메뉴 건너뛰기




Volumn 5995, Issue , 2005, Pages

New Scanning Infrared Gas Imaging System (SIGIS 2) for emergency response forces

Author keywords

Emergency response; FTIR; Imaging spectrometry; Passive; Passive infrared spectrometry; Remote sensing; Scanning imaging FTIR spectrometer

Indexed keywords

ACCIDENTS; COLOR; FOURIER TRANSFORM INFRARED SPECTROSCOPY; HAZARDOUS MATERIALS; INFRARED IMAGING; INTERFEROMETERS; REMOTE SENSING;

EID: 33644635100     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.630818     Document Type: Conference Paper
Times cited : (16)

References (8)
  • 2
    • 0034372168 scopus 로고    scopus 로고
    • Hand-portable Gas-Detector Array (GDA) for rapid field detection and identification of chemical threat
    • Matz, G., Hunte, T., Schröder, W.: "Hand-Portable Gas-Detector Array (GDA) for Rapid Field Detection and Identification of Chemical Threat", Field Analytical Chemistry and Technology 4 (4), 195-203, 2000.
    • (2000) Field Analytical Chemistry and Technology , vol.4 , Issue.4 , pp. 195-203
    • Matz, G.1    Hunte, T.2    Schröder, W.3
  • 3
    • 0035764037 scopus 로고    scopus 로고
    • Scanning infrared remote sensing system for identification, visualization, and quantification of airborne pollutants
    • Instrumentation forAir Pollution and Global Atmospheric Monitoring, James O. Jensen, Robert L. Spellicy, Editors
    • Harig, R., Matz, G., Rusch, P.: "Scanning Infrared Remote Sensing System for Identification, Visualization, and Quantification of Airborne Pollutants" in Instrumentation forAir Pollution and Global Atmospheric Monitoring, James O. Jensen, Robert L. Spellicy, Editors, Proc. SPIE 4574, 83-94, 2002.
    • (2002) Proc. SPIE , vol.4574 , pp. 83-94
    • Harig, R.1    Matz, G.2    Rusch, P.3
  • 4
    • 4344564956 scopus 로고    scopus 로고
    • Passive remote sensing of pollutant clouds by FTIR spectrometry: Signal-to-noise ratio as a function of spectral resolution
    • Harig, R.: "Passive remote sensing of pollutant clouds by FTIR spectrometry: Signal-to-noise ratio as a function of spectral resolution," Applied Optics, Volume 43 (23), 4603-4610, 2004.
    • (2004) Applied Optics, Volume , vol.43 , Issue.23 , pp. 4603-4610
    • Harig, R.1
  • 5
    • 0033435413 scopus 로고    scopus 로고
    • Thermal stability evaluation for passive FTIR spectrometry
    • Combs, R. J.: "Thermal Stability Evaluation for Passive FTIR Spectrometry," Field Analytical Chemistry and Technology 3, 81-94 (1999).
    • (1999) Field Analytical Chemistry and Technology , vol.3 , pp. 81-94
    • Combs, R.J.1
  • 6
    • 0042231885 scopus 로고    scopus 로고
    • Modeling the responsivity and self-emission of a double-beam Fourier-transform infrared interferometer
    • Thériault, J.-M.: "Modeling the responsivity and self-emission of a double-beam Fourier-transform infrared interferometer", Applied Optics 38, 505-515 (1999).
    • (1999) Applied Optics , vol.38 , pp. 505-515
    • Thériault, J.-M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.