.: ' Common path optical coherence tomography with fibre bundle probe ', Electron. Lett., 2009, 45, p. 1110-1112 0013-5194
    • (2009) Electron. Lett. , vol.45 , pp. 1110-1112
    • Han, J.1    Liu, X.2    Song, C.G.3    Kang, J.U.4
  • 6
    • 84975664117 scopus 로고
    • Ray tracing of optically modified fibre tips. 1: Spherical probes
    • 0003-6935
    • Verdaasdonk, R.M., and Borst, C.: ' Ray tracing of optically modified fibre tips. 1: Spherical probes ', Appl. Opt., 1991, 30, p. 2159-2171 0003-6935
    • (1991) Appl. Opt. , vol.30 , pp. 2159-2171
    • Verdaasdonk, R.M.1    Borst, C.2
  • 7
    • 65949098413 scopus 로고    scopus 로고
    • Effects of optical irradiation parameters on safe peripheral nerve stimulation with infrared light
    • Katz, E., Kim, D.H., Ilev, I.K., and Krauthamer, V.: ' Effects of optical irradiation parameters on safe peripheral nerve stimulation with infrared light ', Proc. SPIE, 2009, 7180, p. 71800P-1
    • (2009) Proc. SPIE , vol.7180
    • Katz, E.1    Kim, D.H.2    Ilev, I.K.3    Krauthamer, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.