메뉴 건너뛰기




Volumn 54, Issue 1, 2010, Pages 43-47

Reproducibility of peripapillary retinal nerve fiber layer thickness with spectral domain cirrus high-definition optical coherence tomography in normal eyes

Author keywords

Optical coherence tomography; Reproducibility; Retinal nerve fiber layer thickness

Indexed keywords

ADULT; ARTICLE; CORRELATION COEFFICIENT; EYE; FEMALE; HIGH DEFINITION OPTICAL COHERENCE TOMOGRAPHY; HUMAN; KAPPA STATISTICS; MALE; NERVE FIBER; NORMAL HUMAN; NOSE; OPTIC DISK; OPTICAL COHERENCE TOMOGRAPHY; PERIPAPILLARY RETINAL NERVE FIBER LAYER THICKNESS; PRIORITY JOURNAL; PROBABILITY; REPRODUCIBILITY; TEST RETEST RELIABILITY; THICKNESS;

EID: 77249102285     PISSN: 00215155     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10384-009-0762-8     Document Type: Article
Times cited : (41)

References (23)
  • 1
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • 10.1126/science.1957169 1:STN:280:DyaK38%2Fms12lsA%3D%3D 1957169
    • D. Huang E.A. Swanson C.P. Lin, et al. 1991 Optical coherence tomography Science 254 1178 1181 10.1126/science.1957169 1:STN:280:DyaK38%2Fms12lsA%3D%3D 1957169
    • (1991) Science , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 2
    • 0028948087 scopus 로고
    • Optical coherence tomography of the human retina
    • 1:STN:280:DyaK2M7psVantA%3D%3D 7887846
    • M.R. Hee J.A. Izatt E.A. Swanson, et al. 1995 Optical coherence tomography of the human retina Arch Ophthalmol 113 325 332 1:STN:280: DyaK2M7psVantA%3D%3D 7887846
    • (1995) Arch Ophthalmol , vol.113 , pp. 325-332
    • Hee, M.R.1    Izatt, J.A.2    Swanson, E.A.3
  • 3
    • 0346729846 scopus 로고    scopus 로고
    • Optical coherence tomography to detect and manage retinal disease and glaucoma
    • DOI 10.1016/S0002-9394(03)00792-X
    • G.J. Jaffe J. Caprioli 2004 Optical coherence tomography to detect and manage retinal disease and glaucoma Am J Ophthalmol 137 156 169 10.1016/S0002-9394(03)00792-X 14700659 (Pubitemid 38045202)
    • (2004) American Journal of Ophthalmology , vol.137 , Issue.1 , pp. 156-169
    • Jaffe, G.J.1    Caprioli, J.2
  • 4
    • 40849130823 scopus 로고    scopus 로고
    • Role of optic nerve imaging in glaucoma clinical practice and clinical trials
    • 10.1016/j.ajo.2007.12.018 18295183
    • D.S. Greenfield R.N. Weinreb 2008 Role of optic nerve imaging in glaucoma clinical practice and clinical trials Am J Ophthalmol 145 598 603 10.1016/j.ajo.2007.12.018 18295183
    • (2008) Am J Ophthalmol , vol.145 , pp. 598-603
    • Greenfield, D.S.1    Weinreb, R.N.2
  • 5
    • 1542398242 scopus 로고    scopus 로고
    • In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
    • 10.1364/OL.29.000480 15005199
    • N. Nassif B. Cense B.H. Park, et al. 2004 In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography Opt Lett 29 480 482 10.1364/OL.29.000480 15005199
    • (2004) Opt Lett , vol.29 , pp. 480-482
    • Nassif, N.1    Cense, B.2    Park, B.H.3
  • 8
    • 51349087739 scopus 로고    scopus 로고
    • Correlation of Fourier domain optical coherence tomography retinal nerve fiber layer maps with visual fields in nonarteritic ischemic optic neuropathy
    • 18777877
