메뉴 건너뛰기




Volumn 31, Issue 6, 2010, Pages 2767-2775

Optimal design of customised hip prosthesis using fiber reinforced polymer composites

Author keywords

Fiber reinforced composites; Hip prosthesis; Optimization; Stiffness

Indexed keywords

BENDING STIFFNESS; COMPOSITE PROSTHESIS; COMPRESSIVE FORCES; ENGINEERING ALLOYS; FEMORAL PROSTHESIS; FIBER REINFORCED POLYMER COMPOSITES; FIBER-REINFORCED COMPOSITE; FIBER-REINFORCED COMPOSITES; FINITE ELEMENT PROGRAMS; HIP JOINTS; IMPLANT MATERIALS; LONGITUDINAL DIRECTION; MATRIX; METALLIC ALLOYS; NEW MATERIAL; NUMERICAL OPTIMIZATIONS; OPTIMAL DESIGN; OPTIMIZATION ALGORITHMS; ORTHOPAEDIC SURGERY; RADIAL DIRECTION; STIFFNESS PROPERTIES; STRESS SHIELDING;

EID: 76949094134     PISSN: 02641275     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.matdes.2010.01.016     Document Type: Article
Times cited : (31)

References (27)
  • 2
    • 0032971989 scopus 로고    scopus 로고
    • Effect of stem stiffness and bone stiffness on bone remodeling in cemented total hip replacement
    • Wan Z., Dorr L.D., Woodsome T., Ranawat A., and Song M. Effect of stem stiffness and bone stiffness on bone remodeling in cemented total hip replacement. J Arthoplasty 14 (1999) 149-158
    • (1999) J Arthoplasty , vol.14 , pp. 149-158
    • Wan, Z.1    Dorr, L.D.2    Woodsome, T.3    Ranawat, A.4    Song, M.5
  • 3
    • 0027690082 scopus 로고
    • Fracture mechanics of bone
    • Melvin J.W. Fracture mechanics of bone. J Biomech Eng 115 (1993) 549-554
    • (1993) J Biomech Eng , vol.115 , pp. 549-554
    • Melvin, J.W.1
  • 4
    • 70349145005 scopus 로고    scopus 로고
    • Novel carbon fiber composite for hip replacement with improved in vitro and in vivo osteointegration
    • Dimitrievska S., Whitfiled J., Hacking S.A., and Bureau M.N. Novel carbon fiber composite for hip replacement with improved in vitro and in vivo osteointegration. J Biomed Mater Res, Part A 91A 1 (2008) 37-51
    • (2008) J Biomed Mater Res, Part A , vol.91 A , Issue.1 , pp. 37-51
    • Dimitrievska, S.1    Whitfiled, J.2    Hacking, S.A.3    Bureau, M.N.4
  • 7
    • 0033874840 scopus 로고    scopus 로고
    • Design of a controlled-stiffness composite proximal femoral prosthesis
    • Simoes J.A., Marques A.T., and Jeronimidis G. Design of a controlled-stiffness composite proximal femoral prosthesis. Compos Sci Technol 60 (2000) 559-567
    • (2000) Compos Sci Technol , vol.60 , pp. 559-567
    • Simoes, J.A.1    Marques, A.T.2    Jeronimidis, G.3
  • 8
    • 0032201988 scopus 로고    scopus 로고
    • Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement
    • Wang A., Lin L., Polineni V.K., Essner A., Stark C., and Dumbleton J.H. Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement. Tribol Int 31 11 (1998) 661-667
    • (1998) Tribol Int , vol.31 , Issue.11 , pp. 661-667
    • Wang, A.1    Lin, L.2    Polineni, V.K.3    Essner, A.4    Stark, C.5    Dumbleton, J.H.6
  • 9
    • 0036325073 scopus 로고    scopus 로고
    • Progressive failure analysis of laminated composite femoral prostheses for total hip arthroplasty
    • Li C., Granger C., Schutte H.D., Biggers S.B., Kennedy J.M., and Latour R.A. Progressive failure analysis of laminated composite femoral prostheses for total hip arthroplasty. Biomaterials 23 (2002) 4249-4262
    • (2002) Biomaterials , vol.23 , pp. 4249-4262
    • Li, C.1    Granger, C.2    Schutte, H.D.3    Biggers, S.B.4    Kennedy, J.M.5    Latour, R.A.6
  • 10
    • 0034308352 scopus 로고    scopus 로고
    • Structural response and relative strength of a laminated composite hip prosthesis: effects of functional activity
    • Srinivasan S., Andrade J.R., Biggers S.B., and Latour R.A. Structural response and relative strength of a laminated composite hip prosthesis: effects of functional activity. Biomaterials 21 (2000) 1929-1940
    • (2000) Biomaterials , vol.21 , pp. 1929-1940
    • Srinivasan, S.1    Andrade, J.R.2    Biggers, S.B.3    Latour, R.A.4
  • 11
    • 84987590235 scopus 로고
    • Performance of characterization and modeling of a composite HIP prosthesis
    • Liao K. Performance of characterization and modeling of a composite HIP prosthesis. Exp Tech 18 5 (1994) 33-38
    • (1994) Exp Tech , vol.18 , Issue.5 , pp. 33-38
    • Liao, K.1
  • 13
    • 33846419572 scopus 로고    scopus 로고
