메뉴 건너뛰기




Volumn 33, Issue 1, 2010, Pages 31-37

Electrochemical aptasensor for tetracycline detection

Author keywords

Aptasensor; DNA aptamers; Electrochemical detection; Tetracycline

Indexed keywords

APTAMERS; DETECTION LIMITS; DNA APTAMERS; DOXYCYCLINE; DRINKING WATER; ELECTROCHEMICAL DETECTION; HIGH SELECTIVITY; MICROMOLAR RANGE; PHARMACEUTICAL PREPARATIONS; RECOGNITION ELEMENT; SCREEN-PRINTED GOLD ELECTRODE; SQUARE WAVE VOLTAMMETRY; STREPTAVIDIN; STRUCTURAL CHANGE;

EID: 76849110015     PISSN: 16157591     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00449-009-0371-4     Document Type: Article
Times cited : (168)

References (47)
  • 1
    • 0023155996 scopus 로고
    • Competition between tetracycline and tRNA at both P and A sites of the ribosome of Escherichia coli
    • DOI 10.1016/0014-5793(87)81539-9
    • B Epe P Woolley H Hornig 1987 Competition between tetracycline and tRNA at both P and A sites of the ribosome of Escherichia coli FEBS Lett 213 2 443 447 10.1016/0014-5793(87)81539-9 1:CAS:528:DyaL2sXktF2mtb4%3D (Pubitemid 17043931)
    • (1987) FEBS Letters , vol.213 , Issue.2 , pp. 443-447
    • Epe, B.1    Woolley, P.2    Hornig, H.3
  • 2
    • 0029745623 scopus 로고    scopus 로고
    • Throwing a spanner in the works: Antibiotics and the translation apparatus
    • 10.1007/BF00217518 1:CAS:528:DyaK28XltlWgs70%3D
    • CM Spahn CD Prescott 1996 Throwing a spanner in the works: antibiotics and the translation apparatus J Mol Med 74 8 423 439 10.1007/BF00217518 1:CAS:528:DyaK28XltlWgs70%3D
    • (1996) J Mol Med , vol.74 , Issue.8 , pp. 423-439
    • Spahn, C.M.1    Prescott, C.D.2
  • 3
    • 0037929546 scopus 로고    scopus 로고
    • Survey of residual tetracycline antibiotics and sulfa drugs in kidneys of diseased animals in the Aichi Prefecture, Japan (1995-1999)
    • 1:CAS:528:DC%2BD3sXkvFSmtro%3D
    • H Oka, et al. 2003 Survey of residual tetracycline antibiotics and sulfa drugs in kidneys of diseased animals in the Aichi Prefecture, Japan (1995-1999) J AOAC Int 86 3 494 500 1:CAS:528:DC%2BD3sXkvFSmtro%3D
    • (2003) J AOAC Int , vol.86 , Issue.3 , pp. 494-500
    • Oka, H.1
  • 4
    • 1542758397 scopus 로고    scopus 로고
    • Tetracycline residue levels in cattle meat from Nairobi salughter house in Kenya
    • 1:STN:280:DC%2BD3srjs1Sgsg%3D%3D
    • FK Muriuki, et al. 2001 Tetracycline residue levels in cattle meat from Nairobi salughter house in Kenya J Vet Sci 2 2 97 101 1:STN:280: DC%2BD3srjs1Sgsg%3D%3D
    • (2001) J Vet Sci , vol.2 , Issue.2 , pp. 97-101
    • Muriuki, F.K.1
  • 5
    • 0032444117 scopus 로고    scopus 로고
