메뉴 건너뛰기




Volumn 21, Issue 9, 2007, Pages 985-992

Rapid communication: Effects of Steris 1™ sterilization and Cidex® ortho-phthalaldehyde high-level disinfection on durability of new-generation flexible ureteroscopes

Author keywords

[No Author keywords available]

Indexed keywords

GLUTARALDEHYDE; PHTHALALDEHYDE;

EID: 35349027843     PISSN: 08927790     EISSN: None     Source Type: Journal    
DOI: 10.1089/end.2007.0181     Document Type: Article
Times cited : (32)

References (27)
  • 1
    • 0000684156 scopus 로고
    • Fiber optics in urology
    • Marshall VF. Fiber optics in urology. J Urol 1964;91:110-114.
    • (1964) J Urol , vol.91 , pp. 110-114
    • Marshall, V.F.1
  • 2
    • 0015165593 scopus 로고
    • Clinical application of fiber-optic ureteropyeloscopy
    • Takayasu H, Aso Y, Takagi T, Go T. Clinical application of fiber-optic ureteropyeloscopy. Urol Int 1971;26:97-104.
    • (1971) Urol Int , vol.26 , pp. 97-104
    • Takayasu, H.1    Aso, Y.2    Takagi, T.3    Go, T.4
  • 5
    • 0041622709 scopus 로고    scopus 로고
    • Evaluation of overall costs of currently available small flexible ureteroscopes
    • Landman J, Lee DI, Lee C, Monga M. Evaluation of overall costs of currently available small flexible ureteroscopes. Urology 2003;62:218-222.
    • (2003) Urology , vol.62 , pp. 218-222
    • Landman, J.1    Lee, D.I.2    Lee, C.3    Monga, M.4
  • 6
    • 29244483694 scopus 로고    scopus 로고
    • Evaluation of the mechanisms of damage to flexible ureteroscopes and suggestions for ureteroscope preservation
    • Sooriakumaran P, Kaba R, Andrews HO, Buchholz PN. Evaluation of the mechanisms of damage to flexible ureteroscopes and suggestions for ureteroscope preservation. Asian J Androl 2005;7:433-438.
    • (2005) Asian J Androl , vol.7 , pp. 433-438
    • Sooriakumaran, P.1    Kaba, R.2    Andrews, H.O.3    Buchholz, P.N.4
  • 7
    • 33744787602 scopus 로고    scopus 로고
    • Durability of flexible ureteroscopes: A randomized, prospective study
    • Monga M, Best S, Venkatesh R, et al. Durability of flexible ureteroscopes: A randomized, prospective study. J Urol 2006;176:137-141.
    • (2006) J Urol , vol.176 , pp. 137-141
    • Monga, M.1    Best, S.2    Venkatesh, R.3
  • 8
    • 0034822949 scopus 로고    scopus 로고
    • Does the cleaning technique influence the durability of the <9F flexible ureteroscope?
    • McDougall EM, Alberts G, Deal KJ, Nagy JM. Does the cleaning technique influence the durability of the <9F flexible ureteroscope? J Endourol 2001;15:615-618.
    • (2001) J Endourol , vol.15 , pp. 615-618
    • McDougall, E.M.1    Alberts, G.2    Deal, K.J.3    Nagy, J.M.4
  • 13
    • 0343990780 scopus 로고    scopus 로고
    • Liquid sterilization versus high-level disinfection in the urologic office
    • Fuselier HA Jr, Mason C. Liquid sterilization versus high-level disinfection in the urologic office. Urology 1997;50:337-340.
    • (1997) Urology , vol.50 , pp. 337-340
    • Fuselier Jr, H.A.1    Mason, C.2
  • 14
    • 33646313551 scopus 로고    scopus 로고
    • New sterilization system cuts repair costs for rigid scopes
    • Heller J. New sterilization system cuts repair costs for rigid scopes. Materials Management 1996;70.
    • (1996) Materials Management , pp. 70
    • Heller, J.1
  • 15
    • 0029738949 scopus 로고    scopus 로고
    • APIC Guidelines for Infection Control Practice
    • Rutala WA. APIC Guidelines for Infection Control Practice. Am J Infect Control 1996;24:313-342.
    • (1996) Am J Infect Control , vol.24 , pp. 313-342
    • Rutala, W.A.1
  • 17
    • 0034919807 scopus 로고    scopus 로고
    • Evaluation of the microbial efficacy of Steris System I for digestive endoscopes using GERMANDE and ASTM validation protocols
    • Luu Duc D, Ribiollet A, Dode X, Ducel G, Marchetti B, Calop J. Evaluation of the microbial efficacy of Steris System I for digestive endoscopes using GERMANDE and ASTM validation protocols. J Hosp Infect 2001;48:135-141.
    • (2001) J Hosp Infect , vol.48 , pp. 135-141
    • Luu Duc, D.1    Ribiollet, A.2    Dode, X.3    Ducel, G.4    Marchetti, B.5    Calop, J.6
