Volumn 33, Issue 1, 2010, Pages 28-35

Evaluation of the risk of transmission of bacterial biofilms and Clostridium difficile during gastrointestinal endoscopy

Author keywords

[No Author keywords available]

Indexed keywords

BACTERIAL COUNT; BIOFILM; CLOSTRIDIUM DIFFICILE; CLOSTRIDIUM INFECTION; CROSS INFECTION; DISEASE TRANSMISSION; DISINFECTION; EQUIPMENT; GASTROINTESTINAL ENDOSCOPE; GROWTH, DEVELOPMENT AND AGING; HUMAN; INFECTION CONTROL; MICROBIOLOGY; PRACTICE GUIDELINE; REVIEW; RISK ASSESSMENT; RISK FACTOR; STATISTICS;

EID: 76849112680     PISSN: 1042895X     EISSN: 15389766     Source Type: Journal    
DOI: 10.1097/SGA.0b013e3181cd199f     Document Type: Article
Times cited : (13)

References (37)
  • 1
    • 35349027843 scopus 로고    scopus 로고
    • Rapid communication: Effects of Steris 1 sterilization and Cidex ortho-phthalaldehyde high-level disinfection on durability of new-generation flexible ureteroscopes
    • Abraham, J. B., Abdelshehid, C. S., Lee, H. J., Box, G. N., Deane, L. A., Le, T., et al. (2007). Rapid communication: Effects of Steris 1 sterilization and Cidex ortho-phthalaldehyde high-level disinfection on durability of new-generation flexible ureteroscopes. Journal of Endourology, 21(9), 985-992.
    • (2007) Journal of Endourology , vol.21 , Issue.9 , pp. 985-992
    • Abraham, J.B.1    Abdelshehid, C.S.2    Lee, H.J.3    Box, G.N.4    Deane, L.A.5    Le, T.6
  • 2
    • 66949164844 scopus 로고    scopus 로고
    • Modeling microbial survival in buildup biofilm for complex medical devices
    • Alfa, M. J., & Howie, R. (2009). Modeling microbial survival in buildup biofilm for complex medical devices. BMC Infectious Diseases, 9, 56.
    • (2009) BMC Infectious Diseases , vol.9 , pp. 56
    • Alfa, M.J.1    Howie, R.2
  • 3
    • 0025992682 scopus 로고
    • Nosocomial infections from contaminated endoscopes: A flawed automated endoscope washer. An investigation using molecular epidemiology
    • Alvarado, C. J., Stolz, S. M., & Maki, D. G. (1991). Nosocomial infections from contaminated endoscopes: A flawed automated endoscope washer. An investigation using molecular epidemiology. American Journal of Medicine, 91(3), S272S-S280S.
    • (1991) American Journal of Medicine , vol.91 , Issue.3
    • Alvarado, C.J.1    Stolz, S.M.2    Maki, D.G.3
  • 4
    • 0033041917 scopus 로고    scopus 로고
    • Infection control during gastrointestinal endoscopy
    • American Society for Gastrointestinal Endoscopy
    • American Society for Gastrointestinal Endoscopy. (1999). Infection control during gastrointestinal endoscopy. Gastrointestinal Endoscopy, 49(6), 836-841.
    • (1999) Gastrointestinal Endoscopy , vol.49 , Issue.6 , pp. 836-841
  • 5
    • 42749089464 scopus 로고    scopus 로고
    • Infection control during GI endoscopy
    • American Society for Gastrointestinal Endoscopy
    • American Society for Gastrointestinal Endoscopy. (2008). Infection control during GI endoscopy. Gastrointestinal Endoscopy, 67(6), 781-790.
    • (2008) Gastrointestinal Endoscopy , vol.67 , Issue.6 , pp. 781-790
  • 6
    • 33744810095 scopus 로고    scopus 로고
    • A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failure
    • Bisset, L., Cossart, Y. E., Selby, W., West, R., Catterson, D., O'hara, K., et al. (2006). A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failure. American Journal of Infection Control, 34(5), 274-280.
    • (2006) American Journal of Infection Control , vol.34 , Issue.5 , pp. 274-280
    • Bisset, L.1    Cossart, Y.E.2    Selby, W.3    West, R.4    Catterson, D.5    O'Hara, K.6
  • 7
    • 34147159375 scopus 로고    scopus 로고
    • The Steris Reliance EPS endoscope processing system. A new automated endoscope reprocessing technology
    • ECRI Institute
