메뉴 건너뛰기




Volumn 19, Issue 2, 2010, Pages 155-160

Maternal haemodynamics at elective caesarean section: a randomised comparison of oxytocin 5-unit bolus and placebo infusion with oxytocin 5-unit bolus and 30-unit infusion

Author keywords

Bioimpedance; Caesarean section; Maternal haemodynamics; Oxytocin

Indexed keywords

OXYTOCIN;

EID: 77949774658     PISSN: 0959289X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijoa.2009.08.005     Document Type: Article
Times cited : (22)

References (14)
  • 1
    • 52249089407 scopus 로고    scopus 로고
    • The hemodynamics of oxytocin and other vasoactive agents during neuraxial anesthesia for cesarean delivery: findings in six cases
    • Archer T.L., Knape K., Liles D., Wheeler A.S., and Carter B. The hemodynamics of oxytocin and other vasoactive agents during neuraxial anesthesia for cesarean delivery: findings in six cases. Int J Obstet Anesth 17 (2008) 247-254
    • (2008) Int J Obstet Anesth , vol.17 , pp. 247-254
    • Archer, T.L.1    Knape, K.2    Liles, D.3    Wheeler, A.S.4    Carter, B.5
  • 2
    • 43249112286 scopus 로고    scopus 로고
    • Signs of myocardial ischaemia after injection of oxytocin: a randomized double-blind comparison of oxytocin and methylergometrine during Caesarean section
    • Svanstrom M.C., Biber B., Hanes M., Johansson G., Naslund U., and Balfors E.M. Signs of myocardial ischaemia after injection of oxytocin: a randomized double-blind comparison of oxytocin and methylergometrine during Caesarean section. Br J Anaesth 100 (2008) 683-689
    • (2008) Br J Anaesth , vol.100 , pp. 683-689
    • Svanstrom, M.C.1    Biber, B.2    Hanes, M.3    Johansson, G.4    Naslund, U.5    Balfors, E.M.6
  • 4
    • 0037340196 scopus 로고    scopus 로고
    • Effect of the confidential enquiries into maternal deaths on the use of Syntocinon at Caesarean section in the UK
    • Bolton T.J., Randall K., and Yentis S.M. Effect of the confidential enquiries into maternal deaths on the use of Syntocinon at Caesarean section in the UK. Anaesthesia 58 (2003) 277-279
    • (2003) Anaesthesia , vol.58 , pp. 277-279
    • Bolton, T.J.1    Randall, K.2    Yentis, S.M.3
  • 5
    • 33845395807 scopus 로고    scopus 로고
    • Haemodynamic effects of oxytocin given as i.v. bolus or infusion on women undergoing Caesarean section
    • Thomas J.S., Koh S.H., and Cooper G.M. Haemodynamic effects of oxytocin given as i.v. bolus or infusion on women undergoing Caesarean section. Br J Anaesth 98 (2007) 116-119
    • (2007) Br J Anaesth , vol.98 , pp. 116-119
    • Thomas, J.S.1    Koh, S.H.2    Cooper, G.M.3
  • 6
    • 56449120585 scopus 로고    scopus 로고
    • Intravenous oxytocin bolus of 2 units is superior to 5 units during elective Caesarean section
    • Sartain J.B., Barry J.J., Howat P.W., McCormack D.I., and Bryan M. Intravenous oxytocin bolus of 2 units is superior to 5 units during elective Caesarean section. Br J Anaesth 101 (2008) 822-826
    • (2008) Br J Anaesth , vol.101 , pp. 822-826
    • Sartain, J.B.1    Barry, J.J.2    Howat, P.W.3    McCormack, D.I.4    Bryan, M.5
  • 9
    • 57649098244 scopus 로고    scopus 로고
    • A randomised controlled trial of oxytocin 5IU and placebo infusion versus oxytocin 5IU and 30IU infusion for the control of blood loss at elective caesarean section-Pilot study. ISRCTN 40302163
    • Murphy D.J., MacGregor H., Munishankar B., and McLeod G. A randomised controlled trial of oxytocin 5IU and placebo infusion versus oxytocin 5IU and 30IU infusion for the control of blood loss at elective caesarean section-Pilot study. ISRCTN 40302163. Eur J Obstet Gynecol Reprod Biol 142 (2009) 30-33
    • (2009) Eur J Obstet Gynecol Reprod Biol , vol.142 , pp. 30-33
    • Murphy, D.J.1    MacGregor, H.2    Munishankar, B.3    McLeod, G.4
  • 10
    • 1842536910 scopus 로고    scopus 로고
    • Comparison of phenylephrine infusion regimens for maintaining maternal blood pressure during spinal anaesthesia for Caesarean section
    • Ngan Kee W.D., Khaw K.S., and Ng F.F. Comparison of phenylephrine infusion regimens for maintaining maternal blood pressure during spinal anaesthesia for Caesarean section. Br J Anaesth 92 (2004) 469-474
    • (2004) Br J Anaesth , vol.92 , pp. 469-474
    • Ngan Kee, W.D.1    Khaw, K.S.2    Ng, F.F.3
  • 11
    • 1842559774 scopus 로고    scopus 로고
    • Spinal anaesthesia for Caesarean delivery: keep the pressure up and don't spare the vasoconstrictors
    • Riley E.T. Spinal anaesthesia for Caesarean delivery: keep the pressure up and don't spare the vasoconstrictors. Br J Anaesth 92 (2004) 459-460
    • (2004) Br J Anaesth , vol.92 , pp. 459-460
    • Riley, E.T.1
  • 12
    • 0027958366 scopus 로고
    • Haemodynamic changes during epidural caesarean delivery
    • Wennberg E., and Frid I. Haemodynamic changes during epidural caesarean delivery. Int J Obstet Anesth 3 (1994) 16-19
    • (1994) Int J Obstet Anesth , vol.3 , pp. 16-19
    • Wennberg, E.1    Frid, I.2
  • 13
    • 0036323559 scopus 로고    scopus 로고
    • Haemodynamic changes caused by oxytocin during caesarean section under spinal anaesthesia
    • Pinder A.J., Dresner M., Calow C., O'Riordan J., and Johnson R. Haemodynamic changes caused by oxytocin during caesarean section under spinal anaesthesia. Int J Obstet Anesth 11 (2002) 156-159
    • (2002) Int J Obstet Anesth , vol.11 , pp. 156-159
    • Pinder, A.J.1    Dresner, M.2    Calow, C.3    O'Riordan, J.4    Johnson, R.5
  • 14
    • 2442688872 scopus 로고    scopus 로고
    • Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications
    • Moshkovitz Y., Kaluski E., Milo O., Vered Z., and Cotter G. Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and potential cardiovascular applications. Curr Opin Cardiol 19 (2004) 229-237
    • (2004) Curr Opin Cardiol , vol.19 , pp. 229-237
    • Moshkovitz, Y.1    Kaluski, E.2    Milo, O.3    Vered, Z.4    Cotter, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.