  • 18
    • 0027954617 scopus 로고
    • In-hospital evaluation of orthophthalaldehyde as a high level disinfectant for flexible endoscopes
    • Alfa MJ, Sitter DL. In-hospital evaluation of orthophthalaldehyde as a high level disinfectant for flexible endoscopes. J Hosp Infect 1994;26:15-26.
    • (1994) J Hosp Infect , vol.26 , pp. 15-26
    • Alfa, M.J.1    Sitter, D.L.2
  • 19
    • 0036150450 scopus 로고    scopus 로고
    • Effects of different disinfection and sterilization methods on tensile strength of materials used for single-use devices
    • Brown SA, Merritt K, Woods TO, McNamee SG, Hitchins VM. Effects of different disinfection and sterilization methods on tensile strength of materials used for single-use devices. Biomed Instrum Technol 2002;36:23-27.
    • (2002) Biomed Instrum Technol , vol.36 , pp. 23-27
    • Brown, S.A.1    Merritt, K.2    Woods, T.O.3    McNamee, S.G.4    Hitchins, V.M.5
  • 20
    • 0141923526 scopus 로고    scopus 로고
    • An evaluation of Cidex OPA (0.55% ortho-phthalaldehyde) as an alternative to 2% glutaraldehyde for high-level disinfection of endoscopes
    • Cooke RP, Goddard SV, Whymant-Morris A, Sherwood J, Chatterly R. An evaluation of Cidex OPA (0.55% ortho-phthalaldehyde) as an alternative to 2% glutaraldehyde for high-level disinfection of endoscopes. J Hosp Inf 2003;54:226-231.
    • (2003) J Hosp Inf , vol.54 , pp. 226-231
    • Cooke, R.P.1    Goddard, S.V.2    Whymant-Morris, A.3    Sherwood, J.4    Chatterly, R.5
  • 21
    • 4344609711 scopus 로고    scopus 로고
    • Nine episodes of anaphylaxis following cystoscopy using Cidex OPA (ortho-phthalaldehyde) high-level disinfectant in 4 patients after cystoscopy
    • Sokol WN. Nine episodes of anaphylaxis following cystoscopy using Cidex OPA (ortho-phthalaldehyde) high-level disinfectant in 4 patients after cystoscopy. J Allergy Clin Immunol 2004;114:392-397.
    • (2004) J Allergy Clin Immunol , vol.114 , pp. 392-397
    • Sokol, W.N.1
  • 22
    • 35348947184 scopus 로고    scopus 로고
    • Two cases of ortho-phthalaldehyde induced allergic reactions in patients undergoing surveillance cystoscopy
    • Joshi SN and Rosenfeld S. Two cases of ortho-phthalaldehyde induced allergic reactions in patients undergoing surveillance cystoscopy. J Allergy Clin Immunol 2004;113:S311.
    • (2004) J Allergy Clin Immunol , vol.113
    • Joshi, S.N.1    Rosenfeld, S.2
  • 23
    • 1942516358 scopus 로고    scopus 로고
    • Reprocessing endoscopes: United States perspective
    • Rutala WA, Weber DJ. Reprocessing endoscopes: United States perspective. J Hosp Infect 2004;56:S27-S39.
    • (2004) J Hosp Infect , vol.56
    • Rutala, W.A.1    Weber, D.J.2
  • 24
    • 33750626250 scopus 로고    scopus 로고
    • A new peroxide-based flexible endoscope-compatible high-level disinfectant
    • Omidbakhsh N. A new peroxide-based flexible endoscope-compatible high-level disinfectant. Am J Infect Control 2006;34:571-577.
    • (2006) Am J Infect Control , vol.34 , pp. 571-577
    • Omidbakhsh, N.1
  • 25
    • 85058249504 scopus 로고    scopus 로고
    • Importance of lumen flow in liquid chemical sterilization
    • Alfa MJ. Importance of lumen flow in liquid chemical sterilization. Am J Infect Control 1999;27:373-374.
    • (1999) Am J Infect Control , vol.27 , pp. 373-374
    • Alfa, M.J.1
  • 26
    • 0030097079 scopus 로고    scopus 로고
    • High-level disinfection or "sterilization" of endoscopes?
    • Muscarella LF. High-level disinfection or "sterilization" of endoscopes? Infect Control Hosp Epidemiol 1996;17:183-187.
    • (1996) Infect Control Hosp Epidemiol , vol.17 , pp. 183-187
    • Muscarella, L.F.1
  • 27
    • 21044448036 scopus 로고    scopus 로고
    • Comparison of flexible ureteroscopes: Deflection, irrigant flow and optical characteristics
    • Abdelshehid C, Ahlering MT, Chou D, et al. Comparison of flexible ureteroscopes: Deflection, irrigant flow and optical characteristics. J Urol 2005;173:2017-2021.
    • (2005) J Urol , vol.173 , pp. 2017-2021
    • Abdelshehid, C.1    Ahlering, M.T.2    Chou, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.