    • ECRI Institute. (2007). The Steris Reliance EPS endoscope processing system. A new automated endoscope reprocessing technology. Health Devices, 32(1), 22-31.
    • (2007) Health Devices , vol.32 , Issue.1 , pp. 22-31
  • 8
    • 0343990780 scopus 로고    scopus 로고
    • Liquid sterilization versus high level disinfection in the urologic office
    • Fuselier, H. A., & Mason, C. (1997). Liquid sterilization versus high level disinfection in the urologic office. Urology, 50(3), 337-340.
    • (1997) Urology , vol.50 , Issue.3 , pp. 337-340
    • Fuselier, H.A.1    Mason, C.2
  • 9
    • 0034741580 scopus 로고    scopus 로고
    • Pseudo-outbreak of Mycobacterium chelonae and Methylobacterium mesophilicum caused by contamination of an automated endoscopy washer
    • Kressel, A. B., & Kidd, F. (2001). Pseudo-outbreak of Mycobacterium chelonae and Methylobacterium mesophilicum caused by contamination of an automated endoscopy washer. Infection Control & Hospital Epidemiology, 22(7), 414-418.
    • (2001) Infection Control & Hospital Epidemiology , vol.22 , Issue.7 , pp. 414-418
    • Kressel, A.B.1    Kidd, F.2
  • 10
    • 0002522022 scopus 로고    scopus 로고
    • A sterilization standard for endoscopes and other difficult to clean medical devices
    • 42-52,54-56
    • Lewis, D. (1999). A sterilization standard for endoscopes and other difficult to clean medical devices. Practical Gastroenterology, 23(9), 28-36,42-52,54-56.
    • (1999) Practical Gastroenterology , vol.23 , Issue.9 , pp. 28-36
    • Lewis, D.1
  • 11
    • 33750533198 scopus 로고    scopus 로고
    • Bacterial biofilms within the clinical setting: What healthcare professionals should know
    • DOI 10.1016/j.jhin.2006.06.028, PII S0195670106003355
    • Lindsay, D., & von Holy, A. (2006). Bacterial biofilms within the clinical setting: What healthcare professionals should know. Journal of Hospital Infection, 64(4), 313-325. (Pubitemid 44661034)
    • (2006) Journal of Hospital Infection , vol.64 , Issue.4 , pp. 313-325
    • Lindsay, D.1    Von Holy, A.2
  • 12
    • 33750616073 scopus 로고    scopus 로고
    • Using an efficient biofilm detaching agent: An essential step for the improvement of endoscope reprocessing protocols
    • Marion, K., Freney, J., James, G., Bergeron, E., Renaud, F. N., & Costerton, J. W. (2006). Using an efficient biofilm detaching agent: An essential step for the improvement of endoscope reprocessing protocols. Journal of Hospital Infection, 64(2), 136-142.
    • (2006) Journal of Hospital Infection , vol.64 , Issue.2 , pp. 136-142
    • Marion, K.1    Freney, J.2    James, G.3    Bergeron, E.4    Renaud, F.N.5    Costerton, J.W.6
  • 14
    • 34548316269 scopus 로고    scopus 로고
    • Sporicidal activity of disinfectants as one possible cause for bacteria in patientready endoscopes
    • Miner, N., Harris, V., Ebron, T., & Cao, T. D. (2007). Sporicidal activity of disinfectants as one possible cause for bacteria in patientready endoscopes. Gastroenterology Nursing, 30(4), 285-290.
    • (2007) Gastroenterology Nursing , vol.30 , Issue.4 , pp. 285-290
    • Miner, N.1    Harris, V.2    Ebron, T.3    Cao, T.D.4
  • 15
    • 0030097079 scopus 로고    scopus 로고
    • High-level disinfection or "sterilization" of endoscopes?
    • Muscarella, L. F. (1996). High-level disinfection or " sterilization" of endoscopes? Infection Control & Hospital Epidemiology, 17(3), 183-187.
    • (1996) Infection Control & Hospital Epidemiology , vol.17 , Issue.3 , pp. 183-187
    • Muscarella, L.F.1
  • 16
    • 0033156291 scopus 로고    scopus 로고
    • Do scopes spread sickness?
    • Commentary
    • Muscarella, L. F. (1999). Commentary. "Do scopes spread sickness?" Gastroenterology Nursing, 22(4), 179-180.
