메뉴 건너뛰기




Volumn 25, Issue 8, 2009, Pages 73-76

Surface acoustic wave (SAW) biosensor chip system - A promising alternative for biomedical applications

Author keywords

Biomedical applications; Biosensors; Immobilization; Label free; Surface acoustic wave

Indexed keywords

ACOUSTIC SURFACE WAVE DEVICES; ACOUSTIC WAVES; BIOMEDICAL ENGINEERING; COST EFFECTIVENESS; FLUIDIC DEVICES; MEDICAL APPLICATIONS; MEDICAL PHYSICS; MEDICINE; MICROFLUIDICS; NANOSYSTEMS; RADIOACTIVE WASTE VITRIFICATION; SHEAR FLOW; SHEAR WAVES; SURFACE REACTIONS; SURFACE WAVES; WAVE PROPAGATION;

EID: 77949886051     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03887-7_20     Document Type: Conference Paper
Times cited : (7)

References (6)
  • 1
    • 0038796897 scopus 로고    scopus 로고
    • Serum HER-2/neu in the management of breast cancer patients
    • Lüftner D., Lüke C. et al (2003) Serum HER-2/neu in the management of breast cancer patients. Clin. Biochem. 36: 233-240
    • (2003) Clin. Biochem , vol.36 , pp. 233-240
    • Lüftner, D.1    Lüke, C.2
  • 2
    • 45849085364 scopus 로고    scopus 로고
    • Surface acoustic wave biosensors: A review
    • Länge K., Rapp B. E. et al (2008) Surface acoustic wave biosensors: a review. Anal. Bioanal. Chem 391: 1509-1519
    • (2008) Anal. Bioanal. Chem , vol.391 , pp. 1509-1519
    • Länge, K.1    Rapp, B.E.2
  • 3
    • 43049138335 scopus 로고    scopus 로고
    • Influence of intermediate aminodextran layers on the signal response of surface acoustic wave biosensors
    • Länge K., Rapp M. (2008) Influence of intermediate aminodextran layers on the signal response of surface acoustic wave biosensors. Anal. Biochem. 377: 170-175
    • (2008) Anal. Biochem , vol.377 , pp. 170-175
    • Länge, K.1    Rapp, M.2
  • 4
    • 18744428328 scopus 로고    scopus 로고
    • A surface acoustic wave biosensor concept with low flow cell volumes for label-free detection
    • Länge K., Bender F. et al (2003) A surface acoustic wave biosensor concept with low flow cell volumes for label-free detection. Anal. Chem. 75: 5561-5566
    • (2003) Anal. Chem , vol.75 , pp. 5561-5566
    • Länge, K.1    Bender, F.2
  • 5
    • 68149132789 scopus 로고    scopus 로고
    • Microfluidic injection analysis (FIA) System allowing Diffusion Free and Indirect pumping of Liquids by Using Tetradecanes as Intermediary Liquid
    • Rapp B. E., Carneiro L. et al (2009) Microfluidic injection analysis (FIA) System allowing Diffusion Free and Indirect pumping of Liquids by Using Tetradecanes as Intermediary Liquid. Lab Chip 9: 354-356
    • (2009) Lab Chip , vol.9 , pp. 354-356
    • Rapp, B.E.1    Carneiro, L.2
  • 6
    • 12144285918 scopus 로고    scopus 로고
    • On-line monitoring of polymer deposition for tailoring the waveguide characteristics of Love-wave biosensors
    • Bender F., Länge K. et al (2004) On-line monitoring of polymer deposition for tailoring the waveguide characteristics of Love-wave biosensors. Langmuir 20: 3215-2319
    • (2004) Langmuir , vol.20 , pp. 3215-2319
    • Bender, F.1    Länge, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.