    • Detection of residues of tetracycline antibiotics in pork and chicken meat: Correlation between results of screening and confirmatory tests
    • DOI 10.1039/a804909b
    • K De Wasch, et al. 1998 Detection of residues of tetracycline antibiotics in pork and chicken meat: correlation between results of screening and confirmatory tests Analyst 123 12 2737 2741 10.1039/a804909b (Pubitemid 29027294)
    • (1998) Analyst , vol.123 , Issue.12 , pp. 2737-2741
    • De Wasch, K.1    Okerman, L.2    Croubels, S.3    De Brabander, H.4    Van Hoof, J.5    De Backer, P.6
  • 6
    • 0032619970 scopus 로고    scopus 로고
    • Determination of oxytetracycline, tetracycline, and chlortetracycline in milk by liquid chromatography with postcolumn derivatization and fluorescence detection
    • 1:CAS:528:DyaK1MXhtVCgtbo%3D
    • AL Pena CM Lino IN Silveira 1999 Determination of oxytetracycline, tetracycline, and chlortetracycline in milk by liquid chromatography with postcolumn derivatization and fluorescence detection J AOAC Int 82 1 55 60 1:CAS:528:DyaK1MXhtVCgtbo%3D
    • (1999) J AOAC Int , vol.82 , Issue.1 , pp. 55-60
    • Pena, A.L.1    Lino, C.M.2    Silveira, I.N.3
  • 7
    • 51249106181 scopus 로고    scopus 로고
    • Quantitative detection of tetracycline residues in honey by a simple sensitive immunoassay
    • 10.1016/j.aca.2008.08.003 1:CAS:528:DC%2BD1cXhtFemtbnF
    • M Jeon I Rhee Paeng 2008 Quantitative detection of tetracycline residues in honey by a simple sensitive immunoassay Anal Chim Acta 626 2 180 185 10.1016/j.aca.2008.08.003 1:CAS:528:DC%2BD1cXhtFemtbnF
    • (2008) Anal Chim Acta , vol.626 , Issue.2 , pp. 180-185
    • Jeon, M.1    Rhee Paeng, I.2
  • 8
    • 0030975372 scopus 로고    scopus 로고
    • Use of metal chelate affinity chromatography and membrane-based ion-exchange as clean-up procedure for trace residues analysis of tetracyclines in animal tissues and egg
    • DOI 10.1016/S0378-4347(96)00368-4, PII S0378434796003684
    • SM Croubels KE Vanoosthuyze CH van Peteghem 1997 Use of metal chelate affinity chromatography and membrane-based ion-exchange as clean-up procedure for trace residue analysis of tetracyclines in animal tissues and egg J Chromatogr B Biomed Sci Appl 690 1-2 173 179 10.1016/S0378-4347(96)00368-4 1:CAS:528:DyaK2sXhtlyiur8%3D (Pubitemid 27136467)
    • (1997) Journal of Chromatography B: Biomedical Applications , vol.690 , Issue.1-2 , pp. 173-179
    • Croubels, S.M.1    Vanoosthuyze, K.E.I.2    Van Peteghem, C.H.3
  • 9
    • 0020308205 scopus 로고
    • Can tetracycline-induced fatty liver in pregnancy be attributed to choline deficiency?
