-
1
-
-
0036135669
-
Laser in situ keratomileusis for myopia and astigmatism: Safety and efficacy: A report by the American Academy of Ophthalmology
-
Sugar A, Rapuano CJ, Culbertson WW, Huang D, Varley GA, Agapitos PJ, et al. Laser in situ keratomileusis for myopia and astigmatism: Safety and efficacy: A report by the American Academy of Ophthalmology. Ophthalmology. 2002; 109(1):175-87.
-
(2002)
Ophthalmology
, vol.109
, Issue.1
, pp. 175-187
-
-
Sugar, A.1
Rapuano, C.J.2
Culbertson, W.W.3
Huang, D.4
Varley, G.A.5
Agapitos, P.J.6
-
2
-
-
33846545864
-
-
Alves MR, Chamon W, Nosé W, editores. Rio de Janeiro: Cultura Médica
-
Alves MR, Chamon W, Nosé W, editores. Cirurgia refrativa. Rio de Janeiro: Cultura Médica; 2003.
-
(2003)
Cirurgia refrativa
-
-
-
3
-
-
28244461352
-
Análise da pressão intraocular após ceratectomia fotorrefrativa com excimer laser
-
Moura CR, Paranhos Júnior A, Grottone GT, Almeida PB, Mello PAA, Prata Júnior JA. Análise da pressão intraocular após ceratectomia fotorrefrativa com excimer laser. Arq Bras Oftalmol. 2000;63(2):107-10.
-
(2000)
Arq Bras Oftalmol
, vol.63
, Issue.2
, pp. 107-110
-
-
Moura, C.R.1
Paranhos Júnior, A.2
Grottone, G.T.3
Almeida, P.B.4
Mello, P.A.A.5
Prata Júnior, J.A.6
-
4
-
-
77049101017
-
Glaucoma e cirurgia refrativa
-
Costa VP. Glaucoma e cirurgia refrativa. Rev Bras Oftalmol. 2001;60(11):767-8.
-
(2001)
Rev Bras Oftalmol
, vol.60
, Issue.11
, pp. 767-768
-
-
Costa, V.P.1
-
5
-
-
77049092363
-
Avaliação da pressão intraocular com os tonômetros de não-contato, tono-pen e de Goldmann em olhos submetidos a Lasik para correção refrativa de miopia e astigmatismo miópico [tese]
-
Shinzato GT. Avaliação da pressão intraocular com os tonômetros de não-contato, tono-pen e de Goldmann em olhos submetidos a Lasik para correção refrativa de miopia e astigmatismo miópico [tese]. Belo Horizonte: Universidade Federal de Minas Gerais; 2000.
-
(2000)
Belo Horizonte: Universidade Federal de Minas Gerais
-
-
Shinzato, G.T.1
-
6
-
-
33745807801
-
Alteração da pressão intraocular aferida pela tonometria de aplanação após laser in situ keratomileusis
-
Fontes BM, Navajas EV, Melo Júnior LAS, Fontes MLM, Fontes PC. Alteração da pressão intraocular aferida pela tonometria de aplanação após laser in situ keratomileusis. Rev Bras Oftalmol. 2004;63(5/6):315-20.
-
(2004)
Rev Bras Oftalmol
, vol.63
, Issue.5-6
, pp. 315-320
-
-
Fontes, B.M.1
Navajas, E.V.2
Melo Júnior, L.A.S.3
Fontes, M.L.M.4
Fontes, P.C.5
-
7
-
-
0001526902
-
The coefficient of scleral rigidity in normal and glaucomatous eyes
-
Drance SM. The coefficient of scleral rigidity in normal and glaucomatous eyes. Arch Ophthalmol. 1960;63:668-74.
-
(1960)
Arch Ophthalmol
, vol.63
, pp. 668-674
-
-
Drance, S.M.1
-
8
-
-
72849158119
-
Tonometria (aplanação versus impressão) e coeficiente de rigidez escleral
-
Calixto N. Tonometria (aplanação versus impressão) e coeficiente de rigidez escleral. Rev Bras Oftalmol. 1961;20:49-72.
