메뉴 건너뛰기




Volumn 43, Issue 6, 2005, Pages 716-724

Unconstrained cardiorespiratory and body movement monitoring system for home care

Author keywords

Automated system; Cardiorespiratory signals; Posture change; PVDF; Vital sign

Indexed keywords

AUTOMATED SYSTEM; CARDIORESPIRATORY SIGNALS; POSTURE CHANGE; PVDF; VITAL SIGN;

EID: 33750718482     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02430948     Document Type: Article
Times cited : (51)

References (18)
  • 1
    • 0019568381 scopus 로고
    • 'A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration'
    • Alihanka, J., Vaahtoranta, K., and Saarikivi, I. (1981): 'A new method for long-term monitoring of the ballistocardiogram, heart rate, and respiration,' Am. J. Physiol., 240, pp. R384-R392
    • (1981) Am. J. Physiol. , vol.240
    • Alihanka, J.1    Vaahtoranta, K.2    Saarikivi, I.3
  • 2
    • 0027359450 scopus 로고
    • 'A transducer for detecting foetal breathing movements using PVDF film'
    • Ansourian, M.N., Dripps, J.H., Jordan, J.R., Beattie, G.J., and Boddy, K. (1993): 'A transducer for detecting foetal breathing movements using PVDF film,' Physiol. Meas., 14, pp. 365-372
    • (1993) Physiol. Meas. , vol.14 , pp. 365-372
    • Ansourian, M.N.1    Dripps, J.H.2    Jordan, J.R.3    Beattie, G.J.4    Boddy, K.5
  • 3
    • 20044394397 scopus 로고    scopus 로고
    • 'Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements'
    • Chee, Y., Han, J., Youn, J., and Park, K. (2005): 'Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements,' Physiol. Meas., 26, pp. 413-422
    • (2005) Physiol. Meas. , vol.26 , pp. 413-422
    • Chee, Y.1    Han, J.2    Youn, J.3    Park, K.4
  • 4
    • 18144408065 scopus 로고    scopus 로고
    • 'Unconstrained detection of respiration rhythm and pulse rate with one under-pillow sensor during sleep'
    • Chen, W., Zhu, X., Nemoto, T., Kanemitsu, Y., Kitamura, K., and Yamakoshi, K. (2005): 'Unconstrained detection of respiration rhythm and pulse rate with one under-pillow sensor during sleep,' Med. Biol. Eng. Comput., 43, pp. 306-312
    • (2005) Med. Biol. Eng. Comput. , vol.43 , pp. 306-312
    • Chen, W.1    Zhu, X.2    Nemoto, T.3    Kanemitsu, Y.4    Kitamura, K.5    Yamakoshi, K.6
  • 5
    • 0025915141 scopus 로고
    • 'AURA: A new respiratory monitor and apnoea alarm for spontaneously breathing patients'
    • Cyna, A.M., Kulkarni, V., Tunstall, M.E., Hutchison, J.M.S., and Mallard, J.R. (1991): 'AURA: A new respiratory monitor and apnoea alarm for spontaneously breathing patients,' Br. J. Anaesth., 67, pp. 341-345
    • (1991) Br. J. Anaesth. , vol.67 , pp. 341-345
    • Cyna, A.M.1    Kulkarni, V.2    Tunstall, M.E.3    Hutchison, J.M.S.4    Mallard, J.R.5
  • 6
    • 0023984851 scopus 로고
    • 'Application of piezo/pyroelectric films in medical transducers'
    • Fraden, J. (1988): 'Application of piezo/pyroelectric films in medical transducers,' J. Clin. Eng., 13, pp. 133-138
    • (1988) J. Clin. Eng. , vol.13 , pp. 133-138
    • Fraden, J.1
  • 7
    • 0029033327 scopus 로고
    • 'A new non-invasive approach for monitoring respiratory movements of sleeping subjects'
    • Hernandez, L., Waag, B., Hsiao, H., and Neelon, V. (1995): 'A new non-invasive approach for monitoring respiratory movements of sleeping subjects,' Physiol. Meas., 16, pp. 161-167
    • (1995) Physiol. Meas. , vol.16 , pp. 161-167
    • Hernandez, L.1    Waag, B.2    Hsiao, H.3    Neelon, V.4
  • 8
    • 0031281910 scopus 로고    scopus 로고
    • 'Cardiopulmonary monitoring by textile electrodes without subject awareness of being monitored'
    • Ishijima, M. (1997): 'Cardiopulmonary monitoring by textile electrodes without subject awareness of being monitored,' Med. Biol. Eng. Comput., 35, pp. 685-690
    • (1997) Med. Biol. Eng. Comput. , vol.35 , pp. 685-690
    • Ishijima, M.1
  • 9
    • 0742303088 scopus 로고    scopus 로고
    • 'Design of filter to reject motion artifact of pulse oximetry'
