-
1
-
-
0023962312
-
A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery
-
Y. Kwoh, J. Hou, E. Jonckheere and S. Hayati, "A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery," IEEE Trans. Biomed. Eng. 35(2), 153-160 (1988).
-
(1988)
IEEE Trans. Biomed. Eng.
, vol.35
, Issue.2
, pp. 153-160
-
-
Kwoh, Y.1
Hou, J.2
Jonckheere, E.3
Hayati, S.4
-
2
-
-
33947319556
-
Total hip replacement - Robotic assisted technique
-
(A. DiGioia, ed.) (Oxford University Press)
-
A. Bauer, "Total hip replacement - robotic assisted technique," In: Computer and Robotic Assisted Knee and Hip Surgery (A. DiGioia, ed.) (Oxford University Press, 2004) pp. 83-96.
-
(2004)
Computer and Robotic Assisted Knee and Hip Surgery
, pp. 83-96
-
-
Bauer, A.1
-
3
-
-
0035996638
-
Technique and first clinical results of robot-assisted total knee replacement
-
W. Siebert, S. Mai, R. Kober and P. F. Heeckt, "Technique and first clinical results of robot-assisted total knee replacement," Knee, 9(3), 173-180 (2002).
-
(2002)
Knee
, vol.9
, Issue.3
, pp. 173-180
-
-
Siebert, W.1
Mai, S.2
Kober, R.3
Heeckt, P.F.4
-
4
-
-
33947434603
-
Total knee replacement: Robot-assistive technique
-
(A. DiGioia, ed.) (Oxford University Press)
-
W. Siebert, S. Mai, R. Kober and P. Heeckt, "Total knee replacement: Robot-assistive technique," In: Computer and Robotic Assisted Knee and Hip Surgery (A. DiGioia, ed.) (Oxford University Press, 2000) pp. 122-135.
-
(2000)
Computer and Robotic Assisted Knee and Hip Surgery
, pp. 122-135
-
-
Siebert, W.1
Mai, S.2
Kober, R.3
Heeckt, P.4
-
5
-
-
33947411198
-
Robotic control in knee joint replacement surgery
-
B. L. Davies, F. Rodriguez y Baena, A. R. W. Barrett, M. P. S. F. Gomes, S. J. Harris, M. Jakopec and J. P. Cobb, "Robotic control in knee joint replacement surgery," Proc. Inst. Mech. Eng. H, J. Eng. Med. 221, 71-80 (2007).
-
(2007)
Proc. Inst. Mech. Eng. H, J. Eng. Med.
, vol.221
, pp. 71-80
-
-
Davies, B.L.1
Rodriguez Y Baena, F.2
Barrett, A.R.W.3
Gomes, M.P.S.F.4
Harris, S.J.5
Jakopec, M.6
Cobb, J.P.7
-
7
-
-
0030629688
-
The Probot - An active robot for prostate resection
-
S. J. Harris, F. Arambula-Cosio, Q. Mei, R. D. Hibberd, B. L. Davies, J. E. A. Wickham, M. S. Nathan and B. Kundu, "The Probot - an active robot for prostate resection," Proc. Inst. Mech. Eng. H, J. Eng. Med. 211(4), 317-326 (1997).
-
(1997)
Proc. Inst. Mech. Eng. H, J. Eng. Med.
, vol.211
, Issue.4
, pp. 317-326
-
-
Harris, S.J.1
Arambula-Cosio, F.2
Mei, Q.3
Hibberd, R.D.4
Davies, B.L.5
Wickham, J.E.A.6
Nathan, M.S.7
Kundu, B.8
-
8
-
-
0035735799
-
The first clinical application of a 'hands-on' robotic knee surgery system
-
M. Jakopec, S. Harris, F. M. Rodriguez y Baena, P. Gomes, J. Cobb and B. Davies, "The first clinical application of a 'hands-on' robotic knee surgery system," Comp. Aid. Surg. 6(6), 329-339 (2001).
-
(2001)
Comp. Aid. Surg.
, vol.6
, Issue.6
, pp. 329-339
-
-
Jakopec, M.1
Harris, S.2
Rodriguez Y Baena, F.M.3
Gomes, P.4
Cobb, J.5
Davies, B.6
-
9
-
-
0142196054
-
The hands-on orthopaedic robot 'Acrobot': Early clinical trials of total knee replacement surgery
-
M. Jakopec, F. M. Rodriguez y Baena, S. J. Harris, P. Gomes, J. Cobb and B. L. Davies, "The hands-on orthopaedic robot 'Acrobot': Early clinical trials of total knee replacement surgery," IEEE Trans. Rob. Automat. 19(5), 902-911 (2003).
-
(2003)
IEEE Trans. Rob. Automat.
, vol.19
, Issue.5
, pp. 902-911
-
-
Jakopec, M.1
Rodriguez Y Baena, F.M.2
Harris, S.J.3
Gomes, P.4
Cobb, J.5
Davies, B.L.6
-
10
-
-
33244496943
-
Hands-on robotic unicompartmental knee replacement
-
J. Cobb, J. Henckel, P. Gomes, S. Harris, M. Jakopec, F. Rodriguez y Baena, A. Barrett and B. Davies, "Hands-on robotic unicompartmental knee replacement," J. Bone Joint Surg. 88, 188-197 (2006).
