메뉴 건너뛰기




Volumn 4, Issue 1, 2007, Pages 17-19

Entrapment of circular mapping catheter in the mitral valve

Author keywords

Ablation; Atrial fibrillation; Catheter entrapment; Complication; Mitral valve

Indexed keywords

ADULT; AORTA SURGERY; ARTICLE; CASE REPORT; CATHETER ABLATION; CONFIDENCE INTERVAL; FLUOROSCOPY; HEART ATRIUM FIBRILLATION; HEART ELECTROPHYSIOLOGY; HUMAN; INCIDENCE; MALE; MITRAL VALVE REGURGITATION; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; PULMONARY VEIN; SURGICAL TECHNIQUE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 33845777224     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2006.09.016     Document Type: Article
Times cited : (55)

References (6)
  • 1
    • 0031968592 scopus 로고    scopus 로고
    • Catheter entrapment in the mitral valve apparatus requiring surgical removal: an unusual complication of radiofrequency ablation
    • Mandawat M.K., Turitto G., and El-Sherif N. Catheter entrapment in the mitral valve apparatus requiring surgical removal: an unusual complication of radiofrequency ablation. Pacing Clin Electrophysiol 21 (1998) 772-773
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 772-773
    • Mandawat, M.K.1    Turitto, G.2    El-Sherif, N.3
  • 2
    • 0028124558 scopus 로고
    • Catheter entrapment in the mitral valve apparatus during radiofrequency ablation
    • Conti J.B., Geiser E., and Curtis A.B. Catheter entrapment in the mitral valve apparatus during radiofrequency ablation. Pacing Clin Electrophysiol 17 (1994) 1681-1685
    • (1994) Pacing Clin Electrophysiol , vol.17 , pp. 1681-1685
    • Conti, J.B.1    Geiser, E.2    Curtis, A.B.3
  • 3
    • 7744245476 scopus 로고    scopus 로고
    • Successful release of entrapped circumferential mapping catheters in patients undergoing pulmonary vein isolation for atrial fibrillation
    • Mansour M., Mela T., Ruskin J., and Keane D. Successful release of entrapped circumferential mapping catheters in patients undergoing pulmonary vein isolation for atrial fibrillation. Heart Rhythm 1 (2004) 558-561
    • (2004) Heart Rhythm , vol.1 , pp. 558-561
    • Mansour, M.1    Mela, T.2    Ruskin, J.3    Keane, D.4
  • 4
    • 0042700310 scopus 로고    scopus 로고
    • Fracture of a circular mapping catheter after entrapment in the mitral valve apparatus during segmental pulmonary vein isolation
    • Tavernier R., Duytschaever M., and Taeymans Y. Fracture of a circular mapping catheter after entrapment in the mitral valve apparatus during segmental pulmonary vein isolation. Pacing Clin Electrophysiol 26 (2003) 1774-1775
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 1774-1775
    • Tavernier, R.1    Duytschaever, M.2    Taeymans, Y.3
  • 5
    • 0036667624 scopus 로고    scopus 로고
    • Circular mapping catheter entrapment in the mitral valve apparatus: a previously unrecognized complication of focal atrial fibrillation ablation
    • Wu R.C., Brinker J.A., Yuh D.D., Berger R.D., and Calkins H.G. Circular mapping catheter entrapment in the mitral valve apparatus: a previously unrecognized complication of focal atrial fibrillation ablation. J Cardiovasc Electrophysiol 13 (2002) 819-821
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 819-821
    • Wu, R.C.1    Brinker, J.A.2    Yuh, D.D.3    Berger, R.D.4    Calkins, H.G.5