-
1
-
-
0004091542
-
-
Bianchi E., Bowman-James K., and Garcia-Espana E. (Eds), Wiley-VCH, New York
-
In: Bianchi E., Bowman-James K., and Garcia-Espana E. (Eds). Supramolecular Chemistry of Anions (1997), Wiley-VCH, New York
-
(1997)
Supramolecular Chemistry of Anions
-
-
-
2
-
-
17544398524
-
Fluorogenic and chromogenic chemosensors and reagents for anions
-
Martinez-Manez R., and Sancenon F. Fluorogenic and chromogenic chemosensors and reagents for anions. Chem. Rev. 103 (2003) 4419-4476
-
(2003)
Chem. Rev.
, vol.103
, pp. 4419-4476
-
-
Martinez-Manez, R.1
Sancenon, F.2
-
3
-
-
0003692166
-
-
The Benjamin/Cummings Publishing Co., Inc., Redwood City, CA
-
Mathews C.P., and van Hold K.E. Biochemistry (1990), The Benjamin/Cummings Publishing Co., Inc., Redwood City, CA
-
(1990)
Biochemistry
-
-
Mathews, C.P.1
van Hold, K.E.2
-
4
-
-
0030298490
-
Real-time DNA sequencing using detection of pyrophosphate release
-
Ronaghi M., Karamohamed S., Pettersson B., Uhlén M., and Nyrén P. Real-time DNA sequencing using detection of pyrophosphate release. Anal. Biochem. 242 (1996) 84-89
-
(1996)
Anal. Biochem.
, vol.242
, pp. 84-89
-
-
Ronaghi, M.1
Karamohamed, S.2
Pettersson, B.3
Uhlén, M.4
Nyrén, P.5
-
5
-
-
0035894366
-
A quantitative method to measure telomerase activity by bioluminescence connected with telomeric repeat amplification protocol
-
Xu S., He M., Yu H., Cai X., Tan X., Lu B., and Shu B. A quantitative method to measure telomerase activity by bioluminescence connected with telomeric repeat amplification protocol. Anal. Biochem. 299 (2001) 188-193
-
(2001)
Anal. Biochem.
, vol.299
, pp. 188-193
-
-
Xu, S.1
He, M.2
Yu, H.3
Cai, X.4
Tan, X.5
Lu, B.6
Shu, B.7
-
6
-
-
33846634179
-
Simple, but an effective way to sense pyrophosphate and inorganic phosphate by fluorescence changes
-
Lee H.N., Swamy K.M.K., Kim S.K., Kwon J.-Y., Kim Y., Kim S.-J., Yoon Y.J., and Yoon J. Simple, but an effective way to sense pyrophosphate and inorganic phosphate by fluorescence changes. Org. Lett. 9 (2007) 243-246
-
(2007)
Org. Lett.
, vol.9
, pp. 243-246
-
-
Lee, H.N.1
Swamy, K.M.K.2
Kim, S.K.3
Kwon, J.-Y.4
Kim, Y.5
Kim, S.-J.6
Yoon, Y.J.7
Yoon, J.8
-
8
-
-
17144389333
-
A fluorescent pyrophosphate sensor via eximer formation in water
-
Cho H.K., Lee D.H., and Hong J.-I. A fluorescent pyrophosphate sensor via eximer formation in water. Chem. Commun. (2005) 1690-1692
-
(2005)
Chem. Commun.
, pp. 1690-1692
-
-
Cho, H.K.1
Lee, D.H.2
Hong, J.-I.3
-
9
-
-
4644233703
-
A fluorescent pyrophosphate sensor with high selectivity over ATP in water
-
Lee D.H., Kim S.Y., and Hong J.-I. A fluorescent pyrophosphate sensor with high selectivity over ATP in water. Angew. Chem. Int. Ed. 43 (2004) 4777-4780
-
(2004)
Angew. Chem. Int. Ed.