-
(2006)
J. Bone Joint Surg.
, vol.88
, pp. 188-197
-
-
Cobb, J.1
Henckel, J.2
Gomes, P.3
Harris, S.4
Jakopec, M.5
Rodriguez Y Baena, F.6
Barrett, A.7
Davies, B.8
-
11
-
-
0033724356
-
The Intuitive telesurgery system: Overview and application
-
G. S. Guthart and J. K. Salisbury, "The Intuitive telesurgery system: Overview and application," IEEE Int. Conf. Rob. Automat. 1, 618-4102 (2000).
-
(2000)
IEEE Int. Conf. Rob. Automat.
, vol.1
, pp. 618-4102
-
-
Guthart, G.S.1
Salisbury, J.K.2
-
12
-
-
33751243584
-
Very low-dose computed tomography for planning and outcome measurement in knee replacement
-
J. Henckel, R. Richards, K. Lozhkin, S. Harris, F. M. Rodriguez y Baena, A. R. W. Barrett and J. P. Cobb, "Very low-dose computed tomography for planning and outcome measurement in knee replacement," J. Bone Joint Surg. 88, 1513-1518 (2006).
-
(2006)
J. Bone Joint Surg.
, vol.88
, pp. 1513-1518
-
-
Henckel, J.1
Richards, R.2
Lozhkin, K.3
Harris, S.4
Rodriguez Y Baena, F.M.5
Barrett, A.R.W.6
Cobb, J.P.7
-
13
-
-
35948979654
-
Computer-assisted hip resurfacing surgery using the Acrobot navigation system
-
A. R.W. Barrett, B. L.Davies, M. P. S. F. Gomes, S. J. Harris, J. Henckel, M. Jakopec, V. Kannan, F. M. Rodriguez y Baena and J. P. Cobb, "Computer-assisted hip resurfacing surgery using the Acrobot navigation system," Proc. Inst. Mech. Eng. H, J. Eng. Med. 221, 773-786 (2007).
-
(2007)
Proc. Inst. Mech. Eng. H, J. Eng. Med.
, vol.221
, pp. 773-786
-
-
Barrett, A.R.W.1
Davies, B.L.2
Gomes, M.P.S.F.3
Harris, S.J.4
Henckel, J.5
Jakopec, M.6
Kannan, V.7
Rodriguez Y Baena, F.M.8
Cobb, J.P.9
-
14
-
-
33846321900
-
Preoperative planning and intraoperative guidance for accurate computer-assisted minimally invasive hip resurfacing surgery
-
A. R.W. Barrett, B. L.Davies, M. P. S. F. Gomes, S. J. Harris, J. Henckel, M. Jakopec, F. M. Rodriguez y Baena and J. P. Cobb, "Preoperative planning and intraoperative guidance for accurate computer-assisted minimally invasive hip resurfacing surgery," Proc. Inst. Mech. Eng. H, J. Eng. Med. 220, 759-774 (2006).
-
(2006)
Proc. Inst. Mech. Eng. H, J. Eng. Med.
, vol.220
, pp. 759-774
-
-
Barrett, A.R.W.1
Davies, B.L.2
Gomes, M.P.S.F.3
Harris, S.J.4
Henckel, J.5
Jakopec, M.6
Rodriguez Y Baena, F.M.7
Cobb, J.P.8
-
15
-
-
0032008619
-
A survey of medical image registration
-
J. Maintz and M. Viergever, "A survey of medical image registration," Med. Image Anal. 2(1), 1-36 (1998).
-
(1998)
Med. Image Anal.
, vol.2
, Issue.1
, pp. 1-36
-
-
Maintz, J.1
Viergever, M.2
-
16
-
-
0029793771
-
Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration
-
R. E. Ellis, S. Toksvig-Larsen, M. Marcacci, D. Caramella, and M. Fadda, "Use of a biocompatible fiducial marker in evaluating the accuracy of computed tomography image registration," Invest. Radiol. 31(10), 658-667 (1996).
-
(1996)
Invest. Radiol.
, vol.31
, Issue.10
, pp. 658-667
-
-
Ellis, R.E.1
Toksvig-Larsen, S.2
Marcacci, M.3
Caramella, D.4
Fadda, M.5
-
17
-
-
0032944269
-
Validation of a functional method for the estimation of hip joint centre location
-
A. Leardini, "Validation of a functional method for the estimation of hip joint centre location," J. Biomech. 32(1), 99 (1999).
-
(1999)
J. Biomech.
, vol.32
, Issue.1
, pp. 99
-
-
Leardini, A.1
-
18
-
-
85117704911
-
Accurate simulation of hip joint range of motion
-
K. MyungJin, H. Sadri, L. Moccozet, N. Magnenat-Thalmann and P. Hoffmeyer, "Accurate simulation of hip joint range of motion," In: Computer Animation, 2002. Proceedings (2002) pp. 215-219.
-
(2002)
Computer Animation, 2002. Proceedings
, pp. 215-219
-
-
Myung Jin, K.1
Sadri, H.2
Moccozet, L.3
Magnenat-Thalmann, N.4
Hoffmeyer, P.5
|