Volumn 21, Issue 4, 2010, Pages 470-476

Endovascular Management of Inadvertent Subclavian Artery Catheterization during Subclavian Vein Cannulation

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; HEPARIN;

EID: 77949659781     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvir.2009.12.392     Document Type: Article
Times cited : (27)

References (33)
  • 1
    • 0028085655 scopus 로고
    • The role of sonography in the placement and management of jugular and subclavian central venous catheters
    • Skolnick M.L. The role of sonography in the placement and management of jugular and subclavian central venous catheters. AJR Am J Roentgenol 163 (1994) 291-295
    • (1994) AJR Am J Roentgenol , vol.163 , pp. 291-295
    • Skolnick, M.L.1
  • 3
    • 38749149570 scopus 로고    scopus 로고
    • US-guided placement of central vein catheters in patients with disorders of hemostasis
    • Tercan F., Ozkan U., and Oguzkurt L. US-guided placement of central vein catheters in patients with disorders of hemostasis. Eur J Radiol 65 (2008) 253-256
    • (2008) Eur J Radiol , vol.65 , pp. 253-256
    • Tercan, F.1    Ozkan, U.2    Oguzkurt, L.3
  • 4
    • 70350121947 scopus 로고    scopus 로고
    • Randomized clinical trial comparing venous cutdown with the Seldinger technique for placement of implantable venous access ports
    • Nocito A., Wildi S., Rufibach K., Clavien P.A., and Weber M. Randomized clinical trial comparing venous cutdown with the Seldinger technique for placement of implantable venous access ports. Br J Surg 96 (2009) 1129-1134
    • (2009) Br J Surg , vol.96 , pp. 1129-1134
    • Nocito, A.1    Wildi, S.2    Rufibach, K.3    Clavien, P.A.4    Weber, M.5
  • 5
    • 1242319454 scopus 로고    scopus 로고
    • Managing inadvertent arterial catheterization during central venous access procedures
    • Nicholson T., Ettles D., and Robinson G. Managing inadvertent arterial catheterization during central venous access procedures. Cardiovasc Intervent Radiol 27 (2004) 21-25
    • (2004) Cardiovasc Intervent Radiol , vol.27 , pp. 21-25
    • Nicholson, T.1    Ettles, D.2    Robinson, G.3
  • 6
    • 0017787062 scopus 로고
    • Percutaneous catheter introduction: the Seldinger technique
    • Conahan III T.J., Schwartz A.J., and Geer R.T. Percutaneous catheter introduction: the Seldinger technique. JAMA 237 (1977) 446-447
    • (1977) JAMA , vol.237 , pp. 446-447
    • Conahan III, T.J.1    Schwartz, A.J.2    Geer, R.T.3
  • 7
    • 0002700555 scopus 로고    scopus 로고
    • Which is the easiest and safest technique for central venous access?. A retrospective survey of more than 5,400 cases
    • Pittiruti M., Malerba M., Carriero C., Tazza L., and Gui D. Which is the easiest and safest technique for central venous access?. A retrospective survey of more than 5,400 cases. J Vasc Access 1 (2000) 100-107
    • (2000) J Vasc Access , vol.1 , pp. 100-107
    • Pittiruti, M.1    Malerba, M.2    Carriero, C.3    Tazza, L.4    Gui, D.5
  • 9
    • 55149116097 scopus 로고    scopus 로고
    • Arterial trauma during central venous catheter insertion: case series, review and proposed algorithm
    • Guilbert M.C., Elkouri S., Bracco D., et al. Arterial trauma during central venous catheter insertion: case series, review and proposed algorithm. J Vasc Surg 48 (2008) 918-925
    • (2008) J Vasc Surg , vol.48 , pp. 918-925
    • Guilbert, M.C.1    Elkouri, S.2    Bracco, D.3
  • 10
    • 0037489790 scopus 로고    scopus 로고
    • Percutaneous arterial closure devices
    • Hoffer E.K., and Bloch R.D. Percutaneous arterial closure devices. J Vasc Interv Radiol 14 (2003) 865-885
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 865-885
    • Hoffer, E.K.1    Bloch, R.D.2
  • 11
    • 0034897864 scopus 로고    scopus 로고
    • Early clinical experience with the 6 French Angio-Seal device: immediate closure of femoral puncture sites after diagnostic and interventional coronary procedures
    • Eggebrecht H., Haude M., von B.C., Woertgen U., et al. Early clinical experience with the 6 French Angio-Seal device: immediate closure of femoral puncture sites after diagnostic and interventional coronary procedures. Cathet Cardiovasc Interv 53 (2001) 437-442
