메뉴 건너뛰기




Volumn 41, Issue 5, 1999, Pages 964-972

Motion correction in fMRI via registration of individual slices into an anatomical volume

Author keywords

Echoplanar imaging; EPI; fMRI; Mapping; MI; Motion correction; Mutual information; Registration

Indexed keywords

MAGNETIC RESONANCE IMAGING; MANAGEMENT INFORMATION SYSTEMS; SIGNAL SYSTEMS;

EID: 0032900418     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199905)41:5<964::AID-MRM16>3.0.CO;2-D     Document Type: Article
Times cited : (116)

References (20)
  • 3
    • 0029118783 scopus 로고
    • Retrospective estimation and correction of physiological fluctuation in functional MRI
    • Hu X, Le TH, Parrish T, Erhard P. Retrospective estimation and correction of physiological fluctuation in functional MRI. Magn Reson Med 1995;34:201-212.
    • (1995) Magn Reson Med , vol.34 , pp. 201-212
    • Hu, X.1    Le, T.H.2    Parrish, T.3    Erhard, P.4
  • 5
    • 0030810112 scopus 로고    scopus 로고
    • Mutual information for automated unwarping of rat brain autoradiographs
    • Kim B, Boes JL, Frey KA, Meyer CR. Mutual information for automated unwarping of rat brain autoradiographs. Neuroimage 1997;5:31-40.
    • (1997) Neuroimage , vol.5 , pp. 31-40
    • Kim, B.1    Boes, J.L.2    Frey, K.A.3    Meyer, C.R.4
  • 6
    • 0031107387 scopus 로고    scopus 로고
    • Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin plate spline warped geometric deformations
    • Meyer CR, Boes JL, Kim B, Bland PH, Zasadny KR, Kison PV, Koral K, Frey KA, Wahl RL. Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin plate spline warped geometric deformations. Med Image Anal 1997;3:195-206.
    • (1997) Med Image Anal , vol.3 , pp. 195-206
    • Meyer, C.R.1    Boes, J.L.2    Kim, B.3    Bland, P.H.4    Zasadny, K.R.5    Kison, P.V.6    Koral, K.7    Frey, K.A.8    Wahl, R.L.9
  • 13
  • 15
    • 0344793870 scopus 로고    scopus 로고
    • Warping normal patients onto the ICBM atlas by maximizing MI
    • Meyer C, Boes JL, Kim B, Bland PH, Frey K. Warping normal patients onto the ICBM atlas by maximizing MI. Neuroimage 1998;7(4):S724.
    • (1998) Neuroimage , vol.7 , Issue.4
    • Meyer, C.1    Boes, J.L.2    Kim, B.3    Bland, P.H.4    Frey, K.5
  • 16
    • 0024657112 scopus 로고
    • Volumar imaging using NMR spin echoes: Echo-volumar imaging (EVI) at 0.1 T
    • Mansfield P, Howseman AM, Ordidge RJ. Volumar imaging using NMR spin echoes: echo-volumar imaging (EVI) at 0.1 T. J Phys E 1989;22:324-330.
    • (1989) J Phys E , vol.22 , pp. 324-330
    • Mansfield, P.1    Howseman, A.M.2    Ordidge, R.J.3
  • 19
    • 0029263826 scopus 로고
    • Retrospective correction of intensity inhomogeneities in MRI and CT
    • Meyer CR, Bland PH, Pipe J. Retrospective correction of intensity inhomogeneities in MRI and CT. IEEE Trans Med Img 1995;14:36-41.
    • (1995) IEEE Trans Med Img , vol.14 , pp. 36-41
    • Meyer, C.R.1    Bland, P.H.2    Pipe, J.3
  • 20


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.