    • (1999) Gastroenterology Nursing , vol.22 , Issue.4 , pp. 179-180
    • Muscarella, L.F.1
  • 17
    • 14744280800 scopus 로고    scopus 로고
    • The risk of disease transmission during gastrointestinal endoscopy
    • Dear Los Angeles Times
    • Muscarella, L. F. (2004). Dear Los Angeles Times. The risk of disease transmission during gastrointestinal endoscopy. Gastroenterology Nursing, 27(6), 271-278.
    • (2004) Gastroenterology Nursing , vol.27 , Issue.6 , pp. 271-278
    • Muscarella, L.F.1
  • 18
    • 85058720700 scopus 로고    scopus 로고
    • The importance of bronchoscope reprocessing guidelines: Raising the standard of care
    • Muscarella, L. F. (2004). The importance of bronchoscope reprocessing guidelines: Raising the standard of care. Chest, 126(3), 1001-1003.
    • (2004) Chest , vol.126 , Issue.3 , pp. 1001-1003
    • Muscarella, L.F.1
  • 19
    • 33748440614 scopus 로고    scopus 로고
    • Inconsistencies in endoscope-reprocessing and infection-control guidelines: The importance of endoscope drying
    • Muscarella, L. F. (2006). Inconsistencies in endoscope-reprocessing and infection-control guidelines: The importance of endoscope drying. American Journal of Gastroenterology, 101(9), 2147-2154.
    • (2006) American Journal of Gastroenterology , vol.101 , Issue.9 , pp. 2147-2154
    • Muscarella, L.F.1
  • 20
    • 39049097599 scopus 로고    scopus 로고
    • Reassessment of the risk of health careacquired infection during rigid laryngoscopy
    • Muscarella, L. F. (2008). Reassessment of the risk of healthcareacquired infection during rigid laryngoscopy. Journal of Hospital Infection, 68(2), 101-107.
    • (2008) Journal of Hospital Infection , vol.68 , Issue.2 , pp. 101-107
    • Muscarella, L.F.1
  • 21
    • 76849103031 scopus 로고    scopus 로고
    • Endoscopic disinfection
    • T. M. Bayless & A. M. Diehl (Eds.), (5th ed., pp. 23-28). Hamilton, Ontario, Canada: B. C. Decker
    • Muscarella, L. F., & DiMarino, A. J. (2005). Endoscopic disinfection. In T. M. Bayless & A. M. Diehl (Eds.), Advanced therapy in gastroenterology and liver disease (5th ed., pp. 23-28). Hamilton, Ontario, Canada: B. C. Decker.
    • (2005) Advanced Therapy in Gastroenterology and Liver Disease
    • Muscarella, L.F.1    Di Marino, A.J.2
  • 22
    • 0038784126 scopus 로고    scopus 로고
    • Infectious disease complications of GI endoscopy: Part II, exogenous infections
    • Nelson, D. B. (2003). Infectious disease complications of GI endoscopy: Part II, exogenous infections. Gastrointestinal Endoscopy, 57(6), 695-711.
    • (2003) Gastrointestinal Endoscopy , vol.57 , Issue.6 , pp. 695-711
    • Nelson, D.B.1
  • 24
    • 33746256649 scopus 로고    scopus 로고
    • Current issues in endoscope reprocessing and infection control during gastrointestinal endoscopy
    • Nelson, D. B., & Muscarella, L. F. (2006). Current issues in endoscope reprocessing and infection control during gastrointestinal endoscopy. World Journal of Gastroenterology, 12(25), 3953-3964.
    • (2006) World Journal of Gastroenterology , vol.12 , Issue.25 , pp. 3953-3964
    • Nelson, D.B.1    Muscarella, L.F.2
  • 25
    • 7744243890 scopus 로고    scopus 로고
    • Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination?
    • Pajkos, A., Vickery, K., & Cossart, Y. (2004). Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination? Journal of Hospital Infection, 58(3), 224-229.
    • (2004) Journal of Hospital Infection , vol.58 , Issue.3 , pp. 224-229
    • Pajkos, A.1    Vickery, K.2    Cossart, Y.3
  • 26
    • 40649086370 scopus 로고    scopus 로고
    • Efficient removal of attached biofilm in a naturally contaminated colonoscope using detachment-promoting agents
