메뉴 건너뛰기




Volumn 3, Issue , 2009, Pages 1847-1863

Particulate matter emissions from a high-rise layer house in Iowa

Author keywords

Layer house; Particulate matter; Poultry

Indexed keywords

ANIMAL FEEDING OPERATIONS; CAGE SYSTEMS; EMISSION RATES; PARTICULATE MATTER; PARTICULATE MATTER EMISSIONS; PM10 EMISSIONS;

EID: 76549122585     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (36)
  • 1
    • 36248995613 scopus 로고    scopus 로고
    • Particulate matter emission from animal feeding operations
    • National Center for Mature and Animal Waste Management White Paper. Eds by Rice, J.M, Carldwell, D.F, Humenik, F.J, St. Joseph, Michigan: ASABE publication number 913
    • Auvermann, B., Bottcher, R., Heber, A., Meyer, D., Parnell, C.B. Jr., Shaw, B., Worley, J. 2006. Particulate matter emission from animal feeding operations. In. Animal Agriculture and the Environment. National Center for Mature and Animal Waste Management White Paper. Eds by Rice, J.M., Carldwell, D.F., Humenik, F.J. 435-468. St. Joseph, Michigan: ASABE publication number 913C0306.
    • (2006) Animal Agriculture and the Environment , Issue.C0306 , pp. 435-468
    • Auvermann, B.1    Bottcher, R.2    Heber, A.3    Meyer, D.4    Parnell Jr., C.B.5    Shaw, B.6    Worley, J.7
  • 3
    • 15244358982 scopus 로고    scopus 로고
    • Relative ammonia concentrations, dust concentrations, and presence of Salmonella species and Escherichia coli inside and outside commercial layer facilities
    • Davis, M., Morishita, T.Y. 2005. Relative ammonia concentrations, dust concentrations, and presence of Salmonella species and Escherichia coli inside and outside commercial layer facilities. Avian Diseases 49: 30-35.
    • (2005) Avian Diseases , vol.49 , pp. 30-35
    • Davis, M.1    Morishita, T.Y.2
  • 5
    • 34547751013 scopus 로고    scopus 로고
    • Ammonia, methane, nitrous oxide and particulate matter emissions from two different buildings for laying hens
    • Fabbri, C., Valli, L., Guarina, M., Costa, A., Mazzotta, V. 2007. Ammonia, methane, nitrous oxide and particulate matter emissions from two different buildings for laying hens. Biosystems Engineering 97:441-455.
    • (2007) Biosystems Engineering , vol.97 , pp. 441-455
    • Fabbri, C.1    Valli, L.2    Guarina, M.3    Costa, A.4    Mazzotta, V.5
  • 6
    • 11144296280 scopus 로고    scopus 로고
    • Fan assessment numeration systems (FANS) design and calibration specifications
    • Gates, R.S., Casey, K.D., Xin, H., Wheeler, E.F., Simmons, J.D. 2004. Fan assessment numeration systems (FANS) design and calibration specifications. Transactions of the ASABE, 47(5): 1709-1715.
    • (2004) Transactions of the ASABE , vol.47 , Issue.5 , pp. 1709-1715
    • Gates, R.S.1    Casey, K.D.2    Xin, H.3    Wheeler, E.F.4    Simmons, J.D.5
  • 7
    • 84905527808 scopus 로고    scopus 로고
    • CIGC. 1994. Aerial environment in animal housing: Concentration in and emissions from farm buildings. Working group report series No 94.1.International Commission of Agricultural Engineering. http://www.cigr.org/documents/CIGR- workinggroupreport1994.pdf
    • CIGC. 1994. Aerial environment in animal housing: Concentration in and emissions from farm buildings. Working group report series No 94.1.International Commission of Agricultural Engineering. http://www.cigr.org/documents/CIGR- workinggroupreport1994.pdf