, vol.43
, pp. 4777-4780
-
-
Lee, D.H.1
Kim, S.Y.2
Hong, J.-I.3
-
10
-
-
1842830224
-
Sensing of aqueous phosphates by polymers with dual modes of signal transduction
-
Aldakov D., and Anzenbacher Jr. P. Sensing of aqueous phosphates by polymers with dual modes of signal transduction. J. Am. Chem. Soc. 126 (2004) 4752-4753
-
(2004)
J. Am. Chem. Soc.
, vol.126
, pp. 4752-4753
-
-
Aldakov, D.1
Anzenbacher Jr., P.2
-
11
-
-
0037123235
-
A fluorescent anion sensor that works in neutral aqueous solution for bioanalytical application
-
Mizukami S., Nagano T., Urano Y., Odani A., and Kikuchi K. A fluorescent anion sensor that works in neutral aqueous solution for bioanalytical application. J. Am. Chem. Soc. 124 (2002) 3920-3925
-
(2002)
J. Am. Chem. Soc.
, vol.124
, pp. 3920-3925
-
-
Mizukami, S.1
Nagano, T.2
Urano, Y.3
Odani, A.4
Kikuchi, K.5
-
12
-
-
0028005741
-
Real-time assay of inorganic pyrophosphatase using a high-affinity chelation-enhanced fluorescence chemosensor
-
Vance D.H., and Czarnik A.W. Real-time assay of inorganic pyrophosphatase using a high-affinity chelation-enhanced fluorescence chemosensor. J. Am. Chem. Soc. 116 (1994) 9397-9398
-
(1994)
J. Am. Chem. Soc.
, vol.116
, pp. 9397-9398
-
-
Vance, D.H.1
Czarnik, A.W.2
-
13
-
-
33745864028
-
Selective recognition of pyrophosphate in water using a backbone modified cyclic peptide receptor
-
McDonough M.J., Reynolds A.J., Lee W.Y.G., and Jolliffe K.A. Selective recognition of pyrophosphate in water using a backbone modified cyclic peptide receptor. Chem. Commun. (2006) 2971-2973
-
(2006)
Chem. Commun.
, pp. 2971-2973
-
-
McDonough, M.J.1
Reynolds, A.J.2
Lee, W.Y.G.3
Jolliffe, K.A.4
-
14
-
-
7044254951
-
An indicator displacement system for fluorescent detection of phosphate oxyanions under physiological conditions
-
Hanshaw R.G., Hilkert S.M., Jiang H., and Smith B.D. An indicator displacement system for fluorescent detection of phosphate oxyanions under physiological conditions. Tetrahedron Lett. 45 (2004) 8721-8724
-
(2004)
Tetrahedron Lett.
, vol.45
, pp. 8721-8724
-
-
Hanshaw, R.G.1
Hilkert, S.M.2
Jiang, H.3
Smith, B.D.4
-
15
-
-
0037131435
-
Pyrophosphate detection in water by fluorescence competition assay: inducing selectivity through the choice of the indicator
-
Fabbrizzi L., Marcotte N., Stomeo F., and Taglietti A. Pyrophosphate detection in water by fluorescence competition assay: inducing selectivity through the choice of the indicator. Angew. Chem. Int. Ed. 41 (2002) 3811-3814
-
(2002)
Angew. Chem. Int. Ed.
, vol.41
, pp. 3811-3814
-
-
Fabbrizzi, L.1
Marcotte, N.2
Stomeo, F.3
Taglietti, A.4
-
16
-
-
0035803061
-
Colorimetric anion sensing by porphyrin-based anion receptors
-
Lee C., Lee D.H., and Hong J.-I. Colorimetric anion sensing by porphyrin-based anion receptors. Tetrahedron Lett. 42 (2001) 8665-8668
-
(2001)
Tetrahedron Lett.