    • Lee, J., Jung, W., Kang, I., Kim, Y., and Lee, G. (2004): 'Design of filter to reject motion artifact of pulse oximetry,' Comp. Stand. Inter., 26, pp. 241-249
    • (2004) Comp. Stand. Inter. , vol.26 , pp. 241-249
    • Lee, J.1    Jung, W.2    Kang, I.3    Kim, Y.4    Lee, G.5
  • 10
    • 0026674358 scopus 로고
    • 'Monitoring of respiratory and heart rates using a fibre-optic sensor'
    • Lindberg, L.G., Ugnell, H., and Oberg, P.A. (1992): 'Monitoring of respiratory and heart rates using a fibre-optic sensor,' Med. Biol. Eng. Comput., 30, pp. 533-537
    • (1992) Med. Biol. Eng. Comput. , vol.30 , pp. 533-537
    • Lindberg, L.G.1    Ugnell, H.2    Oberg, P.A.3
  • 11
    • 0042553279 scopus 로고
    • 'Smoothing and differentiation of data by simplified least squares procedures'
    • Savitzky, A. and Golay, M.J.E. (1964): 'Smoothing and differentiation of data by simplified least squares procedures,' Analyt. Chem., 36, pp. 1627-1639
    • (1964) Analyt. Chem. , vol.36 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.J.E.2
  • 12
    • 0024691045 scopus 로고
    • 'New noninvasive piezoelectric transducer for recording of respiration, heart rate and body movements'
    • Siivola, J. (1989): 'New noninvasive piezoelectric transducer for recording of respiration, heart rate and body movements', Med. Biol. Eng. Comput., 27, pp. 423-424
    • (1989) Med. Biol. Eng. Comput. , vol.27 , pp. 423-424
    • Siivola, J.1
  • 13
    • 0036261771 scopus 로고    scopus 로고
    • 'Unconstrained and non-invasive measurement of heart-beat and respiration periods using a phonocardiographic sensor'
    • Tanaka, S., Matsumoto, Y., and Wakimoto, K. (2002): 'Unconstrained and non-invasive measurement of heart-beat and respiration periods using a phonocardiographic sensor,' Med. Biol. Eng., Comput., 40, pp. 246-252
    • (2002) Med. Biol. Eng., Comput. , vol.40 , pp. 246-252
    • Tanaka, S.1    Matsumoto, Y.2    Wakimoto, K.3
  • 14
    • 0027470191 scopus 로고
    • 'Simple, noninvasive system for measuring the heart rate of avian embryos and hatchlings by means of a piezoelectric film'
    • Tazawa, H., Hashimoto, Y., Takami, M., Yufu, Y., and Whittow, G.C. (1993): 'Simple, noninvasive system for measuring the heart rate of avian embryos and hatchlings by means of a piezoelectric film,' Med. Biol. Eng. Comput., 31, pp. 129-134
    • (1993) Med. Biol. Eng. Comput. , vol.31 , pp. 129-134
    • Tazawa, H.1    Hashimoto, Y.2    Takami, M.3    Yufu, Y.4    Whittow, G.C.5
  • 16
    • 84945931130 scopus 로고    scopus 로고
    • 'An approach for extractions of pulse and respiration information from pulsatile pressure signals'
    • Keihanna, Japan 019266-1
    • Uchida, M., Ding, S., Chen, W., Nemoto, T., and Wei, D. (2003): 'An approach for extractions of pulse and respiration information from pulsatile pressure signals'. Proc. Int. Conf. APBME, Keihanna, Japan, 019266-1
    • (2003) Proc. Int. Conf. APBME
    • Uchida, M.1    Ding, S.2    Chen, W.3    Nemoto, T.4    Wei, D.5
  • 17
    • 0041847302 scopus 로고    scopus 로고
    • 'Development of a PVDF piezopolymer sensor for unconstrained in-sleep cardio-respiratory monitoring'
    • Wang, F., Tanaka, M., and Chonan, S. (2003): 'Development of a PVDF piezopolymer sensor for unconstrained in-sleep cardio-respiratory monitoring,' J. Intel. Mat. Syst. Str., 14, pp. 185-190
    • (2003) J. Intel. Mat. Syst. Str. , vol.14 , pp. 185-190
    • Wang, F.1    Tanaka, M.2    Chonan, S.3
  • 18
    • 0027653606 scopus 로고
    • 'Development of a piezopolymer pressure sensor for a portable fetal heart rate monitor'
    • Zuckerwar, A.J., Pretlow, R.A., Stoughton, J.W., and Baker, D.A. (1993): 'Development of a piezopolymer pressure sensor for a portable fetal heart rate monitor,' IEEE Trans. Biomed. Eng., 40, pp. 963-969
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , pp. 963-969
    • Zuckerwar, A.J.1    Pretlow, R.A.2    Stoughton, J.W.3    Baker, D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.