    • 10.1016/0306-9877(82)90131-1 1:CAS:528:DyaL38XlsFGlurk%3D
    • MC Gwee 1982 Can tetracycline-induced fatty liver in pregnancy be attributed to choline deficiency? Med Hypotheses 9 2 157 162 10.1016/0306-9877(82)90131-1 1:CAS:528:DyaL38XlsFGlurk%3D
    • (1982) Med Hypotheses , vol.9 , Issue.2 , pp. 157-162
    • Gwee, M.C.1
  • 10
    • 0034663887 scopus 로고    scopus 로고
    • Rapid liquid chromatographic method for simultaneous determination of tetracyclines antibiotics and 6-Epi-doxycycline in pharmaceutical products using porous graphitic carbon column
    • DOI 10.1016/S0731-7085(00)00329-0, PII S0731708500003290
    • L Monser F Darghouth 2000 Rapid liquid chromatographic method for simultaneous determination of tetracyclines antibiotics and 6-epi-doxycycline in pharmaceutical products using porous graphitic carbon column J Pharm Biomed Anal 23 2-3 353 362 10.1016/S0731-7085(00)00329-0 1:CAS:528:DC%2BD3cXlsFChtL0%3D (Pubitemid 30599448)
    • (2000) Journal of Pharmaceutical and Biomedical Analysis , vol.23 , Issue.2-3 , pp. 353-362
    • Monser, L.1    Darghouth, F.2
  • 11
    • 0141670515 scopus 로고    scopus 로고
    • HPLC separation of tetracycline analogues: Comparison study of laser-based polarimetric detection with UV detection
    • 1:CAS:528:DC%2BD3sXosF2gurY%3D
    • K Ng SW Linder 2003 HPLC separation of tetracycline analogues: comparison study of laser-based polarimetric detection with UV detection J Chromatogr Sci 41 9 460 466 1:CAS:528:DC%2BD3sXosF2gurY%3D
    • (2003) J Chromatogr Sci , vol.41 , Issue.9 , pp. 460-466
    • Ng, K.1    Linder, S.W.2
  • 12
    • 43949092097 scopus 로고    scopus 로고
    • Capillary electrophoretic method for the simultaneous determination of tetracycline residues in fish samples
    • 10.1016/j.jpba.2008.01.036 1:CAS:528:DC%2BD1cXmtlyitrw%3D
    • P Kowalski 2008 Capillary electrophoretic method for the simultaneous determination of tetracycline residues in fish samples J Pharm Biomed Anal 47 3 487 493 10.1016/j.jpba.2008.01.036 1:CAS:528:DC%2BD1cXmtlyitrw%3D
    • (2008) J Pharm Biomed Anal , vol.47 , Issue.3 , pp. 487-493
    • Kowalski, P.1
  • 13
    • 33646370513 scopus 로고    scopus 로고
    • Determination of tetracycline, chlortetracycline and oxytetracycline by flow injection with inhibitory chemiluminescence detection using copper(II) as a probe ion
    • DOI 10.1002/bio.893
    • S Han E Liu H Li 2006 Determination of tetracycline, chlortetracycline and oxytetracycline by flow injection with inhibitory chemiluminescence detection using copper(II) as a probe ion Luminescence 21 2 106 111 10.1002/bio.893 1:CAS:528:DC%2BD28Xkslyitrs%3D (Pubitemid 43671989)
    • (2006) Luminescence , vol.21 , Issue.2 , pp. 106-111
    • Han, S.1    Liu, E.2    Li, H.3
  • 14
    • 33846162763 scopus 로고    scopus 로고
    • Human normal T lymphocytes and lymphoid cell lines do express alternative splicing variants of human telomerase reverse transcriptase (hTERT) mRNA
    • DOI 10.1016/j.bbrc.2006.12.149, PII S0006291X06027951
