Volumn 24, Issue 2, 2010, Pages 233-239

Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closure

Author keywords

Angle closure; Anterior segment; Glaucoma; Narrow angles; Optical coherence tomography; Ultrasound biomicroscopy

Indexed keywords

ADULT; AGED; ANTERIOR EYE CHAMBER; ANTERIOR EYE SEGMENT; ARTICLE; BIOMICROSCOPY; CLINICAL ARTICLE; CLINICAL TRIAL; CLOSED ANGLE GLAUCOMA; CONTROLLED STUDY; CROSS-SECTIONAL STUDY; DIAGNOSTIC ACCURACY; EQUIPMENT; EUROPEAN AMERICAN; FEMALE; HUMAN; INTERMETHOD COMPARISON; IRIS; MALE; OPTICAL COHERENCE TOMOGRAPHY; OPTOMETRY; PRIMARY ANGLE CLOSURE; PRIMARY GLAUCOMA; SCLERA; SUSPECTED PRIMARY ANGLE CLOSURE; TRABECULAR MESHWORK; ULTRASOUND SCANNER;

EID: 77049125761     PISSN: 0950222X     EISSN: 14765454     Source Type: Journal    
DOI: 10.1038/eye.2009.103     Document Type: Article
Times cited : (38)

References (27)
  • 1
    • 33644655886 scopus 로고    scopus 로고
    • The number of people with glaucoma worldwide in 2010 and 2020
    • Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Br J Ophthalmol 2006; 90(3): 262-267.
    • (2006) Br J Ophthalmol , vol.90 , Issue.3 , pp. 262-267
    • Quigley, H.A.1    Broman, A.T.2
  • 2
    • 0031442088 scopus 로고    scopus 로고
    • Incidence of acute primary angle-closure glaucoma in Singapore. An island-wide survey
    • Seah SK, Foster PJ, Chew PT, Jap A, Oen F, Fam HB et al. Incidence of acute primary angle-closure glaucoma in Singapore. An island-wide survey. Arch Ophthalmol 1997; 115(11): 1436-1440.
    • (1997) Arch Ophthalmol , vol.115 , Issue.11 , pp. 1436-1440
    • Seah, S.K.1    Foster, P.J.2    Chew, P.T.3    Jap, A.4    Oen, F.5    Fam, H.B.6
  • 4
    • 0033653103 scopus 로고    scopus 로고
    • Long-term clinical course of primary angle-closure glaucoma in an Asian population
    • Alsagoff Z, Aung T, Ang LP, Chew PT. Long-term clinical course of primary angle-closure glaucoma in an Asian population. Ophthalmology 2000; 107(12): 2300-2304.
    • (2000) Ophthalmology , vol.107 , Issue.12 , pp. 2300-2304
    • Alsagoff, Z.1    Aung, T.2    Ang, L.P.3    Chew, P.T.4
  • 5
    • 0024497206 scopus 로고
    • Comparative studies of the width of the anterior chamber angle using echography and gonioscopy
    • Makabe R. Comparative studies of the width of the anterior chamber angle using echography and gonioscopy. Klin Monatsbl Augenheilkd 1989; 194(1): 6-9.
    • (1989) Klin Monatsbl Augenheilkd , vol.194 , Issue.1 , pp. 6-9
    • Makabe, R.1
  • 6
    • 0026552857 scopus 로고
    • Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes
    • Pavlin CJ, Harasiewicz K, Foster FS. Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. Am J Ophthalmol 1992; 113(4): 381-389.
    • (1992) Am J Ophthalmol , vol.113 , Issue.4 , pp. 381-389
    • Pavlin, C.J.1    Harasiewicz, K.2    Foster, F.S.3
  • 7
    • 0034068551 scopus 로고    scopus 로고
    • Quantitative assessment of the anterior segment using ultrasound biomicroscopy
    • Ishikawa H, Liebmann JM, Ritch R. Quantitative assessment of the anterior segment using ultrasound biomicroscopy. Curr Opin Ophthalmol 2000; 11(2): 133-139.
    • (2000) Curr Opin Ophthalmol , vol.11 , Issue.2 , pp. 133-139
    • Ishikawa, H.1    Liebmann, J.M.2    Ritch, R.3
  • 8
    • 0037373408 scopus 로고    scopus 로고
    • A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes
    • Gazzard G, Friedman DS, Devereux JG, Chew P, Seah SK. A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in Asian eyes. Ophthalmology 2003; 110(3): 630-638.