    • (2001) Cathet Cardiovasc Interv , vol.53 , pp. 437-442
    • Eggebrecht, H.1    Haude, M.2    von, B.C.3    Woertgen, U.4
  • 12
    • 0033233206 scopus 로고    scopus 로고
    • The Angio-Seal hemostatic puncture closure device. Concept and experimental results
    • Nash J.E., and Evans D.G. The Angio-Seal hemostatic puncture closure device. Concept and experimental results. Herz 24 (1999) 597-606
    • (1999) Herz , vol.24 , pp. 597-606
    • Nash, J.E.1    Evans, D.G.2
  • 13
    • 67651215988 scopus 로고    scopus 로고
    • Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion
    • Chemelli A.P., Chemelli-Steingruber I.E., Bonaros N., et al. Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion. Eur J Radiol 71 (2009) 269-274
    • (2009) Eur J Radiol , vol.71 , pp. 269-274
    • Chemelli, A.P.1    Chemelli-Steingruber, I.E.2    Bonaros, N.3
  • 14
    • 54049106079 scopus 로고    scopus 로고
    • Delayed treatment of a traumatic left subclavian artery pseudoaneurysm
    • Franz R.W. Delayed treatment of a traumatic left subclavian artery pseudoaneurysm. Vasc Endovascular Surg 42 (2008) 482-485
    • (2008) Vasc Endovascular Surg , vol.42 , pp. 482-485
    • Franz, R.W.1
  • 15
    • 0037674995 scopus 로고    scopus 로고
    • Elective and emergent endovascular treatment of subclavian artery aneurysms and injuries
    • Schoder M., Cejna M., Holzenbein T., et al. Elective and emergent endovascular treatment of subclavian artery aneurysms and injuries. J Endovasc Ther 10 (2003) 58-65
    • (2003) J Endovasc Ther , vol.10 , pp. 58-65
    • Schoder, M.1    Cejna, M.2    Holzenbein, T.3
  • 16
    • 0030832234 scopus 로고    scopus 로고
    • Complications of central venous catheter placement
    • Spies J.B., and Berlin L. Complications of central venous catheter placement. AJR Am J Roentgenol 169 (1997) 339-341
    • (1997) AJR Am J Roentgenol , vol.169 , pp. 339-341
    • Spies, J.B.1    Berlin, L.2
  • 17
    • 2942541223 scopus 로고    scopus 로고
    • Arterial misplacement of large-caliber cannulas during jugular vein catheterization: case for surgical management
    • Shah P.M., Babu S.C., Goyal A., Mateo R.B., and Madden R.E. Arterial misplacement of large-caliber cannulas during jugular vein catheterization: case for surgical management. J Am Coll Surg 198 (2004) 939-944
    • (2004) J Am Coll Surg , vol.198 , pp. 939-944
    • Shah, P.M.1    Babu, S.C.2    Goyal, A.3    Mateo, R.B.4    Madden, R.E.5
  • 19
    • 60649085135 scopus 로고    scopus 로고
    • Management of subclavian arterial injuries following inadvertent arterial puncture during central venous catheter placement
    • Abi-Jaoudeh N., Turba U.C., Arslan B., et al. Management of subclavian arterial injuries following inadvertent arterial puncture during central venous catheter placement. J Vasc Interv Radiol 20 (2009) 396-402
    • (2009) J Vasc Interv Radiol , vol.20 , pp. 396-402
    • Abi-Jaoudeh, N.1    Turba, U.C.2    Arslan, B.3
  • 20
    • 29144468148 scopus 로고    scopus 로고
    • Treatment of nonaortic aneurysms in the endograft era: aneurysms of the innominate and subclavian arteries
    • Chambers C.M., and Curci J.A. Treatment of nonaortic aneurysms in the endograft era: aneurysms of the innominate and subclavian arteries. Semin Vasc Surg 18 (2005) 184-190
    • (2005) Semin Vasc Surg , vol.18 , pp. 184-190
    • Chambers, C.M.1    Curci, J.A.2
  • 21
    • 3843121834 scopus 로고    scopus 로고
    • Use of a large angioplasty balloon for predilation is a risk factor for embolic complications in protected carotid stenting
    • Sadato A., Satow T., Ishii A., Ohta T., and Hashimoto N. Use of a large angioplasty balloon for predilation is a risk factor for embolic complications in protected carotid stenting. Neurol Med Chir (Tokyo) 44 (2004) 337-342
    • (2004) Neurol Med Chir (Tokyo) , vol.44 , pp. 337-342
    • Sadato, A.1    Satow, T.2    Ishii, A.3    Ohta, T.4    Hashimoto, N.5
  • 22
    • 41149122526 scopus 로고    scopus 로고
    • Long-term results of stent graft treatment of subclavian artery injuries: management of choice for stable patients?