    • T. Alasil O. Tan A.T. Lu D. Huang A.A. Sadun 2008 Correlation of Fourier domain optical coherence tomography retinal nerve fiber layer maps with visual fields in nonarteritic ischemic optic neuropathy Ophthalmic Surg Lasers Imaging 39 S71 S79 18777877
    • (2008) Ophthalmic Surg Lasers Imaging , vol.39
    • Alasil, T.1    Tan, O.2    Lu, A.T.3    Huang, D.4    Sadun, A.A.5
  • 9
    • 58149260765 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber layer thickness measurements using 3D Fourierdomain OCT
    • 10.1167/iovs.07-1435 18676630
    • M.N. Menke P. Knecht V. Sturm S. Dabov J. Funk 2008 Reproducibility of nerve fiber layer thickness measurements using 3D Fourierdomain OCT Invest Ophthalmol Vis Sci 49 5386 5391 10.1167/iovs.07-1435 18676630
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 5386-5391
    • Menke, M.N.1    Knecht, P.2    Sturm, V.3    Dabov, S.4    Funk, J.5
  • 10
    • 0035889428 scopus 로고    scopus 로고
    • Planning a reproducibility study: How many subjects and how many replicates per subject for an expected width of the 95 per cent confidence interval of the intraclass correlation coefficient
    • DOI 10.1002/sim.935
    • B. Giraudeau J.Y. Mary 2001 Planning a reproducibility study: how many subjects and how many replicates per subject for an expected width of the 95 per cent confidence interval of the intraclass correlation coefficient Stat Med 20 3205 3214 10.1002/sim.935 1:STN:280:DC%2BD3MnpvVyktA%3D%3D 11746313 (Pubitemid 33034881)
    • (2001) Statistics in Medicine , vol.20 , Issue.21 , pp. 3205-3214
    • Giraudeau, B.1    Mary, J.Y.2
  • 11
    • 23244456347 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    • DOI 10.1167/iovs.04-1174
    • D.L. Budenz R.T. Chang X. Huang R.W. Knighton J.M. Tielsch 2005 Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes Invest Ophthalmol Vis Sci 46 2440 2443 10.1167/iovs.04-1174 15980233 (Pubitemid 43119491)
    • (2005) Investigative Ophthalmology and Visual Science , vol.46 , Issue.7 , pp. 2440-2443
    • Budenz, D.L.1    Chang, R.T.2    Huang, X.3    Knighton, R.W.4    Tielsch, J.M.5
  • 12
    • 41149149872 scopus 로고    scopus 로고
    • Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes
    • 10.1016/j.ophtha.2007.05.035 17706287
    • D.L. Budenz M.J. Fredette W.J. Feuer D.R. Anderson 2008 Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes Ophthalmology 115 661 666 10.1016/j.ophtha.2007.05.035 17706287
    • (2008) Ophthalmology , vol.115 , pp. 661-666
    • Budenz, D.L.1    Fredette, M.J.2    Feuer, W.J.3    Anderson, D.R.4
  • 13
    • 3343019470 scopus 로고
    • Measuring nominal scale agreement among many raters
    • 10.1037/h0031619
    • J.L. Fleiss 1971 Measuring nominal scale agreement among many raters Psychol Bull 76 378 382 10.1037/h0031619
    • (1971) Psychol Bull , vol.76 , pp. 378-382
    • Fleiss, J.L.1
  • 14
    • 58149409073 scopus 로고
    • Large sample variance of kappa in the case of different sets of raters
    • 10.1037/0033-2909.86.5.974
    • J.L. Fleiss J.C. Nee J.R. Landis 1979 Large sample variance of kappa in the case of different sets of raters Psychol Bull 86 974 977 10.1037/0033-2909.86.5.974
    • (1979) Psychol Bull , vol.86 , pp. 974-977
    • Fleiss, J.L.1    Nee, J.C.2    Landis, J.R.3
  • 16
    • 56149104617 scopus 로고    scopus 로고
    • Longitudinal variability of optic disc and retinal nerve fiber layer measurements
