메뉴 건너뛰기




Volumn 25, Issue 7, 2009, Pages 331-334

Cancer detection probe combining raman and resonance sensor technology - Experimental study on temperature dependence and effects of molding

Author keywords

Frequency shift; Prostate cancer; Raman spectroscopy; Resonance frequency; Tactile resonance

Indexed keywords

BIOMEDICAL ENGINEERING; DIAGNOSIS; FIBER OPTICS; MEDICAL PHYSICS; MOLDING; NATURAL FREQUENCIES; OPTICAL SYSTEMS; PROBES; RAMAN SPECTROSCOPY; STEEL FIBERS; TEMPERATURE DISTRIBUTION; UROLOGY;

EID: 77949850443     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03885-3_92     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 1
    • 0035467993 scopus 로고    scopus 로고
    • Global cancer statistics in the year 2000
    • Parkin, D.M., (2001) Global cancer statistics in the year 2000. The Lancet Oncology. 2(9): p. 533-543
    • (2001) The Lancet Oncology , vol.2 , Issue.9 , pp. 533-543
    • Parkin, D.M.1
  • 2
    • 0032879079 scopus 로고    scopus 로고
    • A catheter tactile sensor for measuring hardness of soft tissue: Measurement in a silicone model and in an in vitro human prostate model
    • Eklund, A., A. Bergh, and O.A. Lindahl, (1999) A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model. Med Biol Eng Comput. 37(5): p. 618-24
    • (1999) Med Biol Eng Comput , vol.37 , Issue.5 , pp. 618-624
    • Eklund, A.1    Bergh, A.2    Lindahl, O.A.3
  • 3
    • 36049045808 scopus 로고    scopus 로고
    • Spatial variations in prostate tissue histology as measured by a tactile resonance sensor
    • Jalkanen, V., et al., (2007) Spatial variations in prostate tissue histology as measured by a tactile resonance sensor. Physiol Meas. 28(10): p. 1267-81
    • (2007) Physiol Meas , vol.28 , Issue.10 , pp. 1267-1281
    • Jalkanen, V.1
  • 4
    • 8644276502 scopus 로고    scopus 로고
    • Raman Spectroscopy for the Detection of Cancers and Precancers
    • Mahadevan-Jansen, A. and R. Richards-Kortum, (1996) Raman Spectroscopy for the Detection of Cancers and Precancers. Journal of Biomedical Optics. 1(1): p. 31-70
    • (1996) Journal of Biomedical Optics , vol.1 , Issue.1 , pp. 31-70
    • Mahadevan-Jansen, A.1    Richards-Kortum, R.2
  • 5
    • 0033935317 scopus 로고    scopus 로고
    • Objective evaluation of liver consistency to estimate hepatic fibrosis and functional reserve for hepatectomy
    • Kusaka, K., et al., (2000) Objective evaluation of liver consistency to estimate hepatic fibrosis and functional reserve for hepatectomy. J Am Coll Surg.191(1): p. 47-53
    • (2000) J Am Coll Surg , vol.191 , Issue.1 , pp. 47-53
    • Kusaka, K.1
  • 6
    • 0029153672 scopus 로고
    • Application of a new tactile sensor to thoracoscopic surgery: Experimental and clinical study
    • discussion 614
    • Ohtsuka, T., et al., (1995) Application of a new tactile sensor to thoracoscopic surgery: experimental and clinical study. Ann Thorac Surg. 60(3): p. 610-3; discussion 614
    • (1995) Ann Thorac Surg , vol.60 , Issue.3 , pp. 610-613
    • Ohtsuka, T.1
  • 7
    • 41349121773 scopus 로고    scopus 로고
    • Development of a new instrument for examination of stiffness in the breast using haptic sensor technology
    • Murayama, Y., et al., (2008) Development of a new instrument for examination of stiffness in the breast using haptic sensor technology. Sensors and Actuators A: Physical. 143(2): p. 430-438
    • (2008) Sensors and Actuators A: Physical , vol.143 , Issue.2 , pp. 430-438
    • Murayama, Y.1
  • 8
    • 0030716235 scopus 로고    scopus 로고
    • The stiffness of lymph nodes containing lung carcinoma metastases: A new diagnostic parameter measured by a tactile sensor
    • Miyaji, K., et al., (1997) The stiffness of lymph nodes containing lung carcinoma metastases: a new diagnostic parameter measured by a tactile sensor. Cancer. 80(10): p. 1920-5
    • (1997) Cancer , vol.80 , Issue.10 , pp. 1920-1925
    • Miyaji, K.1
  • 9
    • 33746912294 scopus 로고    scopus 로고
    • Prostate tissue stiffness as measured with a resonance sensor system: A study on silicone and human prostate tissue in vitro
    • Jalkanen, V., et al., (2006) Prostate tissue stiffness as measured with a resonance sensor system: a study on silicone and human prostate tissue in vitro. Med Biol Eng Comput. 44(7): p. 593-603
    • (2006) Med Biol Eng Comput , vol.44 , Issue.7 , pp. 593-603
    • Jalkanen, V.1
  • 10
    • 77949800583 scopus 로고    scopus 로고
    • Morgan Electro Ceramics, 2007, Piezoelectric Ceramics Properties & Applications at www.morganelectroceramics.com.
    • Morgan Electro Ceramics, 2007, Piezoelectric Ceramics Properties & Applications at www.morganelectroceramics.com.
  • 11
    • 0033863370 scopus 로고    scopus 로고
    • A resonator sensor for measurement of intraocular pressure - evaluation in an in vitro pig-eye model
    • Eklund, A., T. Backlund, and O.A. Lindahl, (2000) A resonator sensor for measurement of intraocular pressure - evaluation in an in vitro pig-eye model. Physiol Meas. 21(3): p. 355-67
    • (2000) Physiol Meas , vol.21 , Issue.3 , pp. 355-367
    • Eklund, A.1    Backlund, T.2    Lindahl, O.A.3
  • 12
    • 4344682145 scopus 로고    scopus 로고
    • Applanation resonance tonometry for intraocular pressure in humans
    • Hallberg, P., et al., (2004) Applanation resonance tonometry for intraocular pressure in humans. Physiol Meas. 25(4): p. 1053-65
    • (2004) Physiol Meas , vol.25 , Issue.4 , pp. 1053-1065
    • Hallberg, P.1
  • 14
    • 55949130888 scopus 로고    scopus 로고
    • Temperature dependence of piezoelectric properties on Nd and V co-substituted Bi4Ti3O12 ceramics for ceramic resonator applications
    • Nagata, H., et al., (2009) Temperature dependence of piezoelectric properties on Nd and V co-substituted Bi4Ti3O12 ceramics for ceramic resonator applications. Ceramics International. 35(1): p. 163-167
    • (2009) Ceramics International , vol.35 , Issue.1 , pp. 163-167
    • Nagata, H.1
  • 15
    • 12444327237 scopus 로고    scopus 로고
    • Evaluation of applanation resonator sensors for intra-ocular pressure measurement: Results from clinical and in vitro studies
    • Eklund, A., et al., (2003) Evaluation of applanation resonator sensors for intra-ocular pressure measurement: results from clinical and in vitro studies. Med Biol Eng Comput. 41(2): p. 190-7
    • (2003) Med Biol Eng Comput , vol.41 , Issue.2 , pp. 190-197
    • Eklund, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.