    • du Toit D.F., Lambrechts A.V., Stark H., and Warren B.L. Long-term results of stent graft treatment of subclavian artery injuries: management of choice for stable patients?. J Vasc Surg 47 (2008) 739-743
    • (2008) J Vasc Surg , vol.47 , pp. 739-743
    • du Toit, D.F.1    Lambrechts, A.V.2    Stark, H.3    Warren, B.L.4
  • 23
    • 0033928564 scopus 로고    scopus 로고
    • Balloon tamponade for the treatment of inadvertent subclavian arterial catheter placement
    • Alexander J.R., Weeks S.M., Sandhu J., et al. Balloon tamponade for the treatment of inadvertent subclavian arterial catheter placement. J Vasc Interv Radiol 11 (2000) 875-877
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 875-877
    • Alexander, J.R.1    Weeks, S.M.2    Sandhu, J.3
  • 24
    • 54049132475 scopus 로고    scopus 로고
    • The use of arterial closure devices for incidental arterial injury
    • Kirkwood M.L., Wahlgren C.M., and Desai T.R. The use of arterial closure devices for incidental arterial injury. Vasc Endovascular Surg 42 (2008) 471-476
    • (2008) Vasc Endovascular Surg , vol.42 , pp. 471-476
    • Kirkwood, M.L.1    Wahlgren, C.M.2    Desai, T.R.3
  • 25
    • 0032909434 scopus 로고    scopus 로고
    • Use of a collagen plug device to seal a subclavian artery puncture secondary to intraarterial dialysis catheter placement
    • Dowling K., Herr A., Siskin G., Sansivero G.E., and Stainken B. Use of a collagen plug device to seal a subclavian artery puncture secondary to intraarterial dialysis catheter placement. J Vasc Interv Radiol 10 (1999) 33-35
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 33-35
    • Dowling, K.1    Herr, A.2    Siskin, G.3    Sansivero, G.E.4    Stainken, B.5
  • 26
    • 11244261264 scopus 로고    scopus 로고
    • The use of a collagen-based puncture closure device in the subclavian artery after inadvertent introduction of an 11.5 French hemodialysis catheter
    • Railo M., and Roth W.D. The use of a collagen-based puncture closure device in the subclavian artery after inadvertent introduction of an 11.5 French hemodialysis catheter. Cardiovasc Intervent Radiol 27 (2004) 681-682
    • (2004) Cardiovasc Intervent Radiol , vol.27 , pp. 681-682
    • Railo, M.1    Roth, W.D.2
  • 27
    • 45449105811 scopus 로고    scopus 로고
    • Complications associated with the arterial puncture closure device-Angio-Seal
    • Kadner A., Schmidli J., Schwegler I., et al. Complications associated with the arterial puncture closure device-Angio-Seal. Vasc Endovascular Surg 42 (2008) 225-227
    • (2008) Vasc Endovascular Surg , vol.42 , pp. 225-227
    • Kadner, A.1    Schmidli, J.2    Schwegler, I.3
  • 29
    • 34547096167 scopus 로고    scopus 로고
    • Complications associated with the Angio-Seal arterial puncture closing device: intra-arterial deployment and occlusion by dissected plaque
    • Dregelid E., Jensen G., and Daryapeyma A. Complications associated with the Angio-Seal arterial puncture closing device: intra-arterial deployment and occlusion by dissected plaque. J Vasc Surg 44 (2006) 1357-1359
    • (2006) J Vasc Surg , vol.44 , pp. 1357-1359
    • Dregelid, E.1    Jensen, G.2    Daryapeyma, A.3
  • 30
    • 0033385960 scopus 로고    scopus 로고
    • Surgical complications from hemostatic puncture closure devices
    • Eidt J.F., Habibipour S., Saucedo J.F., et al. Surgical complications from hemostatic puncture closure devices. Am J Surg 178 (1999) 511-516
    • (1999) Am J Surg , vol.178 , pp. 511-516
    • Eidt, J.F.1    Habibipour, S.2    Saucedo, J.F.3
  • 31
    • 0036852807 scopus 로고    scopus 로고
    • Late clinical presentation of femoral artery occlusion after deployment of the Angio-Seal closure device
    • Ferreira A.C., Eton D., and de Marchena E. Late clinical presentation of femoral artery occlusion after deployment of the Angio-Seal closure device. J Invas Cardiol 14 (2002) 689-691
    • (2002) J Invas Cardiol , vol.14 , pp. 689-691
    • Ferreira, A.C.1    Eton, D.2    de Marchena, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.