    • M Jalink, et al. 2007 Human normal T lymphocytes and lymphoid cell lines do express alternative splicing variants of human telomerase reverse transcriptase (hTERT) mRNA Biochem Biophys Res Commun 353 4 999 1003 10.1016/j.bbrc.2006.12.149 1:CAS:528:DC%2BD2sXmtVaqug%3D%3D (Pubitemid 46080395)
    • (2007) Biochemical and Biophysical Research Communications , vol.353 , Issue.4 , pp. 999-1003
    • Jalink, M.1    Ge, Z.2    Liu, C.3    Bjorkholm, M.4    Gruber, A.5    Xu, D.6
  • 15
    • 34648814358 scopus 로고    scopus 로고
    • Voltammetry and amperometric detection of tetracyclines at multi-wall carbon nanotube modified electrodes
    • DOI 10.1007/s00216-007-1505-7, Plasma Spectrochemistry
    • D Vega, et al. 2007 Voltammetry and amperometric detection of tetracyclines at multi-wall carbon nanotube modified electrodes Anal Bioanal Chem 389 3 951 958 10.1007/s00216-007-1505-7 1:CAS:528:DC%2BD2sXhtVOmtLbL (Pubitemid 47462465)
    • (2007) Analytical and Bioanalytical Chemistry , vol.389 , Issue.3 , pp. 951-958
    • Vega, D.1    Agui, L.2    Gonzalez-Cortes, A.3    Yanez-Sedeno, P.4    Pingarron, J.M.5
  • 17
    • 0034660177 scopus 로고    scopus 로고
    • A fiber-optic microarray biosensor using aptamers as receptors
    • DOI 10.1006/abio.2000.4595
    • M Lee DR Walt 2000 A fiber-optic microarray biosensor using aptamers as receptors Anal Biochem 282 1 142 146 10.1006/abio.2000.4595 1:CAS:528: DC%2BD3cXktVGrtbg%3D (Pubitemid 30409436)
    • (2000) Analytical Biochemistry , vol.282 , Issue.1 , pp. 142-146
    • Lee, M.1    Walt, D.R.2
  • 18
    • 0038167143 scopus 로고    scopus 로고
    • Aptamer-based biosensor arrays for detection and quantification of biological macromolecules
    • DOI 10.1016/S0003-2697(03)00297-5
    • TG McCauley N Hamaguchi M Stanton 2003 Aptamer-based biosensor arrays for detection and quantification of biological macromolecules Anal Biochem 319 2 244 250 10.1016/S0003-2697(03)00297-5 1:CAS:528:DC%2BD3sXlsVSnu7g%3D (Pubitemid 36842733)
    • (2003) Analytical Biochemistry , vol.319 , Issue.2 , pp. 244-250
    • McCauley, T.G.1    Hamaguchi, N.2    Stanton, M.3
  • 19
    • 39749179700 scopus 로고    scopus 로고
    • Aptamer-based optical probes with separated molecular recognition and signal transduction modules
    • DOI 10.1021/ja076787b
    • N Li CM Ho 2008 Aptamer-based optical probes with separated molecular recognition and signal transduction modules J Am Chem Soc 130 8 2380 2381 10.1021/ja076787b 1:CAS:528:DC%2BD1cXhsVKlsLY%3D (Pubitemid 351304721)
    • (2008) Journal of the American Chemical Society , vol.130 , Issue.8 , pp. 2380-2381
    • Li, N.1    Ho, C.-M.2
  • 20
    • 0036712790 scopus 로고    scopus 로고
    • An aptamer-based quartz crystal protein biosensor
    • DOI 10.1021/ac011294p
    • M Liss, et al. 2002 An aptamer-based quartz crystal protein biosensor Anal Chem 74 17 4488 4495 10.1021/ac011294p 1:CAS:528:DC%2BD38XlsFarsbk%3D (Pubitemid 35006438)
    • (2002) Analytical Chemistry , vol.74 , Issue.17 , pp. 4488-4495
    • Liss, M.1    Petersen, B.2    Wolf, H.3    Prohaska, E.4
  • 21
    • 8844269129 scopus 로고    scopus 로고
    • Development of biosensors with aptamers as bio-recognition element: The case of HIV-1 Tat protein
