Editorial: Defibrillation threshold testing at implantation: Can we predict the patient with a high defibrillation threshold?

Author keywords

[No Author keywords available]

Indexed keywords

DEFIBRILLATION; DEFIBRILLATOR; EDITORIAL; HEART FAILURE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE MASS; HEART LEFT VENTRICLE VOLUME; HUMAN; IMPLANTATION; PRIORITY JOURNAL; RISK ASSESSMENT; SYSTOLE; CALIBRATION; HEART ARRHYTHMIA; NOTE; PREDICTION AND FORECASTING; STANDARD;

EID: 77749324868     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/euq003     Document Type: Editorial
Times cited : (4)

References (13)
  • 1
    • 3242794231 scopus 로고    scopus 로고
    • Is defibrillation testing required for defibrillator implantation?
    • Strickberger SA, Klein GJ. Is defibrillation testing required for defibrillator implantation? J Am Coll Cardiol 2004;44:88-91.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 88-91
    • Strickberger, S.A.1    Klein, G.J.2
  • 2
    • 20244387585 scopus 로고    scopus 로고
    • Defibrillation threshold testing: Is it really necessary at the time of implantable cardioverter-defibrillator insertion?
    • Russo AM, Sauer W, Gerstenfeld EP, Hsia HH, Lin D, Cooper JM et al. Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion? Heart Rhythm 2005;2:456-61.
    • (2005) Heart Rhythm , vol.2 , pp. 456-461
    • Russo, A.M.1    Sauer, W.2    Gerstenfeld, E.P.3    Hsia, H.H.4    Lin, D.5    Cooper, J.M.6
  • 4
    • 39649088013 scopus 로고    scopus 로고
    • Complications associated with defibrillation threshold testing: The Canadian experience
    • Birnie D, Tung S, Simpson C, Crystal E, Exner D, Ayala Paredes FA et al. Complications associated with defibrillation threshold testing: the Canadian experience. Heart Rhythm 2008;5:387-90.
    • (2008) Heart Rhythm , vol.5 , pp. 387-390
    • Birnie, D.1    Tung, S.2    Simpson, C.3    Crystal, E.4    Exner, D.5    Ayala Paredes, F.A.6
  • 7
    • 0030740114 scopus 로고    scopus 로고
    • Biphasic waveforms prevent the chronic rise of defibrillation thresholds with a transvenous lead system
    • Gold MR, Kavesh NG, Peters RW, Shorofsky SR. Biphasic waveforms prevent the chronic rise of defibrillation thresholds with a transvenous lead system. J Am Coll Cardiol 1997;30:233-6.
    • (1997) J Am Coll Cardiol , vol.30 , pp. 233-236
    • Gold, M.R.1    Kavesh, N.G.2    Peters, R.W.3    Shorofsky, S.R.4
  • 8
    • 0037197741 scopus 로고    scopus 로고
    • Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: Primary results from the Low Energy Safety Study (LESS)
    • Gold MR, Higgins S, Klein R, Gilliam FR, Kopelman H, Hessen S et al. Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS). Circulation 2002;105: 2043-8.
    • (2002) Circulation , vol.105 , pp. 2043-2048
    • Gold, M.R.1    Higgins, S.2    Klein, R.3    Gilliam, F.R.4    Kopelman, H.5    Hessen, S.6
  • 9
    • 0036231640 scopus 로고    scopus 로고
    • Clinical predictors of defibrillation thresholds with an active pectoral pulse generator lead system
    • Hodgson DM, Olsovsky MR, Shorofsky SR, Daly B, Gold MR. Clinical predictors of defibrillation thresholds with an active pectoral pulse generator lead system. Pacing Clin Electrophysiol 2002;25:408-13.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 408-413
    • Hodgson, D.M.1    Olsovsky, M.R.2    Shorofsky, S.R.3    Daly, B.4    Gold, M.R.5
  • 10
    • 0033390536 scopus 로고    scopus 로고
    • Multicenter evaluation of implantable cardioverter defibrillator testing after implant: The Post Implant Testing Study (PITS)
    • Brodsky CM, Chang F, Vlay SC. Multicenter evaluation of implantable cardioverter defibrillator testing after implant: the Post Implant Testing Study (PITS). Pacing Clin Electrophysiol 1999;22:1769-76.
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 1769-1776
    • Brodsky, C.M.1    Chang, F.2    Vlay, S.C.3
  • 11
    • 0029032493 scopus 로고
    • Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system
    • Raitt MH, Johnson G, Dolack GL, Poole JE, Kudenchuk PJ, Bardy GH. Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system. J Am Coll Cardiol 1995;25:1576- 83.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1576-1583
    • Raitt, M.H.1    Johnson, G.2    Dolack, G.L.3    Poole, J.E.4    Kudenchuk, P.J.5    Bardy, G.H.6
  • 13
    • 77749320077 scopus 로고    scopus 로고
    • Does defibrillation threshold increase as left ventricular ejection fraction decreases?
    • Val-Mejias JE, Oza A. Does defibrillation threshold increase as left ventricular ejection fraction decreases? Europace 2010;12:385-8.
    • Europace , vol.2010 , Issue.12 , pp. 385-388
    • Val-Mejias, J.E.1    Oza, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.