메뉴 건너뛰기




Volumn 149, Issue 3, 2010, Pages

Wavefront Analysis, Contrast Sensitivity, and Depth of Focus After Cataract Surgery With Aspherical Intraocular Lens Implantation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CATARACT; CATARACT EXTRACTION; CLINICAL ARTICLE; CLINICAL TRIAL; CONTRAST SENSITIVITY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DOUBLE BLIND PROCEDURE; FEMALE; HUMAN; LENS IMPLANT; MALE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; RETINOSCOPY; VISUAL ACUITY;

EID: 76749100673     PISSN: 00029394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajo.2009.09.019     Document Type: Article
Times cited : (35)

References (37)
  • 1
    • 57649218728 scopus 로고    scopus 로고
    • Analysis of the possible benefits of aspheric intraocular lenses: review of the literature
    • Montés-Micó R., Ferrer-Blasco T., and Cerviño A. Analysis of the possible benefits of aspheric intraocular lenses: review of the literature. J Cataract Refract Surg 35 (2009) 172-181
    • (2009) J Cataract Refract Surg , vol.35 , pp. 172-181
    • Montés-Micó, R.1    Ferrer-Blasco, T.2    Cerviño, A.3
  • 2
    • 58149267629 scopus 로고    scopus 로고
    • Recent development in aspheric intraocular lenses
    • Dick H.B. Recent development in aspheric intraocular lenses. Curr Opin Ophthalmol 20 (2009) 25-32
    • (2009) Curr Opin Ophthalmol , vol.20 , pp. 25-32
    • Dick, H.B.1
  • 4
    • 0036859728 scopus 로고    scopus 로고
    • Prospective randomized trial of an anterior surface modified prolate intraocular lens
    • Packer M., Fine H., Hoffman R.S., and Piers P.A. Prospective randomized trial of an anterior surface modified prolate intraocular lens. J Refract Surg 18 (2002) 692-696
    • (2002) J Refract Surg , vol.18 , pp. 692-696
    • Packer, M.1    Fine, H.2    Hoffman, R.S.3    Piers, P.A.4
  • 5
    • 0037387972 scopus 로고    scopus 로고
    • Impact of a modified optic design on visual function: clinical comparative study
    • Mester U., Dillinger P., and Anterist N. Impact of a modified optic design on visual function: clinical comparative study. J Cataract Refract Surg 29 (2003) 652-660
    • (2003) J Cataract Refract Surg , vol.29 , pp. 652-660
    • Mester, U.1    Dillinger, P.2    Anterist, N.3
  • 6
    • 0141643152 scopus 로고    scopus 로고
    • Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses; prospective evaluation
    • Kershner R.M. Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses; prospective evaluation. J Cataract Refract Surg 29 (2003) 1684-1694
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1684-1694
    • Kershner, R.M.1
  • 7
    • 19344374372 scopus 로고    scopus 로고
    • Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: a multicenter randomized study
    • Bellucci R., Scialdone A., Buratto L., et al. Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: a multicenter randomized study. J Cataract Refract Surg 31 (2005) 712-717
    • (2005) J Cataract Refract Surg , vol.31 , pp. 712-717
    • Bellucci, R.1    Scialdone, A.2    Buratto, L.3
  • 8
    • 34548713585 scopus 로고    scopus 로고
    • Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes
    • Caporossi A., Martone G., Casprini F., and Rapisarda L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J Refract Surg 23 (2007) 639-648
    • (2007) J Refract Surg , vol.23 , pp. 639-648
    • Caporossi, A.1    Martone, G.2    Casprini, F.3    Rapisarda, L.4
  • 9
    • 35348960381 scopus 로고    scopus 로고
    • Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation; clinical comparative study
    • Tzelikis P.F., Akaishi L., Trindade F.C., and Boteon J.E. Ocular aberrations and contrast sensitivity after cataract surgery with AcrySof IQ intraocular lens implantation; clinical comparative study. J Cataract Refract Surg 33 (2007) 1918-1924
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1918-1924
    • Tzelikis, P.F.1    Akaishi, L.2    Trindade, F.C.3    Boteon, J.E.4
  • 10
    • 43049138747 scopus 로고    scopus 로고
    • Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study
    • Tzelikis P.F., Akaishi L., Trindade F.C., and Boteon J.E. Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study. Am J Ophthalmol 145 (2008) 827-833
    • (2008) Am J Ophthalmol , vol.145 , pp. 827-833
    • Tzelikis, P.F.1    Akaishi, L.2    Trindade, F.C.3    Boteon, J.E.4
  • 11
    • 33947595775 scopus 로고    scopus 로고
    • Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lens: prospective randomized masked clinical trial