, vol.42
, pp. 8665-8668
-
-
Lee, C.1
Lee, D.H.2
Hong, J.-I.3
-
17
-
-
0035817278
-
Fluoride-selective chromogenic sensors based on azophenol
-
Lee K.H., Lee H.-Y., Lee D.H., and Hong J.-I. Fluoride-selective chromogenic sensors based on azophenol. Tetrahedron Lett. 42 (2001) 5447-5449
-
(2001)
Tetrahedron Lett.
, vol.42
, pp. 5447-5449
-
-
Lee, K.H.1
Lee, H.-Y.2
Lee, D.H.3
Hong, J.-I.4
-
18
-
-
0034715470
-
Fluorinated calix[4]pyrrole and dipyrrolylquinoxaline: neutral anion receptors with augmented affinities and enhanced selectivities
-
Anzenbacher Jr. P., Try A.C., Miyaji H., Jursikova K., Lynch V.M., Marquez M., and Sessler J.L. Fluorinated calix[4]pyrrole and dipyrrolylquinoxaline: neutral anion receptors with augmented affinities and enhanced selectivities. J. Am. Chem. Soc. 122 (2000) 10268-10272
-
(2000)
J. Am. Chem. Soc.
, vol.122
, pp. 10268-10272
-
-
Anzenbacher Jr., P.1
Try, A.C.2
Miyaji, H.3
Jursikova, K.4
Lynch, V.M.5
Marquez, M.6
Sessler, J.L.7
-
20
-
-
4544280307
-
Highly selective oligonucleotide-based sensor for mercury(II) in aqueous solutions
-
Detection limit is defined by 3σ/K. Here σ and K refer to the standard deviation of the blank solutions and the slope (σ) of the linear regression curve observed in Fig. 6b, respectively, see
-
Detection limit is defined by 3σ/K. Here σ and K refer to the standard deviation of the blank solutions and the slope (σ) of the linear regression curve observed in Fig. 6b, respectively, see. Ono A., and Togashi H. Highly selective oligonucleotide-based sensor for mercury(II) in aqueous solutions. Angew. Chem. Int. Ed. 43 (2004) 4300-4302
-
(2004)
Angew. Chem. Int. Ed.
, vol.43
, pp. 4300-4302
-
-
Ono, A.1
Togashi, H.2
-
21
-
-
33750045748
-
Anion recognition by a silanediol-based receptor
-
Kondo S.-I., Harada T., Tanaka R., and Unno M. Anion recognition by a silanediol-based receptor. Org. Lett. 8 (2006) 4621-4624
-
(2006)
Org. Lett.
, vol.8
, pp. 4621-4624
-
-
Kondo, S.-I.1
Harada, T.2
Tanaka, R.3
Unno, M.4
-
22
-
-
29944443016
-
Colorimetric "Naked Eye" sensing of anions in aqueous solution
-
Gunnlaugsson T., Kruger P.E., Jensen P., Tierney J., Ali H.D.P., and Hussey G.M. Colorimetric "Naked Eye" sensing of anions in aqueous solution. J. Org. Chem. 70 (2005) 10875-10878
-
(2005)
J. Org. Chem.
, vol.70
, pp. 10875-10878
-
-
Gunnlaugsson, T.1
Kruger, P.E.2
Jensen, P.3
Tierney, J.4
Ali, H.D.P.5
Hussey, G.M.6
-
23
-
-
33947328112
-
Fluorescence yields of aromatic compounds
-
The fluorescence quantum yields were measured with respect to anthracene as standard (Φ = 0.27 ± 0.03)
-
The fluorescence quantum yields were measured with respect to anthracene as standard (Φ = 0.27 ± 0.03). Dawson W.R., and Windsor M.W. Fluorescence yields of aromatic compounds. J. Phys. Chem. 72 (1968) 3251-3260
-
(1968)
J. Phys. Chem.
, vol.72
, pp. 3251-3260
-
-
Dawson, W.R.1
Windsor, M.W.2
|