    • Perret-Vivancos, C., Marion, K., Renaud, F. N., & Freney, J. (2008). Efficient removal of attached biofilm in a naturally contaminated colonoscope using detachment-promoting agents. Journal of Hospital Infection, 68(3), 277-278.
    • (2008) Journal of Hospital Infection , vol.68 , Issue.3 , pp. 277-278
    • Perret-Vivancos, C.1    Marion, K.2    Renaud, F.N.3    Freney, J.4
  • 27
    • 3142680740 scopus 로고    scopus 로고
    • Clostridium difficile-associated diarrhea in adults
    • Poutanen, S. M., & Simor, A. E. (2004). Clostridium difficile-associated diarrhea in adults. Canadian Medical Association Journal, 171(1), 51-58.
    • (2004) Canadian Medical Association Journal , vol.171 , Issue.1 , pp. 51-58
    • Poutanen, S.M.1    Simor, A.E.2
  • 29
    • 33751333068 scopus 로고    scopus 로고
    • Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices
    • Sattar, S. A., Kibbee, R. J., Tetro, J. A., & Rook, T. A. (2006). Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices. Infection Control & Hospital Epidemiology, 27(11), 1193-1199.
    • (2006) Infection Control & Hospital Epidemiology , vol.27 , Issue.11 , pp. 1193-1199
    • Sattar, S.A.1    Kibbee, R.J.2    Tetro, J.A.3    Rook, T.A.4
  • 31
    • 0034231418 scopus 로고    scopus 로고
    • Standards of infection control in reprocessing of flexible gastrointestinal endoscopes
    • Society of Gastroenterology Nurses and Associates
    • Society of Gastroenterology Nurses and Associates. (2000). Standards of infection control in reprocessing of flexible gastrointestinal endoscopes. Gastroenterology Nursing, 23(4), 172-179.
    • (2000) Gastroenterology Nursing , vol.23 , Issue.4 , pp. 172-179
  • 32
    • 33744996516 scopus 로고    scopus 로고
    • Standards of infection control in reprocessing of flexible gastrointestinal endoscopes
    • Society of Gastroenterology Nurses and Associates
    • Society of Gastroenterology Nurses and Associates. (2006). Standards of infection control in reprocessing of flexible gastrointestinal endoscopes. Gastroenterology Nursing, 29(2), 142-148.
    • (2006) Gastroenterology Nursing , vol.29 , Issue.2 , pp. 142-148
  • 34
    • 0033089903 scopus 로고    scopus 로고
    • Do scopes spread sickness?
    • (March 1)
    • Underwood, A. (1999, March 1). Do scopes spread sickness? Newsweek, 133(9), 72-73.
    • (1999) Newsweek , vol.133 , Issue.9 , pp. 72-73
    • Underwood, A.1
  • 35
    • 67651160862 scopus 로고    scopus 로고
    • The effects of multiple cycles of contamination, detergent washing, and disinfection on the development of biofilm in endoscope tubing
    • Vickery, K., Ngo, Q. D., Zou, J., & Cossart, Y. E. (2009). The effects of multiple cycles of contamination, detergent washing, and disinfection on the development of biofilm in endoscope tubing. American Journal of Infection Control, 37(6), 470-475.
    • (2009) American Journal of Infection Control , vol.37 , Issue.6 , pp. 470-475
    • Vickery, K.1    Ngo, Q.D.2    Zou, J.3    Cossart, Y.E.4
  • 36
    • 2442427548 scopus 로고    scopus 로고
    • Removal of biofilm from endoscopes: Evaluation of detergent efficiency
    • Vickery, K., Pajkos, A., Cossart, Y. (2004). Removal of biofilm from endoscopes: evaluation of detergent efficiency. American Journal of Infection Control, 32(3), 170-176.
    • (2004) American Journal of Infection Control , vol.32 , Issue.3 , pp. 170-176
    • Vickery, K.1    Pajkos, A.2    Cossart, Y.3
  • 37
    • 76849106578 scopus 로고    scopus 로고
    • Whitely Corporation, September, North Sydney, NSW, Australia: Author
    • Whitely Corporation. (2003, September). Technical bulletin: Matrix biofilm remover (pp. 1-10). North Sydney, NSW, Australia: Author.
    • (2003) Technical Bulletin: Matrix Biofilm Remover , pp. 1-10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.