1
-
-
27744599403
-
A hip wear simulator with 100 test stations
-
DOI: 10.1243/095441105X34301
-
Saikko, V. A hip wear simulator with 100 test stations. Proc. IMechE, Part H: J. Engineering in Medicine, 2005, 219(H5), 309-318. DOI: 10.1243/095441105X34301.
-
(2005)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.219
, Issue.H5
, pp. 309-318
-
-
Saikko, V.1
-
2
-
-
0038546396
-
Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene
-
Mazzucco, D. and Spector, M. Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene.Wear, 2003, 254, 514-522.
-
(2003)
Wear
, vol.254
, pp. 514-522
-
-
Mazzucco, D.1
Spector, M.2
-
3
-
-
19944371380
-
The effect of counterface roughness on thewear ofUHMWPE for rectangularwear paths
-
Turell, M. E., Friedlaender, G. E., Wang, A., Thornhill, T. S., and Bellare, A. The effect of counterface roughness on thewear ofUHMWPE for rectangularwear paths. Wear, 2005, 259, 984-991.
-
(2005)
Wear
, vol.259
, pp. 984-991
-
-
Turell, M.E.1
Friedlaender, G.E.2
Wang, A.3
Thornhill, T.S.4
Bellare, A.5
-
4
-
-
42949141700
-
Synthesis and mechanicalwear studies of ultra smooth nanostructured diamond (USND) coatings deposited by microwave plasma chemical vapor deposition with He/H2/CH4/N2 mixtures
-
Chowdhury, S., Borham, J., Catledge, S. A., Eberhardt, A. W., Johnson, P. S., and Vohra, Y. K. Synthesis and mechanicalwear studies of ultra smooth nanostructured diamond (USND) coatings deposited by microwave plasma chemical vapor deposition with He/H2/CH4/N2 mixtures. Diam. Relat.Mater., 2008, 17, 419-427.
-
(2008)
Diam. Relat.Mater.
, vol.17
, pp. 419-427
-
-
Chowdhury, S.1
Borham, J.2
Catledge, S.A.3
Eberhardt, A.W.4
Johnson, P.S.5
Vohra, Y.K.6
-
5
-
-
0032775639
-
Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
-
Kurtz, S. M., Muratoglu, O. K., Evans, M., and Edidin, A. A. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials, 1999, 20, 1659-1688.
-
(1999)
Biomaterials
, vol.20
, pp. 1659-1688
-
-
Kurtz, S.M.1
Muratoglu, O.K.2
Evans, M.3
Edidin, A.A.4
-
6
-
-
18244404013
-
Polyethylene wear rate and osteolysis: Critical threshold versus continuous dose-response relationship
-
Wilkinson, J. M.,Hamer,A. J., Stockley, I., and Eastell, R. Polyethylene wear rate and osteolysis: critical threshold versus continuous dose-response relationship. J.Orthop. Res., 2005, 23, 520-525.
-
(2005)
J.Orthop. Res.
, vol.23
, pp. 520-525
-
-
Wilkinson, J.M.1
Hamer, A.J.2
Stockley, I.3
Eastell, R.4
-
7
-
-
44349089649
-
Wear in conventional and highly cross-linked polyethylene cups. A 5-year follow-up study
-
Olyslaegers, C., Defoort, K., Simon, J.-P., and Vandenberghe, L.Wear in conventional and highly cross-linked polyethylene cups. A 5-year follow-up study. J. Arthroplasty, 2008, 23, 489-494.
-
(2008)
J. Arthroplasty
, vol.23
, pp. 489-494
-
-
Olyslaegers, C.1
Defoort, K.2
Simon, J.-P.3
Vandenberghe, L.4
-
8
-
-
51049108385
-
Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty. A sonographic and radiographic study of 39 patients
-
Tarasevicius, S., Robertsson, O., Kesteris, U., Kalesinskas, R. J., and Wingstrand, H. Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty. A sonographic and radiographic study of 39 patients. Acta Orthop., 2008, 79, 489-493.
-
(2008)
Acta Orthop.
, vol.79
, pp. 489-493
-
-
Tarasevicius, S.1
Robertsson, O.2
Kesteris, U.3
Kalesinskas, R.J.4
Wingstrand, H.5
|