메뉴 건너뛰기




Volumn 10, Issue 3, 2010, Pages 599-603

3-D reconstruction of gas clouds by scanning imaging ir spectroscopy and tomography

Author keywords

3 D imaging; IR spectroscopy; Remote sensing; Tomography

Indexed keywords

3-D SHAPE; 3D IMAGING; 3D RECONSTRUCTION; 3D STRUCTURES; EMERGENCY RESPONSE; EMERGENCY RESPONSE PERSONNELS; GAS CLOUDS; HAZARDOUS COMPOUNDS; IR IMAGES; IR SPECTROSCOPY; LINE OF SIGHT; MEASUREMENT SETUP; REMOTE SENSING SYSTEM; SAFETY MEASURES; SCANNING IMAGING; SINGLE IMAGES; TERRORIST ATTACKS; TOXIC CLOUDS;

EID: 77649125263     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2009.2038450     Document Type: Article
Times cited : (16)

References (9)
  • 1
    • 0000648511 scopus 로고    scopus 로고
    • Fast on-site GC/MS analysis of hazardous compound emissions from fires and chemical accidents
    • G. Matz, W. Schröder, A. Harder, A. Schillings, and P. Rechenbach, "Fast on-site GC/MS analysis of hazardous compound emissions from fires and chemical accidents," Field Anal. Chem. Technol., vol. 1, pp. 181-194, 1997.
    • (1997) Field Anal. Chem. Technol , vol.1 , pp. 181-194
    • Matz, G.1    Schröder, W.2    Harder, A.3    Schillings, A.4    Rechenbach, P.5
  • 2
    • 0035267576 scopus 로고    scopus 로고
    • Diurnal changes in volcanic plume chemistry observed by lunar and solar occultation spectroscopy
    • M. R. Burton, C. Oppenheimer, L. A. Horrocks, and P. W. Francis, "Diurnal changes in volcanic plume chemistry observed by lunar and solar occultation spectroscopy," Geophys. Res. Lett., vol. 28, pp. 843-846, 2001.
    • (2001) Geophys. Res. Lett , vol.28 , pp. 843-846
    • Burton, M.R.1    Oppenheimer, C.2    Horrocks, L.A.3    Francis, P.W.4
  • 3
    • 0031189190 scopus 로고    scopus 로고
    • Analysis of aircraft exhaust with Fourier-transform infrared emission spectroscopy
    • J. Heland and K. Schäfer, "Analysis of aircraft exhaust with Fourier-transform infrared emission spectroscopy," Appl. Opt., vol. 36, pp. 4922-4931, 1997.
    • (1997) Appl. Opt , vol.36 , pp. 4922-4931
    • Heland, J.1    Schäfer, K.2
  • 4
    • 33644635100 scopus 로고    scopus 로고
    • New scanning infrared gas imaging system (SIGIS 2) for emergency response forces
    • R. Harig, G. Matz, P. Rusch, H.-H. Gerhard, J.-H. Gerhard, and V. Schlabs, J. O. Jensen and J.-M. Thériault, Eds
    • R. Harig, G. Matz, P. Rusch, H.-H. Gerhard, J.-H. Gerhard, and V. Schlabs, J. O. Jensen and J.-M. Thériault, Eds., "New scanning infrared gas imaging system (SIGIS 2) for emergency response forces," Chem. Biol. Standoff Detection III, SPIE, vol. 5995, pp. 174-181, 2005.
    • (2005) Chem. Biol. Standoff Detection III, SPIE , vol.5995 , pp. 174-181
  • 5
    • 35649004251 scopus 로고    scopus 로고
    • Infrared remote sensing of hazardous vapours: Surveillance of public areas during the FIFA football world cup 2006
    • 65381Z-10, DOI:10.1117/12.720227
    • R. Harig, G. Matz, P. Rusch, H. Gerhard, J. Gerhard, and V. Schlabs, "Infrared remote sensing of hazardous vapours: Surveillance of public areas during the FIFA football world cup 2006," in Proc. SPIE, 2007, vol. 6538, pp. 65381Z-1-65381Z-10, DOI:10.1117/12.720227.
    • (2007) Proc. SPIE , vol.6538
    • Harig, R.1    Matz, G.2    Rusch, P.3    Gerhard, H.4    Gerhard, J.5    Schlabs, V.6
  • 6
    • 4344564956 scopus 로고    scopus 로고
    • Passive remote sensing of pollutant clouds by FTIR spec-trometry: Signal-to-noise ratio as a function of spectral resolution
    • R. Harig, "Passive remote sensing of pollutant clouds by FTIR spec-trometry: Signal-to-noise ratio as a function of spectral resolution," Appl. Opt., vol. 43, no. 23, pp. 4603-4610, 2004.
    • (2004) Appl. Opt , vol.43 , Issue.23 , pp. 4603-4610
    • Harig, R.1
  • 7
    • 0035613685 scopus 로고    scopus 로고
    • Toxic cloud imaging by infrared spectrometry: A scanning FTIR system for identification and visualization
    • R. Harig and G. Matz, "Toxic cloud imaging by infrared spectrometry: A scanning FTIR system for identification and visualization," Field Anal. Chem. Technol., vol. 5, no. 1-2, pp. 75-90, 2001.
    • (2001) Field Anal. Chem. Technol , vol.5 , Issue.1-2 , pp. 75-90
    • Harig, R.1    Matz, G.2
  • 8
    • 62649161205 scopus 로고
    • Vapor-detection sensitivity as a function of spectral resolution for a single lorentzian band
    • D. F. Flanigan, "Vapor-detection sensitivity as a function of spectral resolution for a single lorentzian band," Appl. Opt., vol. 34, pp. 2636-2639, 1995.
    • (1995) Appl. Opt , vol.34 , pp. 2636-2639
    • Flanigan, D.F.1
  • 9
    • 0030321731 scopus 로고    scopus 로고
    • Prediction of the limits of detection of hazardous vapors by passive infrared with the use of Modtran
    • D. F. Flanigan, "Prediction of the limits of detection of hazardous vapors by passive infrared with the use of Modtran," Appl. Opt., vol. 35, pp. 6090-6098, 1996.
    • (1996) Appl. Opt , vol.35 , pp. 6090-6098
    • Flanigan, D.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.