    • 10.1167/iovs.07-1187 18539940
    • C.K. Leung C.Y. Cheung D. Lin C.P. Pang D.S. Lam R.N. Weinreb 2008 Longitudinal variability of optic disc and retinal nerve fiber layer measurements Invest Ophthalmol Vis Sci 49 4886 4892 10.1167/iovs.07-1187 18539940
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 4886-4892
    • Leung, C.K.1    Cheung, C.Y.2    Lin, D.3    Pang, C.P.4    Lam, D.S.5    Weinreb, R.N.6
  • 18
    • 33646940387 scopus 로고    scopus 로고
    • Diagnosing glaucoma progression: Current practice and promising technologies
    • DOI 10.1097/01.icu.0000193089.52561.ac, PII 0005573520060400000007
    • A. Giangiacomo D. Garway-Heath J. Caprioli 2006 Diagnosing glaucoma progression: current practice and promising technologies Curr Opin Ophthalmol 17 153 162 10.1097/01.icu.0000193089.52561.ac 16552250 (Pubitemid 43790811)
    • (2006) Current Opinion in Ophthalmology , vol.17 , Issue.2 , pp. 153-162
    • Giangiacomo, A.1    Garway-Heath, D.2    Caprioli, J.3
  • 19
    • 33646911370 scopus 로고    scopus 로고
    • Retinal nerve fiber layer analysis in the diagnosis of glaucoma
    • 16552246
    • L.M. Zangwill C. Bowd 2006 Retinal nerve fiber layer analysis in the diagnosis of glaucoma Curr Opin Ophthalmol 17 120 131 16552246
    • (2006) Curr Opin Ophthalmol , vol.17 , pp. 120-131
    • Zangwill, L.M.1    Bowd, C.2
  • 20
    • 35348938087 scopus 로고    scopus 로고
    • A framework for comparing structural and functional measures of glaucomatous damage
    • DOI 10.1016/j.preteyeres.2007.08.001, PII S1350946207000559
    • D.C. Hood R.H. Kardon 2007 A framework for comparing structural and functional measures of glaucomatous damage Prog Retin Eye Res 26 688 710 10.1016/j.preteyeres.2007.08.001 17889587 (Pubitemid 47615565)
    • (2007) Progress in Retinal and Eye Research , vol.26 , Issue.6 , pp. 688-710
    • Hood, D.C.1    Kardon, R.H.2
  • 21
    • 40049096480 scopus 로고    scopus 로고
    • New developments in optical coherence tomography for glaucoma
    • DOI 10.1097/ICU.0b013e3282f36cdf, PII 0005573520080300000009
    • R. Chang D.L. Budenz 2008 New developments in optical coherence tomography for glaucoma Curr Opin Ophthalmol 19 127 135 10.1097/ICU. 0b013e3282f36cdf 18301286 (Pubitemid 351322815)
    • (2008) Current Opinion in Ophthalmology , vol.19 , Issue.2 , pp. 127-135
    • Chang, R.1    Budenz, D.L.2
  • 22
    • 40049083269 scopus 로고    scopus 로고
    • New developments in scanning laser polarimetry for glaucoma
    • DOI 10.1097/ICU.0b013e3282f4b1c2, PII 0005573520080300000010
    • H.G. Lemij N.J. Reus 2008 New developments in scanning laser polarimetry for glaucoma Curr Opin Ophthalmol 19 136 140 10.1097/ICU.0b013e3282f4b1c2 18301287 (Pubitemid 351322816)
    • (2008) Current Opinion in Ophthalmology , vol.19 , Issue.2 , pp. 136-140
    • Lemij, H.G.1    Reus, N.J.2
  • 23
    • 14744284163 scopus 로고    scopus 로고
    • The kappa statistic in reliability studies: Use, interpretation, and sample size requirements
    • 15733050
    • J. Sim C.C. Wright 2005 The kappa statistic in reliability studies: use, interpretation, and sample size requirements Phys Ther 85 257 268 15733050
    • (2005) Phys Ther , vol.85 , pp. 257-268
    • Sim, J.1    Wright, C.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.