    • Fabrication and properties of graded composite rods for biomedical applications
    • Boss J.N., and Ganesh V.K. Fabrication and properties of graded composite rods for biomedical applications. Compos Struct 74 (2006) 289-293
    • (2006) Compos Struct , vol.74 , pp. 289-293
    • Boss, J.N.1    Ganesh, V.K.2
  • 14
    • 0030627449 scopus 로고    scopus 로고
    • Composite hip prosthesis design - I analysis
    • Yildiz H., Ha S.K., and Chang F.K. Composite hip prosthesis design - I analysis. J Biomed Mater Res, Part A 39A 1 (1998) 92-101
    • (1998) J Biomed Mater Res, Part A , vol.39 A , Issue.1 , pp. 92-101
    • Yildiz, H.1    Ha, S.K.2    Chang, F.K.3
  • 16
    • 0032442899 scopus 로고    scopus 로고
    • Bone size and mechanics at the femoral diaphysis across age and sex
    • Stein M.S., Thomas C.D., Feik S.A., Wark J.D., and Clement J.G. Bone size and mechanics at the femoral diaphysis across age and sex. J Biomech 31 (1998) 1101-1110
    • (1998) J Biomech , vol.31 , pp. 1101-1110
    • Stein, M.S.1    Thomas, C.D.2    Feik, S.A.3    Wark, J.D.4    Clement, J.G.5
  • 17
    • 0034989298 scopus 로고    scopus 로고
    • Hip joint and abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction
    • Stolk J., Verdonschot N., and Huiskes R. Hip joint and abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction. J Biomech 34 (2001) 917-926
    • (2001) J Biomech , vol.34 , pp. 917-926
    • Stolk, J.1    Verdonschot, N.2    Huiskes, R.3
  • 18
    • 0034983758 scopus 로고    scopus 로고
    • Normal hip joint contact pressure distribution in single-leg standing - effect of gender and anatomic parameters
    • Genda E., Iwasaki N., Li G., MacWilliams B.A., Barrance P.J., and Chao E.Y.S. Normal hip joint contact pressure distribution in single-leg standing - effect of gender and anatomic parameters. J Biomech 34 (2001) 895-905
    • (2001) J Biomech , vol.34 , pp. 895-905
    • Genda, E.1    Iwasaki, N.2    Li, G.3    MacWilliams, B.A.4    Barrance, P.J.5    Chao, E.Y.S.6
  • 19
    • 76949098520 scopus 로고
    • Guidelines based on an engineering analysis of a special femur implant fixation
    • Ghista D.N., and Roaf R. (Eds), Academic Press, New York
    • Hayes S.V., and Sneath R.S. Guidelines based on an engineering analysis of a special femur implant fixation. In: Ghista D.N., and Roaf R. (Eds). Orthopaedic mechanics: procedures and devices vol. III (1981), Academic Press, New York
    • (1981) Orthopaedic mechanics: procedures and devices , vol.III
    • Hayes, S.V.1    Sneath, R.S.2
  • 21
    • 0034812287 scopus 로고    scopus 로고
    • Material optimization of femoral component of total hip prosthesis using fiber reinforced polymeric composites
    • Katoozian H., Davy D.T., Arshi A., and Saadati U. Material optimization of femoral component of total hip prosthesis using fiber reinforced polymeric composites. Med Eng Phys 23 7 (2001) 503-509
    • (2001) Med Eng Phys , vol.23 , Issue.7 , pp. 503-509
    • Katoozian, H.1    Davy, D.T.2    Arshi, A.3    Saadati, U.4
  • 25
    • 0242608383 scopus 로고    scopus 로고
    • Finite element simulation of the hip joint during stumbling: a comparison between static and dynamic loading
    • El'Sheikh H.F., MacDonald B.J., and Hashmi M.S.J. Finite element simulation of the hip joint during stumbling: a comparison between static and dynamic loading. J Mater Process Technol 143-144 (2003) 249-255
    • (2003) J Mater Process Technol , vol.143-144 , pp. 249-255
    • El'Sheikh, H.F.1    MacDonald, B.J.2    Hashmi, M.S.J.3
  • 26
    • 39049099651 scopus 로고    scopus 로고
    • Performance of CF/PA12 composite femoral stems
    • Campbell M., Bureau M.N., and Yahia L. Performance of CF/PA12 composite femoral stems. J Mater Sci: Mater Med 19 2 (2008) 683-693
    • (2008) J Mater Sci: Mater Med , vol.19 , Issue.2 , pp. 683-693
    • Campbell, M.1    Bureau, M.N.2    Yahia, L.3
  • 27
    • 0032124310 scopus 로고    scopus 로고
    • The effect of hip stem material modulus on surface strain in human femora
    • Vail T.P., Glisson R.R., Koukoubis T.D., and Guilak F. The effect of hip stem material modulus on surface strain in human femora. J Biomech 31 (1998) 619-628
    • (1998) J Biomech , vol.31 , pp. 619-628
    • Vail, T.P.1    Glisson, R.R.2    Koukoubis, T.D.3    Guilak, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.