    • DOI 10.1016/j.bios.2004.03.037, PII S095656630400274X, Synthetic Receptors
    • M Minunni, et al. 2004 Development of biosensors with aptamers as bio-recognition element: the case of HIV-1 Tat protein Biosens Bioelectron 20 6 1149 1156 10.1016/j.bios.2004.03.037 1:CAS:528:DC%2BD2cXhtVSntLvK (Pubitemid 39535573)
    • (2004) Biosensors and Bioelectronics , vol.20 , Issue.6 , pp. 1149-1156
    • Minunni, M.1    Tombelli, S.2    Gullotto, A.3    Luzi, E.4    Mascini, M.5
  • 22
    • 42349091244 scopus 로고    scopus 로고
    • SDNA aptamer-based surface plasmon resonance biosensor for the detection of retinol binding protein 4 for the early diagnosis of type 2 diabetes
    • DOI 10.1021/ac800050a
    • SJ Lee, et al. 2008 ssDNA aptamer-based surface plasmon resonance biosensor for the detection of retinol binding protein 4 for the early diagnosis of type 2 diabetes Anal Chem 80 8 2867 2873 10.1021/ac800050a 1:CAS:528:DC%2BD1cXivV2gt7s%3D (Pubitemid 351556450)
    • (2008) Analytical Chemistry , vol.80 , Issue.8 , pp. 2867-2873
    • Su, J.L.1    Youn, B.-S.2    Ji, W.P.3    Niazi, J.H.4    Yeon, S.K.5    Man, B.G.6
  • 23
    • 39449134516 scopus 로고    scopus 로고
    • Gold nanoparticle-based colorimetric assay for the direct detection of cancerous cells
    • DOI 10.1021/ac702037y
    • CD Medley, et al. 2008 Gold nanoparticle-based colorimetric assay for the direct detection of cancerous cells Anal Chem 80 4 1067 1072 10.1021/ac702037y 1:CAS:528:DC%2BD1cXmtlersg%3D%3D (Pubitemid 351272339)
    • (2008) Analytical Chemistry , vol.80 , Issue.4 , pp. 1067-1072
    • Medley, C.D.1    Smith, J.E.2    Tang, Z.3    Wu, Y.4    Bamrungsap, S.5    Tan, W.6
  • 24
    • 29344462970 scopus 로고    scopus 로고
    • Fast colorimetric sensing of adenosine and cocaine based on a general sensor design involving aptamers and nanoparticles
    • DOI 10.1002/anie.200502589
    • JW Liu Y Lu 2006 Fast colorimetric sensing of adenosine and cocaine based on a general sensor design involving aptamers and nanoparticles Angew Chem 45 1 90 94 10.1002/anie.200502589 1:CAS:528:DC%2BD28XhslKgtQ%3D%3D (Pubitemid 43003993)
    • (2006) Angewandte Chemie - International Edition , vol.45 , Issue.1 , pp. 90-94
    • Liu, J.1    Lu, Y.2
  • 25
    • 0037151612 scopus 로고    scopus 로고
    • Aptamer-based colorimetric probe for cocaine
    • DOI 10.1021/ja0259483
    • MN Stojanovic DW Landry 2002 Aptamer-based colorimetric probe for cocaine J Am Chem Soc 124 33 9678 9679 10.1021/ja0259483 1:CAS:528:DC%2BD38XlsFygtbo%3D (Pubitemid 34906902)
    • (2002) Journal of the American Chemical Society , vol.124 , Issue.33 , pp. 9678-9679
    • Stojanovic, M.N.1    Landry, D.W.2
  • 26
    • 34548331295 scopus 로고    scopus 로고
    • Electronic aptamer-based sensors
    • DOI 10.1002/anie.200604524
    • I Willner M Zayats 2007 Electronic aptamer-based sensors Angew Chem 46 34 6408 6418 10.1002/anie.200604524 1:CAS:528:DC%2BD2sXhtVOhsL3N (Pubitemid 47340164)
    • (2007) Angewandte Chemie - International Edition , vol.46 , Issue.34 , pp. 6408-6418
    • Willner, I.1    Zayats, M.2