    • Pandita D., Raj S.M., Vasavada V.A., Vasavada V.A., Kazi N.S., and Vasavada A.R. Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lens: prospective randomized masked clinical trial. J Cataract Refract Surg 33 (2007) 603-610
    • (2007) J Cataract Refract Surg , vol.33 , pp. 603-610
    • Pandita, D.1    Raj, S.M.2    Vasavada, V.A.3    Vasavada, V.A.4    Kazi, N.S.5    Vasavada, A.R.6
  • 12
    • 45249108838 scopus 로고    scopus 로고
    • Contrast sensitivity and higher order aberrations in eyes implanted with Acrysof IQ SN60WF and AcrySof SN60AT intraocular lenses
    • Awwad S.T., Warmerdam D., Bowman R.W., Dwarakanathan S., Cavanagh H.D., and McCulley J.P. Contrast sensitivity and higher order aberrations in eyes implanted with Acrysof IQ SN60WF and AcrySof SN60AT intraocular lenses. J Refract Surg 24 (2008) 619-625
    • (2008) J Refract Surg , vol.24 , pp. 619-625
    • Awwad, S.T.1    Warmerdam, D.2    Bowman, R.W.3    Dwarakanathan, S.4    Cavanagh, H.D.5    McCulley, J.P.6
  • 13
    • 54149099936 scopus 로고    scopus 로고
    • Comparison of the AcrySof IQ aspheric blue light filter and the Acrysof SA60AT intraocular lenses
    • Mester U., and Kaymak H. Comparison of the AcrySof IQ aspheric blue light filter and the Acrysof SA60AT intraocular lenses. J Refract Surg 24 (2008) 817-825
    • (2008) J Refract Surg , vol.24 , pp. 817-825
    • Mester, U.1    Kaymak, H.2
  • 14
    • 3242772864 scopus 로고    scopus 로고
    • Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses
    • Bellucci R., Morselli S., and Piers P. Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses. J Refract Surg 20 (2004) 297-306
    • (2004) J Refract Surg , vol.20 , pp. 297-306
    • Bellucci, R.1    Morselli, S.2    Piers, P.3
  • 15
    • 3242699462 scopus 로고    scopus 로고
    • Wavefront-customized intraocular lenses
    • Altmann G.E. Wavefront-customized intraocular lenses. Curr Opin Ophthalmol 15 (2004) 358-364
    • (2004) Curr Opin Ophthalmol , vol.15 , pp. 358-364
    • Altmann, G.E.1
  • 18
    • 1642416661 scopus 로고    scopus 로고
    • Glenn Fry award lecture 2002: wavefront sensing ideal corrections and visual performance
    • Applegate R.A. Glenn Fry award lecture 2002: wavefront sensing ideal corrections and visual performance. Optom Vis Sci 81 (2004) 167-177
    • (2004) Optom Vis Sci , vol.81 , pp. 167-177
    • Applegate, R.A.1
  • 21
    • 32244431972 scopus 로고    scopus 로고
    • Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro
    • Kawamorita T., and Uozato H. Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro. J Cataract Refract Surg 31 (2005) 2379-2385
    • (2005) J Cataract Refract Surg , vol.31 , pp. 2379-2385
    • Kawamorita, T.1    Uozato, H.2
  • 22
    • 34548119818 scopus 로고    scopus 로고
    • Visual and optical performance of the Akreos Adapt Advanced Optics and Tecnis Z9000 intraocular lenses: Swedish multicenter study
    • Johansson B., Sundelin S., Wikberg-Matsson A., Unsbo P., and Behndig A. Visual and optical performance of the Akreos Adapt Advanced Optics and Tecnis Z9000 intraocular lenses: Swedish multicenter study. J Cataract Refract Surg 33 (2007) 1565-1572
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1565-1572
    • Johansson, B.1    Sundelin, S.2    Wikberg-Matsson, A.3    Unsbo, P.4    Behndig, A.5
  • 23
    • 58649087193 scopus 로고    scopus 로고
    • Visual performance and contrast sensitivity after phacoemulsification with implantation of aspheric foldable intraocular lenses
    • Nabh R., Ram J., Pandav S.S., and Gupta A. Visual performance and contrast sensitivity after phacoemulsification with implantation of aspheric foldable intraocular lenses. J Cataract Refract Surg 35 (2009) 347-353
    • (2009) J Cataract Refract Surg , vol.35 , pp. 347-353
    • Nabh, R.1    Ram, J.2    Pandav, S.S.3    Gupta, A.4
  • 24
    • 57149118077 scopus 로고    scopus 로고
    • Intraindividual comparative study of corneal and ocular wavefront aberrations after biaxial microincision versus coaxial small-incision cataract surgery
    • Denoyer A., Denoyer L., Marotte D., Georget M., and Pisella P.J. Intraindividual comparative study of corneal and ocular wavefront aberrations after biaxial microincision versus coaxial small-incision cataract surgery. Br J Ophthalmol 92 (2008) 1679-1684
    • (2008) Br J Ophthalmol , vol.92 , pp. 1679-1684
    • Denoyer, A.1    Denoyer, L.2    Marotte, D.3    Georget, M.4    Pisella, P.J.5
  • 25
    • 55649116374 scopus 로고    scopus 로고
    • Spherical aberration, visual performance and pseudoaccommodation of eyes implanted with different aspheric intraocular lens
    • Shentu X., Tang X., and Yao K. Spherical aberration, visual performance and pseudoaccommodation of eyes implanted with different aspheric intraocular lens. Clin Experiment Ophthalmol 36 (2008) 620-624
