메뉴 건너뛰기




Volumn 68, Issue 6, 2010, Pages 1040-1048

True coincidence-summing corrections for the coincident γ-rays measured with coplanar grid CdZnTe detectors

Author keywords

CdZnTe (CZT) detector; Coplanar grid (CPG); Disc source; Gamma ray; True coincidence summing (TCS)

Indexed keywords

CLOSE-IN; CO-PLANAR GRID; COINCIDENCE-SUMMING; COPLANAR GRIDS; COPLANAR-GRID CDZNTE DETECTORS; CORRECTION FACTORS; CRYSTAL VOLUME; CZT DETECTORS; DETECTION GEOMETRY; FULL ENERGY PEAK;

EID: 77649269971     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2010.01.042     Document Type: Article
Times cited : (7)

References (27)
  • 2
    • 0032669746 scopus 로고    scopus 로고
    • Gamma spectrometric characterization of various CdTe and CdZnTe detectors
    • Arlt R., Gryshchuk V., and Sumah P. Gamma spectrometric characterization of various CdTe and CdZnTe detectors. Nucl. Instrum. Methods A 428 (1999) 127-137
    • (1999) Nucl. Instrum. Methods A , vol.428 , pp. 127-137
    • Arlt, R.1    Gryshchuk, V.2    Sumah, P.3
  • 3
    • 33751078558 scopus 로고    scopus 로고
    • Calculation of coincidence summing corrections for X-ray peaks and for sum peaks with X-ray contributions
    • Arnold D., and Sima O. Calculation of coincidence summing corrections for X-ray peaks and for sum peaks with X-ray contributions. Appl. Radiat. Isot. 64 (2006) 1297-1302
    • (2006) Appl. Radiat. Isot. , vol.64 , pp. 1297-1302
    • Arnold, D.1    Sima, O.2
  • 6
    • 33746388795 scopus 로고    scopus 로고
    • An alternative approach for the determination of the full-peak detection efficiency in case of a close-in detection geometry
    • De Wispelaere A., and De Corte F. An alternative approach for the determination of the full-peak detection efficiency in case of a close-in detection geometry. Nucl. Instrum. Methods A 564 (2006) 645
    • (2006) Nucl. Instrum. Methods A , vol.564 , pp. 645
    • De Wispelaere, A.1    De Corte, F.2
  • 7
    • 58349100093 scopus 로고    scopus 로고
    • Tablefor true summation effect in gamma-ray spectrometry
    • also available in the web page: 〈http://www.cmi.cz/〉
    • Dryák P., and Kovar P. Tablefor true summation effect in gamma-ray spectrometry. J. Radioanal. Nucl. Chem. 279 2 (2009) 385-394. http://www.cmi.cz/ also available in the web page: 〈http://www.cmi.cz/〉
    • (2009) J. Radioanal. Nucl. Chem. , vol.279 , Issue.2 , pp. 385-394
    • Dryák, P.1    Kovar, P.2
  • 8
    • 0032673875 scopus 로고    scopus 로고
    • CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
    • Eisen Y., Shor A., and Mardor I. CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems. Nucl. Instrum. Methods A 428 (1999) 158-170
    • (1999) Nucl. Instrum. Methods A , vol.428 , pp. 158-170
    • Eisen, Y.1    Shor, A.2    Mardor, I.3
  • 9
    • 77649272536 scopus 로고    scopus 로고
    • EURACEM/CTAC Guide CG 4, 2000. Quantifying uncertainty in analytical measurement. Second ed., Geneva, Switzerland, ISBN:0-948926-15-5.
    • EURACEM/CTAC Guide CG 4, 2000. Quantifying uncertainty in analytical measurement. Second ed., Geneva, Switzerland, ISBN:0-948926-15-5.
  • 10
    • 77649273794 scopus 로고    scopus 로고
    • eV Products, 2009. A divison of II-VI Incorporated (Now: a division of Endicott Interconnect Technologies, Inc., 〈http://www.evmicroelectronics.com/〉), Saxonburg, PA 16056, semiconductor material properties on the web page: 〈http://www.evproducts.com〉 last accessed on June 2009.
    • eV Products, 2009. A divison of II-VI Incorporated (Now: a division of Endicott Interconnect Technologies, Inc., 〈http://www.evmicroelectronics.com/〉), Saxonburg, PA 16056, semiconductor material properties on the web page: 〈http://www.evproducts.com〉 last accessed on June 2009.
  • 11
    • 77649274654 scopus 로고    scopus 로고
    • Firestone, R.B, Shirley, V.S, 1996. Table of Isotopes, eighth ed, CD-ROM Ver. 1.0, also on the web page:, last accessed on July, 2009
    • Firestone, R.B., Shirley, V.S., 1996. Table of Isotopes, eighth ed., CD-ROM Ver. 1.0, also on the web page: 〈http://www.nndc.bnl.gov/nndc/ensdf/〉, last accessed on July, 2009.
  • 14
    • 0003492094 scopus 로고