    • (2003) Ophthalmology , vol.110 , Issue.3 , pp. 630-638
    • Gazzard, G.1    Friedman, D.S.2    Devereux, J.G.3    Chew, P.4    Seah, S.K.5
  • 10
    • 33845730860 scopus 로고    scopus 로고
    • Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes
    • Nolan WP, See JL, Chew PT, Friedman DS, Smith SD, Radhakrishnan S et al. Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes. Ophthalmology 2007; 114(1): 33-39.
    • (2007) Ophthalmology , vol.114 , Issue.1 , pp. 33-39
    • Nolan, W.P.1    See, J.L.2    Chew, P.T.3    Friedman, D.S.4    Smith, S.D.5    Radhakrishnan, S.6
  • 11
    • 23844543530 scopus 로고    scopus 로고
    • Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles
    • Radhakrishnan S, Goldsmith J, Huang D, Westphal V, Dueker DK, Rollins AM et al. Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles. Arch Ophthalmol 2005; 123(8): 1053-1059.
    • (2005) Arch Ophthalmol , vol.123 , Issue.8 , pp. 1053-1059
    • Radhakrishnan, S.1    Goldsmith, J.2    Huang, D.3    Westphal, V.4    Dueker, D.K.5    Rollins, A.M.6
  • 12
    • 34247344135 scopus 로고    scopus 로고
    • Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment
    • Dada T, Sihota R, Gadia R, Aggarwal A, Mandal S, Gupta V. Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment. J Cataract Refract Surg 2007; 33(5): 837-840.
    • (2007) J Cataract Refract Surg , vol.33 , Issue.5 , pp. 837-840
    • Dada, T.1    Sihota, R.2    Gadia, R.3    Aggarwal, A.4    Mandal, S.5    Gupta, V.6
  • 13
    • 12144288635 scopus 로고    scopus 로고
    • Defining 'occludable' angles in population surveys: Drainage angle width, peripheral anterior synechiae, and glaucomatous optic neuropathy in east Asian people
    • Foster PJ, Aung T, Nolan WP, Machin D, Baasanhu J, Khaw PT et al. Defining 'occludable' angles in population surveys: drainage angle width, peripheral anterior synechiae, and glaucomatous optic neuropathy in east Asian people. Br J Ophthalmol 2004; 88(4): 486-490.
    • (2004) Br J Ophthalmol , vol.88 , Issue.4 , pp. 486-490
    • Foster, P.J.1    Aung, T.2    Nolan, W.P.3    MacHin, D.4    Baasanhu, J.5    Khaw, P.T.6
  • 14
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476): 307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 0033859115 scopus 로고    scopus 로고
    • Inadvertent corneal indentation may cause artifactitious widening of the iridocorneal angle on ultrasound biomicroscopy
    • Ishikawa H, Inazumi K, Liebmann JM, Ritch R. Inadvertent corneal indentation may cause artifactitious widening of the iridocorneal angle on ultrasound biomicroscopy. Ophthalmic Surg Lasers 2000; 31: 342-345.
    • (2000) Ophthalmic Surg Lasers , vol.31 , pp. 342-345
    • Ishikawa, H.1    Inazumi, K.2    Liebmann, J.M.3    Ritch, R.4
  • 16
    • 3042641066 scopus 로고    scopus 로고
    • Reproduzierbarkeit der goniometrie mittels spaltlampen-adaptierter optischer koharenztomographie
    • Karandish A, Wirbelauer C, Haberle H, Pham DT. Reproducibility of goniometry with slitlamp-adapted optical coherence tomography. Ophthalmologe 2004; 101(6): 608-613. German. (Pubitemid 38843107)
    • (2004) Ophthalmologe , vol.101 , Issue.6 , pp. 608-613
    • Karandish, A.1    Wirbelauer, C.2    Haberle, H.3    Pham, D.T.4
  • 17
    • 29144432268 scopus 로고    scopus 로고
    • Imaging of the anterior eye chamber with optical coherence tomography
    • Wirbelauer C, Gochmann R, Pham DT. Imaging of the anterior eye chamber with optical coherence tomography. Klin Monatsbl Augenheilkd 2005; 222(11): 856-862.
