메뉴 건너뛰기




Volumn 7, Issue 3, 2010, Pages 331-332

Loss of pace capture on the ablation line: The quest for a more reliable endpoint for pulmonary vein isolation

Author keywords

[No Author keywords available]

Indexed keywords

CARDIOVASCULAR PROCEDURES; CATHETER ABLATION; CLINICAL ASSESSMENT; EDITORIAL; ELECTROGRAPHY; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEART CONDUCTION; HEART ELECTROPHYSIOLOGY; HEART PACING; HUMAN; PRIORITY JOURNAL; PULMONARY VEIN; PULMONARY VEIN ISOLATION; SINUS RHYTHM; THROMBOEMBOLISM;

EID: 76849090281     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2009.11.028     Document Type: Editorial
Times cited : (4)

References (11)
  • 1
    • 34249814933 scopus 로고    scopus 로고
    • HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation
    • Calkins H., Brugada J., Packer D.L., et al. HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation. Heart Rhythm 4 (2007) 816-861
    • (2007) Heart Rhythm , vol.4 , pp. 816-861
    • Calkins, H.1    Brugada, J.2    Packer, D.L.3
  • 2
    • 33947214007 scopus 로고    scopus 로고
    • Incidence and time course of early recovery of pulmonary vein conduction after catheter ablation of atrial fibrillation
    • Cheema A., Dong J., Dalal D., et al. Incidence and time course of early recovery of pulmonary vein conduction after catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 18: (2007) 387-391
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 387-391
    • Cheema, A.1    Dong, J.2    Dalal, D.3
  • 3
    • 19944430314 scopus 로고    scopus 로고
    • Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique
    • Ouyang F., Antz M., Ernst S., et al. Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique. Circulation 111 (2005) 127-135
    • (2005) Circulation , vol.111 , pp. 127-135
    • Ouyang, F.1    Antz, M.2    Ernst, S.3
  • 4
    • 33747823241 scopus 로고    scopus 로고
    • Clinical predictors and outcomes associated with acute return of pulmonary vein conduction during pulmonary vein isolation for treatment of atrial fibrillation
    • Sauer W.H., McKernan M.L., Lin D., et al. Clinical predictors and outcomes associated with acute return of pulmonary vein conduction during pulmonary vein isolation for treatment of atrial fibrillation. Heart Rhythm 3 (2006) 1024-1028
    • (2006) Heart Rhythm , vol.3 , pp. 1024-1028
    • Sauer, W.H.1    McKernan, M.L.2    Lin, D.3
  • 5
    • 76849105431 scopus 로고    scopus 로고
    • Loss of pace-capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation
    • Steven D., Reddy V.Y., Inada K., et al. Loss of pace-capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation. Heart Rhythm 7 (2010) 323-330
    • (2010) Heart Rhythm , vol.7 , pp. 323-330
    • Steven, D.1    Reddy, V.Y.2    Inada, K.3
  • 6
    • 0142042325 scopus 로고    scopus 로고
    • Assessment of radiofrequency ablation effect from unipolar pacing threshold
    • Delacretaz E., Soejima K., Brunckhorst C.B., et al. Assessment of radiofrequency ablation effect from unipolar pacing threshold. Pacing Clin Electrophysiol 26 (2003) 1993-1996
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 1993-1996
    • Delacretaz, E.1    Soejima, K.2    Brunckhorst, C.B.3
  • 7
    • 3242801305 scopus 로고    scopus 로고
    • Ablation lesion size correlates with pacing threshold: a physiological basis for use of pacing to assess ablation lesions
    • Sapp J.L., Soejima K., Cooper J.M., et al. Ablation lesion size correlates with pacing threshold: a physiological basis for use of pacing to assess ablation lesions. Pacing Clin Electrophysiol 27 (2004) 933-937
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 933-937
    • Sapp, J.L.1    Soejima, K.2    Cooper, J.M.3
  • 8
    • 0037167690 scopus 로고    scopus 로고
    • Electrically unexcitable scar mapping based on pacing threshold for identification of the reentry circuit isthmus: feasibility for guiding ventricular tachycardia ablation
    • Soejima K., Stevenson W.G., Maisel W.H., et al. Electrically unexcitable scar mapping based on pacing threshold for identification of the reentry circuit isthmus: feasibility for guiding ventricular tachycardia ablation. Circulation 106 (2002) 1678-1683
    • (2002) Circulation , vol.106 , pp. 1678-1683
    • Soejima, K.1    Stevenson, W.G.2    Maisel, W.H.3
  • 9
    • 74449092235 scopus 로고    scopus 로고
    • Circumferential pulmonary vein isolation and linear left atrial ablation as single catheter technique to achieve bidirectional conduction block: the "pace-and-ablate" approach
    • Eitel C., Hindricks G., Sommer P., et al. Circumferential pulmonary vein isolation and linear left atrial ablation as single catheter technique to achieve bidirectional conduction block: the "pace-and-ablate" approach. Heart Rhythm 7 (2010) 157-164
    • (2010) Heart Rhythm , vol.7 , pp. 157-164
    • Eitel, C.1    Hindricks, G.2    Sommer, P.3
  • 10
    • 33748756679 scopus 로고    scopus 로고
    • Implantation of bilateral carotid artery filters to allow safe removal of left atrial thrombus during ablation of atrial fibrillation
    • Martelo S., D'Avila A., Ferreira F., and Saad E.B. Implantation of bilateral carotid artery filters to allow safe removal of left atrial thrombus during ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17 (2006) 1140-1141
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 1140-1141
    • Martelo, S.1    D'Avila, A.2    Ferreira, F.3    Saad, E.B.4
  • 11
    • 33845777224 scopus 로고    scopus 로고
    • Entrapment of circular mapping catheter in the mitral valve
    • Kesek M., Englund A., Jensen S.M., and Jensen-Urstad M. Entrapment of circular mapping catheter in the mitral valve. Heart Rhythm 4 (2007) 17-19
    • (2007) Heart Rhythm , vol.4 , pp. 17-19
    • Kesek, M.1    Englund, A.2    Jensen, S.M.3    Jensen-Urstad, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.