-
(1961)
Rev Bras Oftalmol
, vol.20
, pp. 49-72
-
-
Calixto, N.1
-
9
-
-
0012645577
-
Tonometer calibration; an attempt to remove discrepancies found in the 1954 calibration scale for Schioetz tonometers
-
Friedenwald JS. Tonometer calibration; an attempt to remove discrepancies found in the 1954 calibration scale for Schioetz tonometers. Trans Am Acad Ophthalmol Otolaryngol. 1957;61(1):108-22.
-
(1957)
Trans Am Acad Ophthalmol Otolaryngol
, vol.61
, Issue.1
, pp. 108-122
-
-
Friedenwald, J.S.1
-
10
-
-
0001063063
-
Contribution to the Ttheory and practice of tonometry
-
Friedenwald JS. Contribution to the Ttheory and practice of tonometry. Am J Ophthalmol. 1937;20:985-1024.
-
(1937)
Am J Ophthalmol
, vol.20
, pp. 985-1024
-
-
Friedenwald, J.S.1
-
12
-
-
77049102905
-
Examen funcional del ojo miope no glaucomatoso
-
Iguaçú/Brasil. Anais do II Simpósio Sudamericano de Glaucoma
-
Calixto NS. Examen funcional del ojo miope no glaucomatoso. In: II Simpósio Sudamericano de Glaucoma, 1980, Iguaçú/Brasil. Anais do II Simpósio Sudamericano de Glaucoma; 1980. v.1. p.84-97.
-
(1980)
II Simpósio Sudamericano de Glaucoma
, vol.1
, pp. 84-97
-
-
Calixto, N.S.1
-
13
-
-
13844317424
-
Corneal power, thickness, and stiffness: Results of a prospective randomized controlled trial of PRK and LASIK for myopia
-
Hjortdal JO, Moller-Pedersen T, Ivarsen A, Ehlers N. Corneal power, thickness, and stiffness: Results of a prospective randomized controlled trial of PRK and LASIK for myopia. J Cataract Refract Surg. 2005;31(1):21-9.
-
(2005)
J Cataract Refract Surg
, vol.31
, Issue.1
, pp. 21-29
-
-
Hjortdal, J.O.1
Moller-Pedersen, T.2
Ivarsen, A.3
Ehlers, N.4
-
14
-
-
33750591541
-
Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements
-
Martinez-de-la-Casa JM, Garcia-Feijoo J, Fernandez-Vidal A, Mendez-Hernandez C, Garcia-Sanchez J. Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements. Invest Ophthalmol Vis Sci. 2006;47(10):4410-4.
-
(2006)
Invest Ophthalmol Vis Sci
, vol.47
, Issue.10
, pp. 4410-4414
-
-
Martinez-de-la-Casa, J.M.1
Garcia-Feijoo, J.2
Fernandez-Vidal, A.3
Mendez-Hernandez, C.4
Garcia-Sanchez, J.5
-
15
-
-
33845227093
-
Corneal hysteresis and intraocular pressure measurement in children using the reichert ocular response analyzer
-
Erratum in: Am J Ophthalmol. 2007;144(4):642
-
Kirwan C, O'Keefe M, Lanigan B. Corneal hysteresis and intraocular pressure measurement in children using the reichert ocular response analyzer. Am J Ophthalmol. 2006;142(6):990-2. Erratum in: Am J Ophthalmol. 2007;144(4):642.
-
(2006)
Am J Ophthalmol
, vol.142
, Issue.6
, pp. 990992
-
-
Kirwan, C.1
O'Keefe, M.2
Lanigan, B.3
-
16
-
-
33845499055
-
Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry
-
Pepose JS, Feigenbaum SK, Qazi MA, Sanderson JP, Roberts CJ. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol. 2007;143(1):39-47.
-
(2007)
Am J Ophthalmol
, vol.143
, Issue.1
, pp. 39-47
-
-
Pepose, J.S.1
Feigenbaum, S.K.2
Qazi, M.A.3
Sanderson, J.P.4
Roberts, C.J.5
|