    • (2005) Klin Monatsbl Augenheilkd , vol.222 , Issue.11 , pp. 856-862
    • Wirbelauer, C.1    Gochmann, R.2    Pham, D.T.3
  • 18
    • 35748951951 scopus 로고    scopus 로고
    • Changes in anterior segment morphology in response to illumination and after laser iridotomy in Asian eyes: An anterior segment OCT study
    • See JL, Chew PT, Smith SD, Nolan WP, Chan YH, Huang D et al. Changes in anterior segment morphology in response to illumination and after laser iridotomy in Asian eyes: an anterior segment OCT study. Br J Ophthalmol 2007; 91(11): 1485-1489.
    • (2007) Br J Ophthalmol , vol.91 , Issue.11 , pp. 1485-1489
    • See, J.L.1    Chew, P.T.2    Smith, S.D.3    Nolan, W.P.4    Chan, Y.H.5    Huang, D.6
  • 19
    • 35148850981 scopus 로고    scopus 로고
    • Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT
    • Leung CK, Cheung CY, Li H, Dorairaj S, Yiu CK, Wong AL et al. Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT. Invest Ophthalmol Vis Sci 2007; 48(9): 4116-4122.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , Issue.9 , pp. 4116-4122
    • Leung, C.K.1    Cheung, C.Y.2    Li, H.3    Dorairaj, S.4    Yiu, C.K.5    Wong, A.L.6
  • 20
    • 33751070336 scopus 로고    scopus 로고
    • Anterior chamber angle measurement with optical coherence tomography: Intraobserver and interobserver variability
    • Muller M, Dahmen G, Porksen E, Geerling G, Laqua H, Ziegler A et al. Anterior chamber angle measurement with optical coherence tomography: intraobserver and interobserver variability. J Cataract Refract Surg 2006; 32(11): 1803-1808.
    • (2006) J Cataract Refract Surg , vol.32 , Issue.11 , pp. 1803-1808
    • Muller, M.1    Dahmen, G.2    Porksen, E.3    Geerling, G.4    Laqua, H.5    Ziegler, A.6
  • 22
    • 0028020440 scopus 로고
    • Measurement of ultrasound biomicroscopy images: Intraobserver and interobserver reliability
    • Tello C, Liebmann J, Potash SD, Cohen H, Ritch R. Measurement of ultrasound biomicroscopy images: intraobserver and interobserver reliability. Invest Ophthalmol Vis Sci 1994; 35(9): 3549-3552.
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , Issue.9 , pp. 3549-3552
    • Tello, C.1    Liebmann, J.2    Potash, S.D.3    Cohen, H.4    Ritch, R.5
  • 23
    • 0031757658 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy. II. Intraobserver and interobserver reproducibility of measurements
    • Urbak SF, Pedersen JK, Thorsen TT. Ultrasound biomicroscopy. II. Intraobserver and interobserver reproducibility of measurements. Acta Ophthalmol Scand 1998; 76(5): 546-549.
    • (1998) Acta Ophthalmol Scand , vol.76 , Issue.5 , pp. 546-549
    • Urbak, S.F.1    Pedersen, J.K.2    Thorsen, T.T.3
  • 24
    • 0030958190 scopus 로고    scopus 로고
    • Intraobserver and interobserver agreement in evaluating the anterior chamber angle configuration by ultrasound biomicroscopy
    • Spaeth GL, Azuara-Blanco A, Araujo SV, Augsburger JJ. Intraobserver and interobserver agreement in evaluating the anterior chamber angle configuration by ultrasound biomicroscopy. J Glaucoma 1997; 6(1): 13-17.
    • (1997) J Glaucoma , vol.6 , Issue.1 , pp. 13-17
    • Spaeth, G.L.1    Azuara-Blanco, A.2    Araujo, S.V.3    Augsburger, J.J.4
  • 25
    • 35748983510 scopus 로고    scopus 로고
    • Anterior segment imaging for glaucoma OCT or UBM?
    • Ishikawa H. Anterior segment imaging for glaucoma: OCT or UBM? Br J Ophthalmol 2007; 91(11): 1420-1421.
    • (2007) Br J Ophthalmol , vol.91 , Issue.11 , pp. 1420-1421
    • Ishikawa, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.