메뉴 건너뛰기




Volumn 82, Issue 5, 2010, Pages 2129-2133

Recommendations for fluorescence instrument qualification: The new ASTM standard guide

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTES; ASTM INTERNATIONAL; ASTM STANDARDS; DETECTION SYSTEM; FLUORESCENCE LIFETIMES; FLUORESCENCE MEASUREMENTS; FLUORESCENCE QUANTUM YIELD; FLUORESCENCE TECHNIQUE; INSTRUMENT CHARACTERIZATION; LIMIT OF DETECTION; PERFORMANCE VERIFICATION; SPECTRAL IRRADIANCE; SPECTRAL RESPONSIVITY; STEADY STATE; WAVELENGTH ACCURACY;

EID: 77749304908     PISSN: 00032700     EISSN: None     Source Type: Journal    
DOI: 10.1021/ac902507p     Document Type: Article
Times cited : (41)

References (60)
  • 10
    • 77749232911 scopus 로고    scopus 로고
    • NISTIR 7458; National Institute of Standards and Technology: Gaithersburg, MD, (submitted to ASTM for revision and publication).
    • DeRose, P. C. Standard Guide to Fluorescence-Instrument Calibration and Validation, NISTIR 7458; National Institute of Standards and Technology: Gaithersburg, MD, 2007 (submitted to ASTM for revision and publication).
    • (2007) Standard Guide to Fluorescence-Instrument Calibration and Validation
    • Derose, P.C.1
  • 11
    • 84942696736 scopus 로고    scopus 로고
    • Fluorescence Standards: Classification, Terminology and Recommendations On Their Selection, Use and Production. , in Press.
    • Resch-Genger, U.; DeRose, P. C. Fluorescence Standards: Classification, Terminology and Recommendations On Their Selection, Use and Production. Pure Appl. Chem., in press.
    • Pure Appl. Chem.
    • Resch-Genger, U.1    Derose, P.C.2
  • 12
    • 77749294114 scopus 로고    scopus 로고
    • IUPAC Project no.2004 021 1 300.
    • IUPAC Project no.2004 021 1 300.
  • 18
    • 84859980393 scopus 로고    scopus 로고
    • Standard test method for spectral bandwidth and wavelength accuracy of fluorescence spectrometers
    • ASTM E 388-04, 03.06 (original version 1972).
    • ASTM E 388-04, Standard Test Method for Spectral Bandwidth and Wavelength Accuracy of Fluorescence Spectrometers. In Annual book of ASTM standards; 2004; Vol 03.06 (original version 1972).
    • (2004) Annual Book of ASTM Standards
  • 19
    • 84982692550 scopus 로고    scopus 로고
    • Standard test method for linearity of fluorescence measuring systems
    • ASTM E 578-07, ASTM International: West Conshohocken, PA, 03.06 (original version 1983).
    • ASTM E 578-07, Standard Test Method for Linearity of Fluorescence Measuring Systems. In Annual book of ASTM standards; ASTM International: West Conshohocken, PA, 2007; Vol 03.06 (original version 1983).
    • (2007) Annual Book of ASTM Standards
  • 20
    • 84859980393 scopus 로고    scopus 로고
    • Standard test method for limit of detection of fluorescence of quinine sulfate
    • ASTM E 579-04, ASTM International: West Conshohocken, PA, 03.06 (original version 1984).
    • ASTM E 579-04, Standard Test Method for Limit of Detection of Fluorescence of Quinine Sulfate. In Annual book of ASTM standards; ASTM International: West Conshohocken, PA, 2004; Vol 03.06 (original version 1984).
    • (2004) Annual Book of ASTM Standards
  • 23
    • 77749232913 scopus 로고    scopus 로고
    • Standard guide for fluorescence-instrument calibration and validation
    • ASTM E 2719, ASTM International: West Conshohocken, PA, 03.06.
    • ASTM E 2719, Standard Guide for Fluorescence-Instrument Calibration and Validation. In Annual book of ASTM standards; ASTM International: West Conshohocken, PA, 2010; Vol. 03.06.
    • (2010) Annual Book of ASTM Standards
  • 33
    • 84864107318 scopus 로고    scopus 로고
    • Technical Note: Photon Technology International
    • Technical Note: The Measurement of Sensitivity in Fluorescence Spectroscopy; Photon Technology International, 2005; http://www.pti-nj.com/ products/Steady-State-Spectrofluorometei-/TechNotes/MeasurementSensitivity.pdf
    • (2005) The Measurement of Sensitivity in Fluorescence Spectroscopy
  • 48
    • 77749269530 scopus 로고    scopus 로고
    • Quantum counters are highly concentrated dye solutions that transform absorbed photons with an excitation wavelength-independent constant quantum yield into emitted photons. Such materials are prone to concentration, polarization, and geometry effects resulting in enhanced calibration uncertainties.
    • Quantum counters are highly concentrated dye solutions that transform absorbed photons with an excitation wavelength-independent constant quantum yield into emitted photons. Such materials are prone to concentration, polarization, and geometry effects resulting in enhanced calibration uncertainties.
  • 57
    • 77749300284 scopus 로고    scopus 로고
    • This includes an integrating sphere-based, instrument by Hamamatsu and integrating sphere-based accessories for Horiba Jobin Yvon and Edinburgh fluorometers.
    • This includes an integrating sphere-based, instrument by Hamamatsu and integrating sphere-based accessories for Horiba Jobin Yvon and Edinburgh fluorometers.
  • 58
    • 77749232907 scopus 로고    scopus 로고
    • Certain commercial equipment, instruments, or materials are identified in this paper to foster understanding. Such identification does not imply recommendation or endorsement by the National Institute of Standards and Technology or the Federal Institute for Standards and Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.
    • Certain commercial equipment, instruments, or materials are identified in this paper to foster understanding. Such identification does not imply recommendation or endorsement by the National Institute of Standards and Technology or the Federal Institute for Standards and Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose.