메뉴 건너뛰기




Volumn 13, Issue 1, 2010, Pages 29-35

Some Physical and Clinical Factors Influencing the Measurement of Precision Error, Least Significant Change, and Bone Mineral Density in Dual-Energy X-Ray Absorptiometry

Author keywords

Bone mineral density; DXA; least significant change; precision error

Indexed keywords

ARTICLE; BONE DENSITY; CLASSIFICATION ALGORITHM; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FOLLOW UP; HIP; HUMAN; LEAST SIGNIFICANT CHANGE; LUMBAR SPINE; MEASUREMENT; MEASUREMENT ERROR; PHANTOM; PRIORITY JOURNAL;

EID: 76449093740     PISSN: 10946950     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jocd.2009.09.004     Document Type: Article
Times cited : (9)

References (12)
  • 2
    • 42649112056 scopus 로고    scopus 로고
    • Official positions of the International Society for Clinical Densitometry and executive summary of the 2007 ISCD Position Development Conference
    • Baim S., Binkley N., Bilezikian J.R., et al. Official positions of the International Society for Clinical Densitometry and executive summary of the 2007 ISCD Position Development Conference. J Clin Densitom 11 (2008) 75-91
    • (2008) J Clin Densitom , vol.11 , pp. 75-91
    • Baim, S.1    Binkley, N.2    Bilezikian, J.R.3
  • 3
    • 0032843415 scopus 로고    scopus 로고
    • Accuracy and precision of 62 bone densitometers using a European Spine Phantom
    • Kolta S., Ravaud P., Fechtenbaum J., et al. Accuracy and precision of 62 bone densitometers using a European Spine Phantom. Osteoporos Int 10 (1999) 14-19
    • (1999) Osteoporos Int , vol.10 , pp. 14-19
    • Kolta, S.1    Ravaud, P.2    Fechtenbaum, J.3
  • 4
    • 18644370260 scopus 로고    scopus 로고
    • Standards and guidelines for performing central dual X-ray densitometry from the Canadian panel of international society for clinical densitometry
    • Khan A.A., Brown J., Faulkner K., et al. Standards and guidelines for performing central dual X-ray densitometry from the Canadian panel of international society for clinical densitometry. J Clin Densitom 5 (2002) 435-445
    • (2002) J Clin Densitom , vol.5 , pp. 435-445
    • Khan, A.A.1    Brown, J.2    Faulkner, K.3
  • 6
    • 33644878009 scopus 로고    scopus 로고
    • Precision assessment and radiation safety for dual-energy X-ray absorptiometry
    • Baim S., Wilson C.R., Lewiecki E.M., et al. Precision assessment and radiation safety for dual-energy X-ray absorptiometry. J Clin Densitom 8 (2005) 371-378
    • (2005) J Clin Densitom , vol.8 , pp. 371-378
    • Baim, S.1    Wilson, C.R.2    Lewiecki, E.M.3
  • 7
    • 33744900335 scopus 로고    scopus 로고
    • The importance of spectrum bias on bone density monitoring in clinical practice
    • Leslie W. The importance of spectrum bias on bone density monitoring in clinical practice. Bone 39 (2006) 361-368
    • (2006) Bone , vol.39 , pp. 361-368
    • Leslie, W.1
  • 8
    • 4444238223 scopus 로고    scopus 로고
    • Bone density monitoring with the total hip site
    • for the Manitoba Bone Density Program
    • Leslie W.D., Ward L.M., and for the Manitoba Bone Density Program. Bone density monitoring with the total hip site. J Clin Densitom 7 (2004) 269-274
    • (2004) J Clin Densitom , vol.7 , pp. 269-274
    • Leslie, W.D.1    Ward, L.M.2
  • 9
    • 0038280029 scopus 로고    scopus 로고
    • Need for precision studies at individual institutions and assessment of size of regions of interest on serial DXA scans
    • Morgan S.L., Abercrombie W., and Lee J.Y. Need for precision studies at individual institutions and assessment of size of regions of interest on serial DXA scans. J Clin Densitom 6 (2003) 97-101
    • (2003) J Clin Densitom , vol.6 , pp. 97-101
    • Morgan, S.L.1    Abercrombie, W.2    Lee, J.Y.3
  • 10
    • 0031665623 scopus 로고    scopus 로고
    • Linearity and accuracy errors in bone densitometry
    • Nielsen S.P., Barenholdt O., Diessel E., et al. Linearity and accuracy errors in bone densitometry. Br J Radiol 71 (1998) 1062-1068
    • (1998) Br J Radiol , vol.71 , pp. 1062-1068
    • Nielsen, S.P.1    Barenholdt, O.2    Diessel, E.3
  • 11
    • 34247574442 scopus 로고    scopus 로고
    • Effect of percision error on T-scores and the diagnostic classification of bone status
    • Kiebzak G.M., Faulkner K.M., Wacker W., et al. Effect of percision error on T-scores and the diagnostic classification of bone status. J Clin Densitom 10 (2007) 239-243
    • (2007) J Clin Densitom , vol.10 , pp. 239-243
    • Kiebzak, G.M.1    Faulkner, K.M.2    Wacker, W.3
  • 12
    • 55249086075 scopus 로고    scopus 로고
    • QA/acceptance testing of DEXA X-ray systems used in bone mineral densitometry
    • Larkin A., Sheahan N., O'Connor U., et al. QA/acceptance testing of DEXA X-ray systems used in bone mineral densitometry. Rad Prot Dosim 129 (2008) 279-283
    • (2008) Rad Prot Dosim , vol.129 , pp. 279-283
    • Larkin, A.1    Sheahan, N.2    O'Connor, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.