  • 8
    • 0024700759 scopus 로고    scopus 로고
    • Glennon, C.R., McQuitty, J.B., Clark, P.C., Feddes, J.J.R. 1989. Air quality in pullet barns. Canadian Agric. Engng 31(2): 233-237.
    • Glennon, C.R., McQuitty, J.B., Clark, P.C., Feddes, J.J.R. 1989. Air quality in pullet barns. Canadian Agric. Engng 31(2): 233-237.
  • 9
    • 0033169143 scopus 로고    scopus 로고
    • Dust concentration and mortality distribution in an enclosed laying house
    • Guarino, M., Caroli, A., Navarotto, P. 1999. Dust concentration and mortality distribution in an enclosed laying house. Trans. ASAE 42(4): 1127-1133.
    • (1999) Trans. ASAE , vol.42 , Issue.4 , pp. 1127-1133
    • Guarino, M.1    Caroli, A.2    Navarotto, P.3
  • 11
    • 0000919544 scopus 로고    scopus 로고
    • A comprehensive experimental study of aerial pollutions in and emissions from livestock buildings. part 1: Methods
    • Hinz, T., Linke, S. 1998a. A comprehensive experimental study of aerial pollutions in and emissions from livestock buildings. part 1: methods. J. of Agric. Engng Res. 70: 111-118.
    • (1998) J. of Agric. Engng Res , vol.70 , pp. 111-118
    • Hinz, T.1    Linke, S.2
  • 12
    • 11544311961 scopus 로고    scopus 로고
    • A comprehensive experimental study of aerial pollutions in and emissions from livestock buildings. part 2: Results
    • Hinz, T., Linke, S. 1998b. A comprehensive experimental study of aerial pollutions in and emissions from livestock buildings. part 2: results. J. of Agric. Engng Res. 70: 119-129.
    • (1998) J. of Agric. Engng Res , vol.70 , pp. 119-129
    • Hinz, T.1    Linke, S.2
  • 14
    • 0021451646 scopus 로고    scopus 로고
    • Leonard, J.J., Feddes, J.J.R., McQuitty, J.B. 1984. Air quality in commercial broiler housing. Canadian Agric. Engng 26(1): 65-71.
    • Leonard, J.J., Feddes, J.J.R., McQuitty, J.B. 1984. Air quality in commercial broiler housing. Canadian Agric. Engng 26(1): 65-71.
  • 15
    • 84905531482 scopus 로고    scopus 로고
    • Li, H., Xin, H., Burns, R., Hoff, S., Harmon, J., Jacobson, L., Noll, S., Koziel, J. 2008. Ammonia and PM emissions from a torn turkey barn in Iowa. ASAE3E Paper No. 084425. St. Joseph, Mich.: ASABE.
    • Li, H., Xin, H., Burns, R., Hoff, S., Harmon, J., Jacobson, L., Noll, S., Koziel, J. 2008. Ammonia and PM emissions from a torn turkey barn in Iowa. ASAE3E Paper No. 084425. St. Joseph, Mich.: ASABE.
  • 16
    • 84905537286 scopus 로고    scopus 로고
    • Lim, T.T., Heber, A.J., Ni, J.Q., Gallien, J.X., Xin, H. 2003. Air quality measurement at a laying hen house: particulate matter concentration and emissions. In Air Pollution from Agricultural Operations III, 249-256. H. Keener ed., ASABE Publication no. 701P1043, St. Joseph, Mich.: ASABE.
    • Lim, T.T., Heber, A.J., Ni, J.Q., Gallien, J.X., Xin, H. 2003. Air quality measurement at a laying hen house: particulate matter concentration and emissions. In Air Pollution from Agricultural Operations III, 249-256. H. Keener ed., ASABE Publication no. 701P1043, St. Joseph, Mich.: ASABE.
  • 17
    • 36249013292 scopus 로고
    • Field tests of a particulate impaction curtain on emissions from a high-rise layer barn
