Erosion of the spinous process: A potential cause of interspinous process spacer failure - Report of 2 cases

Author keywords

Interspinous process spacer; Lumbar spinal stenosis; Neurogenic claudication; Spinous process erosion

Indexed keywords

ADULT; AGED; ANAMNESIS; ARTICLE; CASE REPORT; CLAUDICATION; CLINICAL FEATURE; FEMALE; HISTOPATHOLOGY; HUMAN; INTERSPINOUS PROCESS SPACER; INTERVERTEBRAL DISKECTOMY; MALE; MEDICAL EXAMINATION; MOTION; NEUROGENIC CLAUDICATION; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTOPERATIVE COMPLICATION; RECURRENT DISEASE; SPINAL CORD DECOMPRESSION; SPINOUS PROCESS EROSION; SURGICAL INSTRUMENT; TREATMENT FAILURE; VERTEBRAL CANAL STENOSIS;

EID: 76149102609     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2009.9.SPINE09144     Document Type: Article
Times cited : (20)

References (17)
  • 1
    • 33745963645 scopus 로고    scopus 로고
    • Treatment of neurogenic claudication by interspinous decompression: Application of the X-Stop device in patients with lumbar degenerative spondylolisthesis
    • Anderson PA, Tribus CB, Kitchel SH: Treatment of neurogenic claudication by interspinous decompression: application of the X-Stop device in patients with lumbar degenerative spondylolisthesis. J Neurosurg Spine 4:463-471, 2006
    • (2006) J Neurosurg Spine , vol.4 , pp. 463-471
    • Anderson, P.A.1    Tribus, C.B.2    Kitchel, S.H.3
  • 2
    • 39049168729 scopus 로고    scopus 로고
    • Selfrated evaluation of outcome of the implantation of interspinous process distraction (X-Stop) for neurogenic claudication
    • Brussee P, Hauth J, Donk RD, Verbeek AL, Bartels RH: Selfrated evaluation of outcome of the implantation of interspinous process distraction (X-Stop) for neurogenic claudication. Eur Spine J 17:200-203, 2008
    • (2008) Eur Spine J , vol.17 , pp. 200-203
    • Brussee, P.1    Hauth, J.2    Donk, R.D.3    Verbeek, A.L.4    Bartels, R.H.5
  • 3
    • 64849107678 scopus 로고    scopus 로고
    • X-Stop: Foot drop
    • Epstein NE: X-Stop: foot drop. Spine J 9:e6-e9, 2008
    • (2008) Spine J , vol.9
    • Epstein, N.E.1
  • 4
    • 0027933091 scopus 로고
    • Cross sectional area of the stenotic lumbar dural tube measured from the transverse views of the magnetic resonance imaging
    • Hamanashi C, Matukura N, Fujita M, Tomihara M, Tanaka S: Cross sectional area of the stenotic lumbar dural tube measured from the transverse views of the magnetic resonance imaging. J Spinal Disord 7:388-393, 1994
    • (1994) J Spinal Disord , vol.7 , pp. 388-393
    • Hamanashi, C.1    Matukura, N.2    Fujita, M.3    Tomihara, M.4    Tanaka, S.5
  • 5
    • 0036870247 scopus 로고    scopus 로고
    • Microendoscopic decompressive laminotomy for the treatment of lumbar stenosis
    • Khoo LT, Fessler RG: Microendoscopic decompressive laminotomy for the treatment of lumbar stenosis. Neurosurgery 51 (5 Suppl):S146-S154, 2002
    • (2002) Neurosurgery , vol.51 , Issue.5 SUPPL.
    • Khoo, L.T.1    Fessler, R.G.2
  • 6
    • 33747839684 scopus 로고    scopus 로고
    • Interspinous process decompression with the X-Stop device for lumbar spinal stenosis: A 4-year follow up study
    • Kondrashov DG, Hannibal M, Hsu KY, Zuckerman JF: Interspinous process decompression with the X-Stop device for lumbar spinal stenosis: a 4-year follow up study. J Spinal Disord Tech 19:323-327, 2006
    • (2006) J Spinal Disord Tech , vol.19 , pp. 323-327
    • Kondrashov, D.G.1    Hannibal, M.2    Hsu, K.Y.3    Zuckerman, J.F.4
  • 7
    • 34547409959 scopus 로고    scopus 로고
    • Appropriate selection of patients with lumbar stenosis for interspinous process decompression with the XStop device
    • Lauryssen C: Appropriate selection of patients with lumbar stenosis for interspinous process decompression with the XStop device. Neurosurg Focus 22(1):E5, 2007