  • 27
    • 70449112341 scopus 로고    scopus 로고
    • Electrochemical aptamer-based Biosensors
    • YS Kim SJ Lee MB Gu 2008 Electrochemical aptamer-based Biosensors Biochip J 2 3 175 182
    • (2008) Biochip J , vol.2 , Issue.3 , pp. 175-182
    • Kim, Y.S.1    Lee, S.J.2    Gu, M.B.3
  • 28
    • 14644409719 scopus 로고    scopus 로고
    • Novel electrochemical sensor system for protein using the aptamers in sandwich manner
    • DOI 10.1016/j.bios.2004.09.002, PII S0956566304004105
    • K Ikebukuro C Kiyohara K Sode 2005 Novel electrochemical sensor system for protein using the aptamers in sandwich manner Biosens Bioelectron 20 10 2168 2172 10.1016/j.bios.2004.09.002 1:CAS:528:DC%2BD2MXhsleitb8%3D (Pubitemid 40312118)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.10 SPEC. ISS. , pp. 2168-2172
    • Ikebukuro, K.1    Kiyohara, C.2    Sode, K.3
  • 29
    • 42649137553 scopus 로고    scopus 로고
    • Different approaches for the detection of thrombin by an electrochemical aptamer-based assay coupled to magnetic beads
    • 10.1016/j.bios.2008.01.020 1:CAS:528:DC%2BD1cXlslKgtrY%3D
    • S Centi, et al. 2008 Different approaches for the detection of thrombin by an electrochemical aptamer-based assay coupled to magnetic beads Biosens Bioelectron 23 11 1602 1609 10.1016/j.bios.2008.01.020 1:CAS:528: DC%2BD1cXlslKgtrY%3D
    • (2008) Biosens Bioelectron , vol.23 , Issue.11 , pp. 1602-1609
    • Centi, S.1
  • 30
    • 33847196810 scopus 로고    scopus 로고
    • Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads
    • DOI 10.1021/ac061879p
    • S Centi, et al. 2007 Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads Anal Chem 79 4 1466 1473 10.1021/ac061879p 1:CAS:528:DC%2BD2sXltVCgsQ%3D%3D (Pubitemid 46309637)
    • (2007) Analytical Chemistry , vol.79 , Issue.4 , pp. 1466-1473
    • Centi, S.1    Tombelli, S.2    Minunni, M.3    Mascini, M.4
  • 31
    • 43849087030 scopus 로고    scopus 로고
    • Electrochemical immunosensor with aptamer-based enzymatic amplification
    • 10.1016/j.ab.2008.03.047 1:CAS:528:DC%2BD1cXmsVegtLY%3D
    • K Feng, et al. 2008 Electrochemical immunosensor with aptamer-based enzymatic amplification Anal Biochem 378 1 38 42 10.1016/j.ab.2008.03.047 1:CAS:528:DC%2BD1cXmsVegtLY%3D
    • (2008) Anal Biochem , vol.378 , Issue.1 , pp. 38-42
    • Feng, K.1
  • 32
    • 35848961028 scopus 로고    scopus 로고
    • Ultrasensitive electrochemical detection of proteins by amplification of aptamer-nanoparticle bio bar codes
    • DOI 10.1021/ac070772e
    • P He, et al. 2007 Ultrasensitive electrochemical detection of proteins by amplification of aptamer-nanoparticle bio bar codes Anal Chem 79 21 8024 8029 10.1021/ac070772e 1:CAS:528:DC%2BD2sXhtVKmsbzI (Pubitemid 350059997)
    • (2007) Analytical Chemistry , vol.79 , Issue.21 , pp. 8024-8029
    • He, P.1    Shen, L.2    Cao, Y.3    Li, D.4
  • 33
    • 38749099480 scopus 로고    scopus 로고
    • Amplified electrochemical aptasensor taking AuNPs based sandwich sensing platform as a model
    • DOI 10.1016/j.bios.2007.09.019, PII S0956566307004137