    • Lim, T.T., Sun, H., Ni, J.Q., Zhao, L., Diehl, C.A., Heber, A.J., Hanni, S.M. 2007. Field tests of a particulate impaction curtain on emissions from a high-rise layer barn. Trans. ASABE 50(5): 1795.
    • (1795) Trans. ASABE , vol.50 , Issue.5
    • Lim, T.T.1    Sun, H.2    Ni, J.Q.3    Zhao, L.4    Diehl, C.A.5    Heber, A.J.6    Hanni, S.M.7
  • 18
    • 0031268431 scopus 로고    scopus 로고
    • Air quality in a multiple tier rearing system for layer type pullets
    • Martensson, L., Pehrson, C. 1997. Air quality in a multiple tier rearing system for layer type pullets. J. Agric. Safety and Health 3(4): 217-228.
    • (1997) J. Agric. Safety and Health , vol.3 , Issue.4 , pp. 217-228
    • Martensson, L.1    Pehrson, C.2
  • 19
    • 0022035079 scopus 로고    scopus 로고
    • McQuitty, J.B., Feddes, J.J.R., Leonard, J.J. 1985. Air quality in commercial layer barns. Canadian Agric. Engng 27(1): 13-19.
    • McQuitty, J.B., Feddes, J.J.R., Leonard, J.J. 1985. Air quality in commercial layer barns. Canadian Agric. Engng 27(1): 13-19.
  • 20
    • 1842429934 scopus 로고    scopus 로고
    • Application of an electrostatic space charge system for dust, ammonia, and pathogen reduction in a broiler breeder house
    • Mitchell, B.W., Richardson, L.J., Wilson, J.L., Hofacre, C.L. 2004. Application of an electrostatic space charge system for dust, ammonia, and pathogen reduction in a broiler breeder house. Appl. Eng. in Agric. 20(1): 87-93.
    • (2004) Appl. Eng. in Agric , vol.20 , Issue.1 , pp. 87-93
    • Mitchell, B.W.1    Richardson, L.J.2    Wilson, J.L.3    Hofacre, C.L.4
  • 21
    • 84905553754 scopus 로고    scopus 로고
    • Muhlbauer, R.V., T. A. Shepherd, H. Li, R.T. Burns, H. Xin. 2006. Development and testing of a fan monitoring system using induction operated current switches. ASABE paper no. 064159, St. Joseph, Ml: ASABE.
    • Muhlbauer, R.V., T. A. Shepherd, H. Li, R.T. Burns, H. Xin. 2006. Development and testing of a fan monitoring system using induction operated current switches. ASABE paper no. 064159, St. Joseph, Ml: ASABE.
  • 23
    • 0008025610 scopus 로고
    • Airborne dust concentrations in livestock buildings and the effect of feed
    • Pearson, C.C., Sharpies, T.J. 1995. Airborne dust concentrations in livestock buildings and the effect of feed. J. Agric. Engng Res. 60: 145-154.
    • (1995) J. Agric. Engng Res , vol.60 , pp. 145-154
    • Pearson, C.C.1    Sharpies, T.J.2
  • 24
    • 0026916298 scopus 로고
    • Dust net generation rate in a poultry layer house
    • Qi, R., Manbeck, H.B., Maghirang, R.G. 1992. Dust net generation rate in a poultry layer house. Trans. ASAE 35(5): 1639-1645.
    • (1992) Trans. ASAE , vol.35 , Issue.5 , pp. 1639-1645
    • Qi, R.1    Manbeck, H.B.2    Maghirang, R.G.3
  • 25
    • 0036665346 scopus 로고    scopus 로고
    • Concentration and emissions of ammonia and particulate matter in tunnel-ventilated broiler houses under summer conditions in Texas
    • Redwine, J.S., Lacey, R.E., Mukhtar, S., Carey, J.B. 2002. Concentration and emissions of ammonia and particulate matter in tunnel-ventilated broiler houses under summer conditions in Texas. Trans. ASAE 45(4): 1101-1109.
    • (2002) Trans. ASAE , vol.45 , Issue.4 , pp. 1101-1109