    • (2008) Clin Experiment Ophthalmol , vol.36 , pp. 620-624
    • Shentu, X.1    Tang, X.2    Yao, K.3
  • 26
    • 0033927053 scopus 로고    scopus 로고
    • Dysphotopsia in phakic and pseudophakic patients: Incidence and relation to intraocular lens type
    • Tester R., Pace N.L., Samore M., and Olson R.J. Dysphotopsia in phakic and pseudophakic patients: Incidence and relation to intraocular lens type. J Cataract Refract Surg 26 (2000) 810-816
    • (2000) J Cataract Refract Surg , vol.26 , pp. 810-816
    • Tester, R.1    Pace, N.L.2    Samore, M.3    Olson, R.J.4
  • 27
    • 33644669989 scopus 로고    scopus 로고
    • Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter
    • Kasper T., Buhren J., and Kohnen T. Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter. J Cataract Refract Surg 32 (2006) 78-84
    • (2006) J Cataract Refract Surg , vol.32 , pp. 78-84
    • Kasper, T.1    Buhren, J.2    Kohnen, T.3
  • 28
    • 18844456295 scopus 로고    scopus 로고
    • Optical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lenses
    • Marcos S., Barbero S., and Jiménez-Alfaro I. Optical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lenses. J Refract Surg 21 (2005) 223-235
    • (2005) J Refract Surg , vol.21 , pp. 223-235
    • Marcos, S.1    Barbero, S.2    Jiménez-Alfaro, I.3
  • 29
    • 33750084170 scopus 로고    scopus 로고
    • Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study
    • Rocha K.M., Soriano E.S., Chalita M.R., et al. Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study. Am J Ophthalmol 142 (2006) 750-756
    • (2006) Am J Ophthalmol , vol.142 , pp. 750-756
    • Rocha, K.M.1    Soriano, E.S.2    Chalita, M.R.3
  • 30
    • 25144506466 scopus 로고    scopus 로고
    • Limitations of correcting spherical aberration with aspheric intraocular lenses
    • Dietze H.H., and Cox M.J. Limitations of correcting spherical aberration with aspheric intraocular lenses. J Refract Surg 21 (2005) S541-S546
    • (2005) J Refract Surg , vol.21
    • Dietze, H.H.1    Cox, M.J.2
  • 31
    • 0026346157 scopus 로고
    • Intraocular lens explantation and exchange: a review of lens styles, clinical indications, clinical results and visual outcome
    • Mamalis N., Crandall A.S., Pulsipher M.W., Follett S., and Monson M.C. Intraocular lens explantation and exchange: a review of lens styles, clinical indications, clinical results and visual outcome. J Cataract Refract Surg 17 (1991) 811-818
    • (1991) J Cataract Refract Surg , vol.17 , pp. 811-818
    • Mamalis, N.1    Crandall, A.S.2    Pulsipher, M.W.3    Follett, S.4    Monson, M.C.5
  • 32
    • 0031709166 scopus 로고    scopus 로고
    • Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa
    • Hayashi K., Hayashi H., Matsuo K., Nakao F., and Hayashi F. Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa. Ophthalmology 105 (1998) 1239-1243
    • (1998) Ophthalmology , vol.105 , pp. 1239-1243
    • Hayashi, K.1    Hayashi, H.2    Matsuo, K.3    Nakao, F.4    Hayashi, F.5
  • 33
    • 0031762312 scopus 로고    scopus 로고
    • Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome
    • Hayashi H., Hayashi K., Nakao F., and Hayashi F. Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome. Br J Ophthalmol 82 (1998) 1429-1432
    • (1998) Br J Ophthalmol , vol.82 , pp. 1429-1432
    • Hayashi, H.1    Hayashi, K.2    Nakao, F.3    Hayashi, F.4
  • 34
    • 0037363904 scopus 로고    scopus 로고
    • Contrast sensitivity and functional vision
    • Ginsburg A. Contrast sensitivity and functional vision. Int Ophthalmol Clin 43 (2003) 5-16
    • (2003) Int Ophthalmol Clin , vol.43 , pp. 5-16
    • Ginsburg, A.1
  • 36
    • 33751409274 scopus 로고    scopus 로고
    • Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations
    • Kasper T., Buhren J., and Kohnen T. Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations. J Cataract Refract Surg 32 (2006) 2022-2029
    • (2006) J Cataract Refract Surg , vol.32 , pp. 2022-2029
    • Kasper, T.1    Buhren, J.2    Kohnen, T.3
  • 37
    • 35548932511 scopus 로고    scopus 로고
    • Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses; a prospective randomized study
    • Rocha K.M., Soriano E.S., Chamon W., Chalita M.R., and Nosé W. Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses; a prospective randomized study. Ophthalmology 114 (2007) 2050-2054
    • (2007) Ophthalmology , vol.114 , pp. 2050-2054
    • Rocha, K.M.1    Soriano, E.S.2    Chamon, W.3    Chalita, M.R.4    Nosé, W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.