    • B Li, et al. 2008 Amplified electrochemical aptasensor taking AuNPs based sandwich sensing platform as a model Biosens Bioelectron 23 7 965 970 10.1016/j.bios.2007.09.019 1:CAS:528:DC%2BD1cXhsFymtrs%3D (Pubitemid 351178701)
    • (2008) Biosensors and Bioelectronics , vol.23 , Issue.7 , pp. 965-970
    • Li, B.1    Wang, Y.2    Wei, H.3    Dong, S.4
  • 35
    • 24644478623 scopus 로고    scopus 로고
    • Label-free electronic detection of thrombin in blood serum by using an aptamer-based sensor
    • DOI 10.1002/anie.200500989
    • Y Xiao, et al. 2005 Label-free electronic detection of thrombin in blood serum by using an aptamer-based sensor Angew Chem 44 34 5456 5459 10.1002/anie.200500989 1:CAS:528:DC%2BD2MXpvF2ksLg%3D (Pubitemid 41273294)
    • (2005) Angewandte Chemie - International Edition , vol.44 , Issue.34 , pp. 5456-5459
    • Xiao, Y.1    Lubin, A.A.2    Heeger, A.J.3    Plaxco, K.W.4
  • 36
    • 29844453471 scopus 로고    scopus 로고
    • A reagentless signal-on architecture for electronic, aptamer-based sensors via target-induced strand displacement
    • DOI 10.1021/ja056555h
    • Y Xiao, et al. 2005 A reagentless signal-on architecture for electronic, aptamer-based sensors via target-induced strand displacement J Am Chem Soc 127 51 17990 17991 10.1021/ja056555h 1:CAS:528:DC%2BD2MXht1Gru7zF (Pubitemid 43038446)
    • (2005) Journal of the American Chemical Society , vol.127 , Issue.51 , pp. 17990-17991
    • Xiao, Y.1    Piorek, B.D.2    Plaxco, K.W.3    Heegert, A.J.4
  • 37
    • 33644942097 scopus 로고    scopus 로고
    • An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological fluids
    • 10.1021/ja056957p 1:CAS:528:DC%2BD28XhsFarsb0%3D
    • BR Baker, et al. 2006 An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological fluids J Am Chem Soc 128 10 3138 3139 10.1021/ja056957p 1:CAS:528:DC%2BD28XhsFarsb0%3D
    • (2006) J Am Chem Soc , vol.128 , Issue.10 , pp. 3138-3139
    • Baker, B.R.1
  • 40
    • 34247176267 scopus 로고    scopus 로고
    • Reusable electrochemical sensing platform for highly sensitive detection of small molecules based on structure-switching signaling aptamers
    • DOI 10.1021/ac0622936
    • ZS Wu, et al. 2007 Reusable electrochemical sensing platform for highly sensitive detection of small molecules based on structure-switching signaling aptamers Anal Chem 79 7 2933 2939 10.1021/ac0622936 1:CAS:528: DC%2BD2sXisVajsbc%3D (Pubitemid 46595648)
    • (2007) Analytical Chemistry , vol.79 , Issue.7 , pp. 2933-2939
    • Wu, Z.-S.1    Guo, M.-M.2    Zhang, S.-B.3    Chen, C.-R.4    Jiang, J.-H.5    Shen, G.-L.6    Yu, R.-Q.7
  • 41
    • 40849120473 scopus 로고    scopus 로고
    • Label-free electrochemical detection of nanomolar adenosine based on target-induced aptamer displacement
    • 10.1016/j.elecom.2008.01.024 1:CAS:528:DC%2BD1cXjs1ansb8%3D
    • K Feng C Sun Y Kang J Chen J Jiang G Shen R Yu 2008 Label-free electrochemical detection of nanomolar adenosine based on target-induced aptamer displacement Electrochem Commun 10 531 535 10.1016/j.elecom.2008.01.024 1:CAS:528:DC%2BD1cXjs1ansb8%3D
    • (2008) Electrochem Commun , vol.10 , pp. 531-535
