메뉴 건너뛰기




Volumn 41, Issue 2, 2003, Pages 190-197

Evaluation of applanation resonator sensors for intra-ocular pressure measurement: Results from clinical and in vitro studies

Author keywords

Applanation; Eye; Intra ocular pressure; Piezo ceramics; Resonator; Sensor

Indexed keywords

DIAGNOSIS; OPTICAL CORRELATION; SIGNAL PROCESSING;

EID: 12444327237     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02344887     Document Type: Article
Times cited : (20)

References (15)
  • 1
    • 0012866397 scopus 로고    scopus 로고
    • (The Foundation of the American Academy of Ophthalmology, San Francisco, USA) 2000
    • CANTOR, L. (2000): 'Glaucoma' (The Foundation of the American Academy of Ophthalmology, San Francisco, USA, 2000)
    • (2000) 'Glaucoma'
    • Cantor, L.1
  • 2
    • 0016663381 scopus 로고
    • 'Applanation tonometry and central corneal thickness'
    • EHLERS, N., BRAHMSEN, T., and SPERLING, S. (1975): 'Applanation tonometry and central corneal thickness', Acta Ophthalmologica, 53, pp. 34-43
    • (1975) Acta. Ophthalmologica , vol.53 , pp. 34-43
    • Ehlers, N.1    Brahmsen, T.2    Sperling, S.3
  • 3
    • 0031703801 scopus 로고    scopus 로고
    • 'Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo'
    • EISENBERG, D. L., SHERMAN, B. G., MCKEOWN, C. A., and SCHUMAN, J. S. (1998): 'Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo', Ophthalmology, 105, pp. 1173-1181
    • (1998) Ophthalmology , vol.105 , pp. 1173-1181
    • Eisenberg, D.L.1    Sherman, B.G.2    Mckeown, C.A.3    Schuman, J.S.4
  • 4
    • 0032879079 scopus 로고    scopus 로고
    • 'A catheter tactile sensor for measuring hardness of soft tissue: Measurement in a silicone model and in an in vitro human prostate model'
    • EKLUND, A., BERGH, A., and LINDAHL, O. A. (1999): 'A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model', Med. Biol. Eng. Comput., 37, pp. 618-624
    • (1999) Med. Biol. Eng. Comput. , vol.37 , pp. 618-624
    • Eklund, A.1    Bergh, A.2    Lindahl, O.A.3
  • 5
    • 0033863370 scopus 로고    scopus 로고
    • 'A resonator sensor for measurement of intraocular pressure - Evaluation in an in vitro pig-eye model'
    • EKLUND, A., BACKLUND, T., and LINDAHL, O. A. (2000): 'A resonator sensor for measurement of intraocular pressure - evaluation in an in vitro pig-eye model', Physiol. Meas., 21, pp. 355-367
    • (2000) Physiol. Meas. , vol.21 , pp. 355-367
    • Eklund, A.1    Backlund, T.2    Lindahl, O.A.3
  • 6
    • 0001063063 scopus 로고
    • 'Contribution to the theory and practice of tonometry'
    • FRIEDENWALD, J. S. (1937): 'Contribution to the theory and practice of tonometry', Am. J. Ophthalmol., 20, pp. 985-1024
    • (1937) Am. J. Ophthalmol. , vol.20 , pp. 985-1024
    • Friedenwald, J.S.1
  • 7
    • 0002523438 scopus 로고
    • 'Applanation tonometry' NEWELL
    • F. W. (Ed.): (Josiah Macy, Jr. Foundation, 1957)
    • GOLDMANN, H. (1957): 'Applanation tonometry', in NEWELL, F. W. (Ed.): 'Glucoma. Transactions of the Second Conference' (Josiah Macy, Jr. Foundation, 1957), pp. 167-220
    • (1957) 'Glucoma. Transactions of the Second Conference' , pp. 167-220
    • Goldmann, H.1
  • 9
    • 0029056042 scopus 로고
    • 'Clinical comparison of the XPERT non-contact tonometer and the conventional Goldmann applanation tonometer'
    • HANSEN, M. K. (1995): 'Clinical comparison of the XPERT non-contact tonometer and the conventional Goldmann applanation tonometer', Acta Ophthalmol. Scand, 73, pp. 176-180
    • (1995) Acta. Ophthalmol. Scand. , vol.73 , pp. 176-180
    • Hansen, M.K.1
  • 11
    • 0001534165 scopus 로고
    • 'The Goldmann applanation tonometer'
    • MOSES, R. A. (1958): 'The Goldmann applanation tonometer', Am. J. Ophthalmol., 46, pp. 865-869
    • (1958) Am. J. Ophthalmol. , vol.46 , pp. 865-869
    • Moses, R.A.1
  • 12
    • 0026938164 scopus 로고
    • 'New tactile sensor like the human hand and its applications'
    • OMATA, S., and TERUNUMA, Y. (1992): 'New tactile sensor like the human hand and its applications', Sens. & Actuators, 35, pp. 9-15
    • (1992) Sens. & Actuators , vol.35 , pp. 9-15
    • Omata, S.1    Terunuma, Y.2
  • 13
    • 0003994256 scopus 로고    scopus 로고
    • 'Principles of anatomy and physiology'
    • (Harper Collins Collage Publishers, New York, NY, 1996)
    • TORTORA, G. J., and GRABOWSKI, S. R. (1996): 'Principles of anatomy and physiology' (Harper Collins Collage Publishers, New York, NY, 1996)
    • (1996)
    • Tortora, G.J.1    Grabowski, S.R.2
  • 14
    • 0027291601 scopus 로고
    • 'Sources of error with use of Goldmann-type tonometers'
    • WHITACRE, M. M., and STEIN, R. (1993): 'Sources of error with use of Goldmann-type tonometers', Surv. Ophthalmol., 38, pp. 1-30
    • (1993) Surv. Ophthalmol. , vol.38 , pp. 1-30
    • Whitacre, M.M.1    Stein, R.2
  • 15
    • 0027269723 scopus 로고
    • 'The effect of corneal thickness on applanation tonometry'
    • WHITACRE, M. M., STEIN, R. A., and HASSANEIN, K. (1993): 'The effect of corneal thickness on applanation tonometry', Am. J. Ophthalmol., 115, pp. 592-596
    • (1993) Am. J. Ophthalmol. , vol.115 , pp. 592-596
    • Whitacre, M.M.1    Stein, R.A.2    Hassanein, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.