    • Redwine, J.S.1    Lacey, R.E.2    Mukhtar, S.3    Carey, J.B.4
  • 26
    • 33745678015 scopus 로고    scopus 로고
    • Improving in-house air quality in broiler production facilities using an electrostatic space charge system
    • Ritz, C.W., Mitchell, B.W., Fairchild, B.D., Czarick, M.III, Worley, J.W. 2006. Improving in-house air quality in broiler production facilities using an electrostatic space charge system. J. Appl. Poult. Res. 15: 333-340.
    • (2006) J. Appl. Poult. Res , vol.15 , pp. 333-340
    • Ritz, C.W.1    Mitchell, B.W.2    Fairchild, B.D.3    Czarick III, M.4    Worley, J.W.5
  • 27
    • 34447107109 scopus 로고    scopus 로고
    • Size fractionated particulate matter emissions from a broiler house in Southern Ontario, Canada
    • Roumelios, T.S., Van Heyst, B.J. 2007. Size fractionated particulate matter emissions from a broiler house in Southern Ontario, Canada. Science of the Total Environment 383: 174-182.
    • (2007) Science of the Total Environment , vol.383 , pp. 174-182
    • Roumelios, T.S.1    Van Heyst, B.J.2
  • 29
    • 0023982363 scopus 로고
    • Respirable aerosol concentrations in enclosed laying houses
    • Van Wicklen, G.L., Yoder, M.F., David, B.D. 1988. Respirable aerosol concentrations in enclosed laying houses. Trans. ASAE 31(2): 546-551.
    • (1988) Trans. ASAE , vol.31 , Issue.2 , pp. 546-551
    • Van Wicklen, G.L.1    Yoder, M.F.2    David, B.D.3
  • 30
    • 2042535105 scopus 로고
    • Aerosol and ammonia concentrations in broiler house using mechanical and natural ventilation
    • Van Wichlen, G.L., Allison, J.M. 1989. Aerosol and ammonia concentrations in broiler house using mechanical and natural ventilation. J. Agric. Engng Res. 42:97-109.
    • (1989) J. Agric. Engng Res , vol.42 , pp. 97-109
    • Van Wichlen, G.L.1    Allison, J.M.2
  • 32
    • 34249904149 scopus 로고    scopus 로고
    • The effect of animal age on air pollutant concentration in a broiler house
    • Vucemilo, M., Katkovic, K., Vinkovic, B., Jaksic, S., Granic, K., Mas, N. 2007. The effect of animal age on air pollutant concentration in a broiler house. Czech J. Anim. Sci. 52(6): 170-174.
    • (2007) Czech J. Anim. Sci , vol.52 , Issue.6 , pp. 170-174
    • Vucemilo, M.1    Katkovic, K.2    Vinkovic, B.3    Jaksic, S.4    Granic, K.5    Mas, N.6
  • 33
    • 0031089550 scopus 로고    scopus 로고
    • Concentrations and emissions rates of aerial ammonia, nitrous oxide, methane, carbon dioxide, dust and endotoxin in UK broiler and layer houses
    • Wathes, C.M., Holden, M.R., Sneath, R.W., White, R.P., Phillips, V.R. 1997. Concentrations and emissions rates of aerial ammonia, nitrous oxide, methane, carbon dioxide, dust and endotoxin in UK broiler and layer houses. British Poultry Science 38: 14-28.
    • (1997) British Poultry Science , vol.38 , pp. 14-28
    • Wathes, C.M.1    Holden, M.R.2    Sneath, R.W.3    White, R.P.4    Phillips, V.R.5
  • 34
    • 0024069207 scopus 로고
    • Respirable aerosol generation by broiler chickens
    • Yoder, M.F., Wicklen, G.L.V. 1988. Respirable aerosol generation by broiler chickens. Trans. ASAE 51(5): 1510-1517.
    • (1988) Trans. ASAE , vol.51 , Issue.5 , pp. 1510-1517
    • Yoder, M.F.1    Wicklen, G.L.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.