    • Feng, K.1    Sun, C.2    Kang, Y.3    Chen, J.4    Jiang, J.5    Shen, G.6    Yu, R.7
  • 42
    • 48449084598 scopus 로고    scopus 로고
    • Single-stranded DNA aptamers specific for antibiotics tetracyclines
    • 10.1016/j.bmc.2008.06.033 1:CAS:528:DC%2BD1cXps12jtL4%3D
    • JH Niazi SJ Lee MB Gu 2008 Single-stranded DNA aptamers specific for antibiotics tetracyclines Bioorg Med Chem 16 15 7245 7253 10.1016/j.bmc.2008.06. 033 1:CAS:528:DC%2BD1cXps12jtL4%3D
    • (2008) Bioorg Med Chem , vol.16 , Issue.15 , pp. 7245-7253
    • Niazi, J.H.1    Lee, S.J.2    Gu, M.B.3
  • 43
    • 0042121256 scopus 로고    scopus 로고
    • Mfold web server for nucleic acid folding and hybridization prediction
    • DOI 10.1093/nar/gkg595
    • M Zuker 2003 Mfold web server for nucleic acid folding and hybridization prediction Nucleic Acids Res 31 13 3406 3415 10.1093/nar/gkg595 1:CAS:528:DC%2BD3sXltVWisr8%3D (Pubitemid 37442169)
    • (2003) Nucleic Acids Research , vol.31 , Issue.13 , pp. 3406-3415
    • Zuker, M.1
  • 44
    • 0442329215 scopus 로고    scopus 로고
    • Electrochemical detection of nonlabeled oligonucleotide DNA using biotin-modified DNA(ss) on a streptavidin-modified gold electrode
    • 1:CAS:528:DC%2BD2cXis1aktro%3D
    • JW Park, et al. 2004 Electrochemical detection of nonlabeled oligonucleotide DNA using biotin-modified DNA(ss) on a streptavidin-modified gold electrode J Biosci Bioeng 97 1 29 32 1:CAS:528:DC%2BD2cXis1aktro%3D
    • (2004) J Biosci Bioeng , vol.97 , Issue.1 , pp. 29-32
    • Park, J.W.1
  • 45
    • 35648975233 scopus 로고    scopus 로고
    • Thermodynamics of tetracycline adsorption on silica
    • DOI 10.1007/s10311-007-0106-1
    • I Turku T Sainio E Paatero 2007 Thermodynamics of tetracycline adsorption on silica Environ Chem Lett 5 225 228 10.1007/s10311-007-0106-1 1:CAS:528:DC%2BD2sXhsVSnsbjE (Pubitemid 350020665)
    • (2007) Environmental Chemistry Letters , vol.5 , Issue.4 , pp. 225-228
    • Turku, I.1    Sainio, T.2    Paatero, E.3
  • 46
    • 33947579554 scopus 로고    scopus 로고
    • Electrochemical detection of 17β-estradiol using DNA aptamer immobilized gold electrode chip
    • DOI 10.1016/j.bios.2006.10.004, PII S0956566306004854
    • YS Kim, et al. 2007 Electrochemical detection of 17beta-estradiol using DNA aptamer immobilized gold electrode chip Biosens Bioelectron 22 11 2525 2531 10.1016/j.bios.2006.10.004 1:CAS:528:DC%2BD2sXjslGmt74%3D (Pubitemid 46484241)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.11 , pp. 2525-2531
    • Kim, Y.S.1    Jung, H.S.2    Matsuura, T.3    Lee, H.Y.4    Kawai, T.5    Gu, M.B.6
  • 47
    • 58549100235 scopus 로고    scopus 로고
    • Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip
    • 10.1016/j.aca.2008.12.025 1:CAS:528:DC%2BD1MXhsV2is7Y%3D
    • YS Kim JH Niazi MB Gu 2009 Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip Anal Chim Acta 634 2 250 254 10.1016/j.aca.2008.12.025 1:CAS:528:DC%2BD1MXhsV2is7Y%3D
    • (2009) Anal Chim Acta , vol.634 , Issue.2 , pp. 250-254
    • Kim, Y.S.1    Niazi, J.H.2    Gu, M.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.