    • (2007) Neurosurg Focus , vol.22 , Issue.1
    • Lauryssen, C.1
  • 8
    • 0141557694 scopus 로고    scopus 로고
    • The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine
    • Lindsey DP, Swanson KE, Fuchs P, Hsu KY, Zucherman JF, Yerby SA: The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine. Spine 28:2192-2197, 2003
    • (2003) Spine , vol.28 , pp. 2192-2197
    • Lindsey, D.P.1    Swanson, K.E.2    Fuchs, P.3    Hsu, K.Y.4    Zucherman, J.F.5    Yerby, S.A.6
  • 9
    • 16844369978 scopus 로고    scopus 로고
    • The treatment mechanism of an interspinous process implant for lumbar neurogenic claudication
    • Richards JC, Majumdar S, Lindsey DP, Deaupre GS, Yerby SA: The treatment mechanism of an interspinous process implant for lumbar neurogenic claudication. Spine 30:744-749, 2005
    • (2005) Spine , vol.30 , pp. 744-749
    • Richards, J.C.1    Majumdar, S.2    Lindsey, D.P.3    Deaupre, G.S.4    Yerby, S.A.5
  • 10
    • 0023787686 scopus 로고
    • Pressure changes following constriction of the cauda equina. An experimental study in situ
    • Schönström N, Hansson T: Pressure changes following constriction of the cauda equina. An experimental study in situ. Spine (Phila Pa 1976) 4:385-388, 1988
    • (1976) Spine (Phila Pa , vol.4
    • Schönström, N.1    Hansson, T.2
  • 12
    • 0001004330 scopus 로고
    • A radicular syndrome from developmental narrowing of the lumbar vertebral canal
    • Verbiest H: A radicular syndrome from developmental narrowing of the lumbar vertebral canal. J Bone Joint Surg Br 36:230-237, 1954
    • (1954) J Bone Joint Surg Br , vol.36 , pp. 230-237
    • Verbiest, H.1
  • 13
    • 38849157767 scopus 로고    scopus 로고
    • High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis
    • Verhoof OJ, Bron JL, Wapstra FH, van Royen BJ: High failure rate of the interspinous distraction device (X-Stop) for the treatment of lumbar spinal stenosis caused by degenerative spondylolisthesis. Eur Spine J 17:188-192, 2008
    • (2008) Eur Spine J , vol.17 , pp. 188-192
    • Verhoof, O.J.1    Bron, J.L.2    Wapstra, F.H.3    van Royen, B.J.4
  • 14
    • 49249109406 scopus 로고    scopus 로고
    • Biomechanical effect of different interspinous implants on flexibility and intradiscal pressure
    • Wilke HJ, Drumm J, Haussler K, Mack C, Steudel WI, Kettler A: Biomechanical effect of different interspinous implants on flexibility and intradiscal pressure. Eur Spine J 17:1049-1056, 2008
    • (2008) Eur Spine J , vol.17 , pp. 1049-1056
    • Wilke, H.J.1    Drumm, J.2    Haussler, K.3    Mack, C.4    Steudel, W.I.5    Kettler, A.6
  • 15
    • 0031428991 scopus 로고    scopus 로고
    • Dynamic effects on the lumbar spinal canal: Axially loaded CT-myelography and MRI in patients with sciatica and/or neurogenic claudication
    • Willen J, Danielson B, Gaulitz A, Niklason T, Schonstrom N, Hansson T: Dynamic effects on the lumbar spinal canal: Axially loaded CT-myelography and MRI in patients with sciatica and/or neurogenic claudication. Spine (Phila Pa 1976) 22: 2968-2976, 1997
    • (1997) Spine (Phila Pa 1976) 22 , pp. 2968-2976
    • Willen, J.1    Danielson, B.2    Gaulitz, A.3    Niklason, T.4    Schonstrom, N.5    Hansson, T.6
  • 17
    • 0023757140 scopus 로고
    • Relief of lumbar canal stenosis using multilevel subarticular fenestration as an altenative to wide laminectomy. Preliminary report
    • Young S, Veerapen R, O'Laoire SA: Relief of lumbar canal stenosis using multilevel subarticular fenestration as an altenative to wide laminectomy. Preliminary report. Neurosurgery 23:628-633, 1988
    • (1988) Neurosurgery , vol.23 , pp. 628-633
    • Young, S.1    Veerapen, R.2    O'Laoire, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.