    • ISO (International Organization for Standardization), Geneva, Switzerland. 92-67-10188-9
    • ISO (International Organization for Standardization). A Guide to the expression of uncertainty in measurement. first ed. (1995), Geneva, Switzerland. 92-67-10188-9
    • (1995) A Guide to the expression of uncertainty in measurement. first ed.
  • 17
    • 0035250917 scopus 로고    scopus 로고
    • Chracterisation of cadmium zinc telluride detector spectra-application to the analysis of spent fuel spectra
    • Mortreau P., and Berndt R. Chracterisation of cadmium zinc telluride detector spectra-application to the analysis of spent fuel spectra. Nucl. Instrum. Methods A 458 (2001) 183-188
    • (2001) Nucl. Instrum. Methods A , vol.458 , pp. 183-188
    • Mortreau, P.1    Berndt, R.2
  • 19
    • 0347627354 scopus 로고    scopus 로고
    • Performance of CdTe, HPGe and NaI(Tl) detectors for radioactivity measurements
    • Perez-Andujar A., and Pibida L. Performance of CdTe, HPGe and NaI(Tl) detectors for radioactivity measurements. Appl. Radiat. Isot. 60 (2004) 41-47
    • (2004) Appl. Radiat. Isot. , vol.60 , pp. 41-47
    • Perez-Andujar, A.1    Pibida, L.2
  • 20
    • 0003251891 scopus 로고
    • Semiconductors for room temperature nuclear detector applications
    • Academic Press, New York. ISBN:0-12-752143-7
    • Schlesinger, T.E., James, R.B., 1995. Semiconductors for room temperature nuclear detector applications. Semiconductors and Semimetals, Vol. 43, Academic Press, New York. ISBN:0-12-752143-7
    • (1995) Semiconductors and Semimetals , vol.43
    • Schlesinger, T.E.1    James, R.B.2
  • 21
    • 84922552732 scopus 로고    scopus 로고
    • Oxford Science Publications, Oxford Univ. Press, Oxford. 978-0-19-852784-8
    • Spieler H. Semiconductor Detector Systems. 3rd ed. (2008), Oxford Science Publications, Oxford Univ. Press, Oxford. 978-0-19-852784-8
    • (2008) Semiconductor Detector Systems. 3rd ed.
    • Spieler, H.1
  • 22
    • 77649271350 scopus 로고    scopus 로고
    • Sudár, S., 2002. TrueCoinc, a software utility for calculation of the true coincidence correction, in the specialized software utilities for gamma spectrometry, IAEA-TECDOC-1275, pp. 37-38, International Atomic Energy Agency, Vienna, ISSN 1011-4289.
    • Sudár, S., 2002. "TrueCoinc", a software utility for calculation of the true coincidence correction, in the specialized software utilities for gamma spectrometry, IAEA-TECDOC-1275, pp. 37-38, International Atomic Energy Agency, Vienna, ISSN 1011-4289.
  • 23
    • 33751507488 scopus 로고    scopus 로고
    • Determination of the cascade summation coefficients of gamma quanta for a semiconductor detector in the 59-2754 keV range
    • Tereshchenko E.E., and Ras'ko M.A. Determination of the cascade summation coefficients of gamma quanta for a semiconductor detector in the 59-2754 keV range. Meas. Tech. 49 9 (2006) 932-938
    • (2006) Meas. Tech. , vol.49 , Issue.9 , pp. 932-938
    • Tereshchenko, E.E.1    Ras'ko, M.A.2
  • 25
    • 53049099733 scopus 로고    scopus 로고
    • Detection efficiency of CdZnTe detector in the range of 30-670 keV gamma ray energy for a disc source geometry (in Turkish)
    • Yücel H., Solmaz A.N., Kurt A., İnal T., and Bor D. Detection efficiency of CdZnTe detector in the range of 30-670 keV gamma ray energy for a disc source geometry (in Turkish). J. Fac. Eng. Arch. Gazi Univ. 23 3 (2008) 699-707
    • (2008) J. Fac. Eng. Arch. Gazi Univ. , vol.23 , Issue.3 , pp. 699-707
    • Yücel, H.1    Solmaz, A.N.2    Kurt, A.3    Inal, T.4    Bor, D.5
  • 26
    • 77949264251 scopus 로고    scopus 로고
    • A semi-empirical method for calculation of true coincidence corrections for the case of a close-in detection in γ-ray spectrometry
    • 10.1007/s10967-009-0360-8
    • Yücel H., Solmaz A.N., Köse E., and Bor D. A semi-empirical method for calculation of true coincidence corrections for the case of a close-in detection in γ-ray spectrometry. J. Radioanal. Nucl. Chem. (2009) 10.1007/s10967-009-0360-8
    • (2009) J. Radioanal. Nucl. Chem.
    • Yücel, H.1    Solmaz, A.N.2    Köse, E.3    Bor, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.