Volumn 25, Issue 7, 2009, Pages 126-129

A new sensory device and optimal position for monitoring HR/RR during sleep

Author keywords

Heart rate; Piezoelectric sensor; Respiration rate; Sleep

Indexed keywords

BIOMEDICAL ENGINEERING; DIAGNOSIS; LEAD COMPOUNDS; MEDICAL PHYSICS; PIEZOELECTRICITY; SLEEP RESEARCH;

EID: 77949809864     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03885-3_36     Document Type: Conference Paper
Times cited : (7)

References (15)
  • 1
    • 0034867841 scopus 로고    scopus 로고
    • Development of real-time image sequence analysis for evaluating posture change and respiratory rate of a subject in bed
    • K. Nakajima, Y. Matsumoto and T. Tamura (2001). Development of real-time image sequence analysis for evaluating posture change and respiratory rate of a subject in bed, Physiological Measurement 22 N21-N28
    • (2001) Physiological Measurement , vol.22
    • Nakajima, K.1    Matsumoto, Y.2    Tamura, T.3
  • 2
    • 34250201117 scopus 로고    scopus 로고
    • Heart rate measurement based on a time-lapse image
    • C. Takano and Y. Ohta, Heart rate measurement based on a time-lapse image. Medical Engineering & Physics , Vol. 29 , No. 8 , pp 853-857, 2007
    • (2007) Medical Engineering & Physics , vol.29 , Issue.8 , pp. 853-857
    • Takano, C.1    Ohta, Y.2
  • 3
    • 20044394397 scopus 로고    scopus 로고
    • Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements
    • Y. Chee, J. Han, J. Youn, and K. Park, "Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements," Physiological Measurement, no. 26, pp. 413-422, 2005
    • (2005) Physiological Measurement , Issue.26 , pp. 413-422
    • Chee, Y.1    Han, J.2    Youn, J.3    Park, K.4
  • 8
    • 18144388211 scopus 로고    scopus 로고
    • Development of biometry system in the sleep by pillow cuff installed on the occiput
    • Japanese Society Med. Biol. Eng
    • K. Watanabe, T. Tasaki, T. Nemoto, K. Yamakoshi, and W. Chen, "Development of biometry system in the sleep by pillow cuff installed on the occiput," Trans. Japanese Society Med. Biol. Eng., vol. 41, Suppl. 1, pp. 168, 2003.
    • (2003) Trans , vol.41 , Issue.SUPPL. 1 , pp. 168
    • Watanabe, K.1    Tasaki, T.2    Nemoto, T.3    Yamakoshi, K.4    Chen, W.5
  • 9
    • 33845580613 scopus 로고    scopus 로고
    • M.H. Jones, R. Goubran, F. Knoefel, Identifying Movement Onset Times for a Bed-Based Pressure Sensor Array, memea, pp. 111-114, IEEE International Workshop on Medical Measurement and Applications, 2006. MeMea 2006., 2006
    • M.H. Jones, R. Goubran, F. Knoefel, "Identifying Movement Onset Times for a Bed-Based Pressure Sensor Array," memea, pp. 111-114, IEEE International Workshop on Medical Measurement and Applications, 2006. MeMea 2006., 2006
  • 10
    • 28844497673 scopus 로고    scopus 로고
    • Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method
    • Dec
    • Watanabe, K. Watanabe, T. Watanabe, H. Ando, H. Ishikawa, T. Kobayashi, K. Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method. IEEE Transactions on Biomedical Engineering, Dec. 2005, Vol. 52, No. 12, pp. 2100-2107
    • (2005) IEEE Transactions on Biomedical Engineering , vol.52 , Issue.12 , pp. 2100-2107
    • Watanabe, K.1    Watanabe, T.2    Watanabe, H.3    Ando, H.4    Ishikawa, T.5    Kobayashi, K.6
  • 12
    • 0026204957 scopus 로고
    • Monitoring of the Ballistocardiogram with the Static Charge Sensitive Bed
    • B. H. Jansen, B. H. Larson, and K. Shankar, Monitoring of the Ballistocardiogram with the Static Charge Sensitive Bed, IEEE Trans. BME. Vol. 38, No. 8. pp. 748-751, 1991
    • (1991) IEEE Trans. BME , vol.38 , Issue.8 , pp. 748-751
    • Jansen, B.H.1    Larson, B.H.2    Shankar, K.3
  • 13
    • 0036261771 scopus 로고    scopus 로고
    • Unconstrained and non-invasive measurement of heart-beat and respiration periods using a phonocardiographic sensor
    • S. Tanaka, Y. Matsumoto and K. Wakimoto, Unconstrained and non-invasive measurement of heart-beat and respiration periods using a phonocardiographic sensor, Med. Biol. Eng. Comput., 2002, 40, 246-252
    • (2002) Med. Biol. Eng. Comput , vol.40 , pp. 246-252
    • Tanaka, S.1    Matsumoto, Y.2    Wakimoto, K.3
  • 14
    • 77949788075 scopus 로고    scopus 로고
    • Daubechies I. Ten lecture on wavelets. Philadelphia: SIAM, 00. 279, 1992.
    • Daubechies I. Ten lecture on wavelets. Philadelphia: SIAM, 00. 279, 1992.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.